352AAV 4-Way Multipoise Two-Stage Condensing Gas Furnace Sizes 060 thru 120 Product Data A05085 Utilizing the extensive resources available to Bryant, a new stan- dard of excellence has been achieved with the model 352AAV Plus 90t TM 4-Way Multipoise Furnace.
—2— 352AAV A05070 NO TE S : 1. Minim u m ret u rn- a ir opening s a t f u rn a ce, bas ed on met a l d u ct. If fle x d u ct i s us ed, s ee flex d u ct m a n u f a ct u rerí s recommend a tion s f or e qu iv a lent di a meter s . 2. Minim u m ret u rn - a ir opening a t f u rn a ce: a .
—3— 352AAV Non-Programmable Thermostat Selection * Model HP and 2S thermostat must be field converted to air conditioner operation. **Thermidistat Control is versatile and can be configured for multiple use and staging, it must be configured for each specific application.
—4— 352AAV SPECIFICATIONS See notes on page 5. UNIT SIZE 036060 036080 048080 048100 060100 060120 RATINGS AND PERFORMANCE Input Btuh† Low 39,000 52,000 52,000 65,000 65,000 7 8 ,000 High 60,000.
—5— 352AAV SPECIFICATIONS Continued * Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 2% for each 1000 ft above sea level. In Canada, derate the unit 5% from 2000 to 4500 ft above sea level. † Capacity and AFUE in accordance with U.
—6— 352AAV COMBUSTION-AIR AND VENT PIPING FOR DIRECT VENT (2-PIPE) AND NON-DIRECT VENT (1-PIPE) APPLICATIONS MAXIMUM ALLOWABLE PIPE LENGTH (FT) ALTITUDE (FT) UNIT MAX INPUT RATE (BTUH) DIRECT VENT (2-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS TERMINATION TYPE PIPE DIA (IN.
—7— 352AAV MAXIMUM ALLOWABLE PIPE LENGTH (FT) (CONTINUED) ALTITUDE (FT) UNIT MAX INPUT RATE (BTUH) DIRECT VENT (2-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS TERMINATION TYPE PIPE DIA (IN.
— 8 — 352AAV COMBUSTION-AIR AND VENT PIPING FOR DIRECT VENT (2-PIPE) AND NON-DIRECT VENT (1-PIPE) APPLICATIONS continued MAXIMUM ALLOWABLE PIPE LENGTH (FT) (CONTINUED) ALTITUDE (FT) UNIT SIZE (BTUH) DIRECT VENT (2-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS TERMINATION TYPE PIPE DIA (IN.
—9— 352AAV MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH AND WITHOUT INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT * * Pipe length (ft) specified f or maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total allowab le pipe length as specified in T able 6.
—1 0— 352AAV CONDENSATE TRAP A93026 1 ⁄ 2 OD INDUCER HOUSING DRAIN CONNECTION 1 ⁄ 4 OD COLLECTOR BOX TO TRAP RELIEF PORT 5 ⁄ 8 OD COLLECTOR BOX DRAIN CONNECTION 1 ⁄ 2 -IN.
—1 1— 352AAV ACCESSORIES CONCENTRIC VENT FOR DIRECT VENT (2-PIPE) APPLICATION (ALL MODEL SIZES) A97110 DIMENSIONS (In.) * Dimension A will change accordingly as dimension D is lengthened or shortened. †Dimension D may be lengthened to 60 in. maximum.
—1 2— 352AAV AIR DELIVERY—CFM (With Filter) • Airflow shown is with factory supplied 1-in. washable filter. • A filter is required for each return air opening. • An airflow reduction of up to 7% may occur when using the factory-specified 4-5/16-inch wide, high efficiency media filter.
—1 3— 352AAV ELECTRONIC AIR CLEANER HUMIDIFIER A/C COIL VENT COMBU S TION AIR (DIRECT VENT/ 2 PIPE APPLICATION OUTDOOR UNIT AIRFLOW FRONT OF FURNACE A05065 COMBU S TION AIR INLET (NON-DIRECT VENT/.
—1 4— 352AAV COMBU S TION–AIR PIPE ELECTRONIC AIR CLEANER FURNACE CONDEN S ATE DRAIN REFRIGERATION PIPING AIR CONDITIONING COIL AIRFLOW VENT PIPE FRONT OF FURNACE A05066 DIRECT VENT/2-PIPE APPLI.
—1 5— 352AAV.
— 16 — ©Bryant Heating & Cooling systems 7310 W. Morris St. Indianapolis, IN 46231 Printed in U.S.A. edition date: 09/09 Catalog No. PDS 352A.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.