Manuale d’uso / di manutenzione del prodotto 353AAV del fabbricante Bryant
Vai alla pagina of 22
1 353AA V Plus 90x 4 - - W ay Multipoise Condensing Gas Furnace Input Rates: 40,000 Only Pr oduct Data 4 - - W A Y MUL TIPOISE DESIGN ALLOWS MORE APPLICA TIONS A05085 A UNIQUE SEER SOLUTION The Plus 90x is an exciting addition to your product line.
2 Direct or Non- - dir ect V enting —T h e Plus 90x can be installed as a 1 pipe/Non - - Direct vent (except 140 size unit and in manufactured/mobile home installations) or 2 pipe/Direct vent furnace. All direct vent Plus 90x models can be installed in a manufactured (mobile) home when the optional kit is used.
3 12 11 6 8 10 9 7 6 4 5 2 1 13 14 18 3 15 16 17 19 20 A08421 1. Burner sight glass for viewing burner flame. 2. Burner assembly (inside), operates with energy- - sav- ing, inshot burners and hot surface igniter for safe, dependable heating. 3. Combustion- - air intake connection to ensur e contam- inant- - free air (right or left side).
4 PHYSICAL DA T A **Note: 060- - 120 Sizes are phasing out.** UNIT SIZE 036040 036060 036080 048080 060100 060120 SHIPPING WEIGHT LB. (KG) 175 (47) 182 (57) 198 (64) 205 (69) 232 261 (74) LIMIT CONTROL SPST HEA TING BLOWER CONTROL (Off Delay) Solid - - - State Time Operation BURNERS (Monoport) 2 3 4 4 5 6 GAS CONNECTION SIZE 1/2 - - - in.
5 BR Y ANT ACCESSORIES* ACCESSORIES GAS CONVERSION KIT - - - NATURAL TO PROP ANE KGANP4601ALL GAS CONVERSION KIT - - - PROP ANE TO NA TURAL KGANP3901ALL MANUF ACTURED (MOBILE) HOME KIT KGAMH0301KIT DOWNFL OW BASE (For Combustible Floors) } KGASB0301ALL VENT TERMINA TION KIT (Bracket Only for 2 Pipes) 2 - - - IN.
6 A93086 CONCENTRIC VENT (DIRECT VENT/ 2-PIPE ONLY) A concentric vent kit allows vent and combustion-air pipes to terminate through a single exit in a roof or side wall. One pipe runs inside the other allowing venting through the inner pipe and combustion air to be drawn in through the outer pipe.
7 17 5 ⁄ 16 " 24 1 ⁄ 2 " 27 9 ⁄ 16 " TYP 27 5 ⁄ 8 " 29 1 1 ⁄ 16 " TY P 30 13 ⁄ 16 " 32 5 ⁄ 8 " TY P 33 1 ⁄ 4 " TYP CONDENSA TE DRAIN TRAP LOC A TION ( AL TERN A TE UPF LO W) 7 ⁄ 8 -IN . D IA ACCESSO R Y POWER ENT R Y 7 ⁄ 8 -IN.
8 DOWNFLOW SUBBASE DIMENSIONS - - IN. (MM) FURNACE CASING WIDTH FURNACE IN DOWNFLOW APPLICATION PLENUM OPENING FL OOR OPENING HOLE NO . FOR WIDTH A D J U S T --- MENT A B C D 17-1/2 (445) Furnace with.
9 CONDENSA TE TRAP A93026 MEDIA FIL TER CABINET A Media Filter Cabinet AB 16" (406) 17" (432) 16" (406) 20" (508) 21" (533) 20" (508) 24" (610) 25" (635) 24&quo.
10 CLEARANCE T O COMBUSTIBLES 335122-201 REV . B LIT TOP A08435 353AAV.
11 PERFORMANCE DA T A EFFICIENCY UNIT SIZE 036040 036060 036080 048080 060100 060120 CAP ACITY* Direct V ent (2 - - - pipe) (Shaded capa cities are specified on the rating plate) Upflow 38000 56000 75.
12 AIR DELIVER Y—CFM (WITH F IL TER) EXTERNAL STATIC PRESSURE (in.w c) UNIT SIZE RETURN-AIR SUPPLY SPEED 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 5(Gry) 1425 1385 1350 1305 1260 1210 1165 1100 995 855 .
13 COMBUSTION - -AIR AND VENT PIPING FOR DIRECT VENT/2 - -PIPE (ALL SIZES) AND NON - - DIRECT VENT/1 - - PIPE (SIZES 040 THROUGH 120 ONL Y) APPLICA TIONS AL TITUDE FT (M ) UNIT SIZE (BTUH) DIRECT VENT (2 -PIPE) ONL Y NON-DIRECT VENT (1-PIPE) ONL Y NUMBER OF 90 ° ELBOWS TERMINATION TYPE PIPE DIA IN.
14 COMBUSTION - -AIR AND VENT PIPING FOR DIRECT VENT/2 - -PIPE (ALL SIZES) AND NON - - DIRECT VENT/1 - - PIPE (SIZES 040 TH ROUGH 120 ONL Y) APPLICA TIONS (CON’T .
15 COMBUSTION - -AIR AND VENT PIPING FOR DIRECT VENT/2 - -PIPE (ALL SIZES) AND NON - - DIRECT VENT/1 - - PIPE (SIZES 040 TH ROUGH 120 ONL Y) APPLICA TIONS (CON’T .) AL TITUDE FT (M ) UNIT SIZE (BTUH) DIRECT VENT (2 -PIPE) ONL Y NON-DIRECT VENT (1-PIPE) ONL Y NUMBER OF 90 ° ELBOWS TERMINATION TYPE PIPE DIA IN.
16 COMBUSTION - -AIR AND VENT PIPING FOR DIRECT VENT/2 - -PIPE (ALL SIZES) AND NON - - DIRECT VENT/1 - - PIPE (SIZES 040 TH ROUGH 120 ONL Y) APPLICA TIONS (CON’T .) AL TITUDE FT (M ) UNIT SIZE (BTUH) DIRECT VENT (2 -PIPE) ONL Y NON-DIRECT VENT (1-PIPE) ONL Y NUMBER OF 90 ° ELBOWS TERMINATION TYPE PIPE DIA IN.
17 COMBUSTION - -AIR AND VENT PIPING FOR DIRECT VENT/2 - -PIPE (ALL SIZES) AND NON - - DIRECT VENT/1 - - PIPE (SIZES 040 TH ROUGH 120 ONL Y) APPLICA TIONS (CON’T .) AL TITUDE FT (M ) UNIT SIZE (BTUH) DIRECT VENT (2 -PIPE) ONL Y NON-DIRECT VENT (1-PIPE) ONL Y NUMBER OF 90 ° ELBOWS TERMINATION TYPE PIPE DIA IN.
18 MAXIMUM ALLOW ABLE EXP OSED VENT PIPE LENGTH - - FT (M) WITH AND WITHOUT INSULA TION IN WINTER DESIGN TEMPERA TURE AMBIENT* FURNACE SIZE WINTER DESIGN TEMPERA TURE ° F 〈° C) MAX PIPE DIAMETER IN (mm) WITHOUT INSULA TION FT (M ) WITH 3/8–IN. OR THICKER INSULA TION† FT (M ) 040 20 ( - - - 7) 1.
19 ELECTRICAL DA T A UNIT SIZE 036040 036060 036080 048080 060100 060120 U N I T V O L T S --- H E R T Z --- P H A S E 1 1 5 --- 6 0 --- 1 1 1 5 --- 6 0 --- 1 1 1 5 --- 6 0 --- 1 1 1 5 --- 6 0 --- 1 1 1 5 --- 6 0 --- 1 1 1 5 --- 6 0 --- 1 MAXIMUM UNIT AMPS 8 9.
20 TYPICAL INST ALLA TIONS COMBUSTION AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) A/C COIL OUTDOOR UNIT VENT PIPE HUMIDIFIER GAS-FIRED WATER HEATER ELECTRONIC AIR CLEANER AIRFLOW FRONT OF FURNACE COMBUS.
21 TYPICAL INST ALLA TIONS (CONTINUED) COMBUSTION–AIR PIPE ELECTRONIC AIR CLEANER FURNACE CONDENSATE DRAIN REFRIGERATION PIPING AIR CONDITIONING COIL AIRFLOW VENT PIPE FRONT OF FURNACE DIRECT VENT/2.
22 GUIDE SPECI FICA TIONS Plus 90x Single - - Stage/Deluxe Gas Furnace 353AA V GENERAL System Description Furnish a _________________ (4 - - way multipoise) fixed capacity gas- - fired condensing furn.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bryant 353AAV è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bryant 353AAV - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bryant 353AAV imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bryant 353AAV ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bryant 353AAV, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bryant 353AAV.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bryant 353AAV. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bryant 353AAV insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.