Manuale d’uso / di manutenzione del prodotto 619FNQ del fabbricante Bryant
Vai alla pagina of 24
Cancels: New II 619F-18-1 4/1/06 installation, star t-up and serv ice instructions IN-CEILING CASSETTE F AN COIL UNITS 619FNF 619FNQ Sizes 018-03036 CONTENTS Page SAFETY CONSIDERA TIONS . . . . . . . . . . . . . . . . . . . . . . . . . 1 GENERAL . . .
—2— INST ALLA TION I. STEP 1 — COMPLETE PRE-INST ALLA TION CHECKS A. Unpack Unit (See Fig. 1) Move the unit to final location. The gril le panel and the remote control are packed separat ely for maximum protec- tion.
—3— 2'-4-11/32"(720) 1'-9-21/32"(550) ) 5 1 5 ( " 2 3 / 9 8 - ' 1 1-7/8"(47) 1'-1 1-7/16"(595) ) 3 1 8 ( " 8 - ' 2 ) 0 6 9 ( " 4 6 / 1 5.
—4— T able 4A — 619FNF Physical Data LEGEND *See T ab le 3 for f actory charge and additional field charge requirements. SYSTEM SIZE 018 024 030 036 NOMINAL CAP ACITY (Btuh) 17,000 23,600 29,000.
—5— T able 4B — 619FNQ Physical Data LEGEND *See T able 3 for f actory charge and additio nal field charge requirements. SYSTEM SIZE 018 024 030 036 NOMINAL CAP ACITY (Btuh) Heat Pump Cooling 17,900 2 2,600 29,200 33,400 Heating 16,800 2 0,800 27,400 32,400 Cooling with Electric Heat 17,000 22,600 29,000 36,000 SEER 13 HSPF 7.
—6— II. STEP 2 — LOCA TING AND MOU NTING THE UNIT A. Locating the Unit Install the unit as centrally as possible in the room. The air- flow direction c an be controlled by the remote control (whe re used) or automatically, accor ding to the unit operating mode (cooling or heating).
—7— The condensate may be discharged at a ma ximum height of 7 7 / 8 in. above the unit, as long as the ascending tube is verti- cal and aligned with the drainag e flange. If it is necessary to discharge the con densate from a level above 7 7 / 8 in.
—8— III. STEP 3 — LOCA TING AND MOUNTING THE ROOM CONTROLLER A. Locating the Room Controller See Fig. 14 for room controller dimensions. If the air sensor in the room controller is going to be used, the room controller should be located by co nsidering the following: • Position controller with a minimum clearance of 5 ft from the floor.
—9— B. Mounting the Roo m Controll er (Fig. 15-17) Unscrew the si de fixing screw. Open the room controller rear mounting base to expose the mount ing holes. The base can be removed to simplify mounting (snap apart carefully at hinge to separate mounting ba se from the rest of the room controller).
—10— IV . STEP 4 — COMPLETE REFRIGERANT PIPING CONNECTIONS IMPORT ANT: During unit installation ma ke the refrigerant connections first and then the el ectrical connections. If the unit is uninstalled, disconnect the electrical cables first and then the refrigerant connection s.
—11— V . STEP 5 — MAKE ELECTRICAL CONNECTIONS See Tables 6A and 6B for electrical information. A. Units With Electric He ater The unit is equipped with two thermosta ts: one with auto- matic reset and one with manual (electric) reset that can be reactivated by switching the power supply off and then back on.
—12— Room Controller Connections Ground Connection Outdoor Unit Connections Low Voltage High Voltage Power Connections Fig. 21 — 619FNF Unit Matched to 538E NF Outdoor Unit — Wiring Connection.
—13— Low V oltage High V oltage Room Controller Connections Outdoor Unit Connections Power Connections Ground Connection Fig. 22 — 619FNQ Unit Matched to 538ENF Outdoor Unit — W iring Connecti.
—14— Low V oltage High V oltage Room Controller Connections Ground Connection Outdoor Unit Connections Power Connections Fig. 23 — 61 9FNQ Unit Matched to 5 38QNF Outdoor Unit — Wiring Connect.
—15— E T T E S S A C L A B O L G 619FNF R E S N E D N O C R O O D T U O 538ENF NOTE 6 NOTE 5 NOTE 4 Y A L P S I D R I A - M T L I O C - M T " D " R A L U D O M B C P 1 L O R T N O C R E P P O C E R A B T C E N N O C S I D T I N U O T ) D E D I V O R P E L B A C E S U ( D N G .
—16— E T T E S S A C L A B O L G Q N F 619 R E S N E D N O C R O O D T U O F N E 538 NOTE 6 NOTE 5 Y A L P S I D R I A - M T L I O C - M T " D " R A L U D O M B C P 1 L O R T N O C R E P P O C E R A B T C E N N O C S I D T I N U O T ) D E D I V O R P E L B A C E S U ( D N G .
—17— E T T E S S A C L A B O L G 619FNQ R E S N E D N O C R O O D T U O 538Q NF NOTE 6 NOTE 5 Y A L P S I D R I A - M T L I O C - M T " D " R A L U D O M B C P 1 L O R T N O C R E P P O C E R A B T C E N N O C S I D T I N U O T ) D E D I V O R P E L B A C E S U ( D N G .
—18— INTERNAL CONTROL P ANEL 619FNF018 Capacitor GMC board Electric heater board (only on models with electric heater) T ransformer Holes for fixing panel in position Emergency push-button Fan con.
—19— C. Wiring the Room Controller The room controller is capable of controlling from 1 to 6 fan coil units. The total run length of the wire connecting the room controller to the fan coil units should be kept to un der 500 feet. Wire the room controller to the unit using daisy chain wiring .
—20— 4.72” (120) ØA B ØA Ø C Duct connection flange Clip 1/ 4" (6 mm) neoprene gasket Insulated flexible duct Fresh air intake Conditioned air supply to an adjacent room Polystyrene part.
—21— III. R OOM CONTROLLER CONFIGURA TION SETUP To configure the room controll er, press the Mode button for 5 seconds. After 5 sec onds, “10” will appear. This indi cates that the user is setting the fi rst software configurat ion item. To display the value of config uration item 10, press the Mode button again.
—22— T able 8 — Modular Platform D Unit Config uration V alues Only the current value being di splayed is transmitted. Once the Fan button is pressed, the room controller will switch to displaying the configuration it em number. To mo ve to the next setting, press the Mode button a gain and the “20” will be displayed.
—23— 4. Ensure t hat the filt ers and return air grilles h ave been installed and that the discharge lo uvers are correctly positioned. SER VICE AND MAINTENANCE Remove unit grille, filter, an d condensa te pan for cleaning, lubricating, or replacing parts.
Copy right 2006 Bryant Heating & Cooling Systems Printed in U .S.A. CA T ALOG NO . 02-619F0001-II Green LED Red LED Y ellow LED Remote control signal receiver Emergency Button Fig.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bryant 619FNQ è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bryant 619FNQ - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bryant 619FNQ imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bryant 619FNQ ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bryant 619FNQ, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bryant 619FNQ.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bryant 619FNQ. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bryant 619FNQ insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.