USER’S INFORMA TION MANU AL MODEL 340MA V , 350MA V , 352MA V , 355MA V CONDENSING GAS FURN A CE — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHA T T O DO IF YOU SMELL GAS: — Do not try to light any appliance.
INST ALLA TION D A T A Date Installed Dealer Name Address City State Zip T elephone FURNA CE Product No . Model No . Serial No . SPLIT -SYSTEM OUTDOOR UNIT: Product No .
3 FURN A CE COMPONENTS Combustion-air intake connection to ensure contaminant-free air (right or left side). Burner sight glass for viewing burner flame. Burner assembly (inside). Operates with energy- saving inshot burners and hot surface ignitor for safe, dependable heating.
4 IMPOR T ANT F A CTS Y our gas furnace uses air from outside the home for combustion and venting. It is not to be installed using in-house air . Therefore, both pipes must terminate outside the structure and must not be obstructed in any w ay .
5 a 8 9 10 2. Close the external manual g as v alve. (See Fig. 9.) 3. T urn of f electrical supply to the furnace. (See Fig. 10.) 4. Remov e the main furnace door . (See Fig. 11.) 5. Gas valve will ha ve EITHER a con- trol switch or control knob to turn OFF or ON.
6 16 17 18 SHUTTING DO WN Y OUR FURN A CE Should you need to shut do wn your furnace for service or maintenance, you will need to turn the furnace of f. 19 O P E N ® 20 The follo wing procedures must be follo wed: 1. Set your room thermostat to the lo west temperature setting.
7 BLO WER COMP AR TMENT a. Remo ve main furnace door . (See Fig. 23) b . Remove blo wer access panel. (See Fig. 24) NO TE: It will be necessary to remov e 2 screws • AIR FIL TER LOCA TED IN FIL- TER CABINET a. Remo ve fi lter cabinet door (See Fig.
8 29 30 COMBUSTION AREA AND VENT SYSTEM V isually inspect the combustion area and vent system before each heating season. Make sure that all PVC pipes leading into the comb ustion area and vent are free from an y cracks and sags. Also check the comb ustion-air intake and vent pipes on the outside of your home for blockage.
9 34 35 7. Pour 1 quart of antifreeze into funnel/tube. Antifreeze should run through inducer housing, over fi ll condensate trap, and fl ow into open fi eld drain. (See Fig. 35.) 8. Remov e funnel and tube from inducer housing and replace drain connection cap and clamp.
10 39 40 41 BEFORE Y OU REQUEST A SER VICE CALL If your furnace is not operating or not performing properly , you may sav e the expense of a service call by check- ing a fe w things yourself before calling for service. FOR INSUFFICIENT AIRFLOW : • Check for dirty air fi lter(s).
11 MODEL 340MA V AND 350MA V DIA GNOSTIC CHAR T (See Fig. 3.) NO TES: 1. Light on continuously means control has po wer and working properly . 2. The fault code is a 2-digit n umber . The fi rst digit is determined by the number of short fl ashes of the light and the second digit is determined by number of long fl ashes of the light.
Cancels: OM05-30 OM05-32 © 2001 Bryant Heating & Cooling Systems, 7310 W . Morris St., Indpls., IN 46231 12 Printed in U.S .A. Catalog No . 5335-202 3-01 MODEL 355MA V DIA GNOSTIC CHAR T (See Fig. 4.) NO TES: 1. Red light 1 on continuously means furnace is operating in emergency heat.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bryant CONDENSING GAS FURNACE 340MAV è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bryant CONDENSING GAS FURNACE 340MAV - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bryant CONDENSING GAS FURNACE 340MAV imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bryant CONDENSING GAS FURNACE 340MAV ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bryant CONDENSING GAS FURNACE 340MAV, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bryant CONDENSING GAS FURNACE 340MAV.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bryant CONDENSING GAS FURNACE 340MAV. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bryant CONDENSING GAS FURNACE 340MAV insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.