NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS SAFETY CONSIDERATIONS .....................................................1 INTRODUCTION ....................................................................
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. INTRODUCTION These instructions are written for the Gas-Fired Induced Combus- tion Furnace. ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS PROCEDURE CAUTION: Electrostatic discharge can affect electronic components.
b. Remove filter cabinet door. c. Slide filter out of cabinet. d. If equipped with permanent, washable filter, clean filter by spraying cold tap water through filter in opposite direction of airflow. Rinse filter and let dry. Oiling or coating of the filter is not recommended.
WARNING: Blower access door switch opens 115-v power to control center. No component operation can occur. Caution must be taken when manually closing this switch for service purposes. Failure to follow this warn- ing could result in electrical shock, personal injury, or death.
(5.) Repeat foregoing procedures until each cell in furnace has been cleaned. (6.) Using vacuum cleaner, remove residue from each cell. (7.) Using vacuum cleaner with soft brush attachment, clean burner assembly. (8.) Reinstall cell inlet plates and burner assembly.
The 24-v circuit contains an automotive-type, 3-amp fuse located on the control. (See Fig. 6.) Any shorts of the 24-v wiring during installation, service, or maintenance will cause this fuse to blow. If fuse replacement is required, use ONLY a 3-amp fuse.
Fig. 7—Unit Wiring Diagram A00304 PCB BLOWER OFF DELAY SELECTION CHART 90 SEC 135 SEC 180 SEC 225 SEC GVR H I/L O RELA Y SEC-1 SEC-2 PL1 3 2 1 6 5 4 9 87 LED TEST/TWIN BLOWER OFF DELAY G R Y W C HUM HSI R I DR BL WR BLOWER SPEED SELECT FU1 COO L HEA T L2 PL3 PL2 VA C 120 L1 PR1 1 2 1 2 3 PR2 24 VAC -3A FUS E SP ARE-2 SP ARE-1 EAC-1 EAC-2 C 1.
Fig. 8—Service Label A99233 SER VICE G R Y W Com HUM TEST LED LED CODE ST A TUS 24V 11 12 13 14 21 22 23 24 31 33 34 * 9 8 6 5 32 1 4 7 COMPONENT TEST NO PREVIOUS CODE - Stored status codes are erased when pow er (115V AC or 24V AC) to control is interrupted or 48 hours after each f ault is cleared.
4. If furnace is operating properly and LED indicates proper operation, replace control access door. 5. Component Test can also be initiated by performing the following: a. Remove control access door. b. Remove blower access door. c. Manually close blower access door switch.
Troubleshooting Guide A99123a Is circuit breaker closed? Close door switch and go to start. Is red LED status light on? Is door switch closed? Is red LED status light blinking rapidly without a pause? Is there 1 15v going to switch? Replace door switch.
A99123b 11 NO PREVIOUS F A UL T - Faults are erased after 48 hrs or whenever power (1 15v or 24v) is interrupted. Run system through a heating or cooling cycle to check system. 12 BLO WER ON AFTER PO WER UP (115V OR 24V) - Normal operation. Blower will run for 90 sec when furnace power is interrupted during a call for heat, R-W closed.
A94328 SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: • Unit Familiarization • Maintenanc.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bryant 393AAV è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bryant 393AAV - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bryant 393AAV imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bryant 393AAV ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bryant 393AAV, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bryant 393AAV.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bryant 393AAV. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bryant 393AAV insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.