NOTE: Read the entire instruction manual before performing any service or maintenance. This symbol → indicates a change since the last issue. These procedures are for size 60,000 through 120,000 Btuh units. Index Page SAFETY CONSIDERATIONS .........
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS PROCEDURE CAUTION: Electrostatic discharge can affect electronic components. Take precautions during furnace installation and servicing to protect the furnace electronic control and motor. Precautions will prevent electrostatic discharges from personnel and hand tools which are held during the procedure.
a. Turn off electrical supply before removing blower and control access doors. b. Release filter retainer from clip at front of furnace casing. (See Fig. 4.) For side return, clips may be used on either or both sides of the furnace. c. Slide filter out.
a. Draft safeguard switch. b. Inducer motor. c. Pressure switch(es). d. Limit overtemperature switch(es). e. Gas valve. f. Hot surface ignitor. g. Flame-sensing electrode. h. Wiring connectors leading to control. 4. Remove 2 screws that secure relief box.
g. Flame-sensing electrode. h. Wiring connectors leading to control. 12. Reconnect vent pipe to relief box. 13. Replace blower door only. 14. Turn power and gas to ON. 15. Set thermostat and check furnace for proper operation. 16. Verify blower airflow and that airflow rate changes between heating and cooling.
→ Fig. 8—Heating and Cooling Application Wiring Diagram for 2-Stage Thermostats and/or 2-Speed Condensing Units A97589 115-V FIELD- SUPPLIED FUSED DISCONNECT JUNCTION BOX CONTROL BO.
→ Fig. 9—Unit Wiring Diagram A97587 RED LS FRS2 RED RED FRS1 (WHEN USED) ALS2 DSS ORN LGPS YEL NOTE 9 LPS NOTE 9 (WHEN USED) RED YEL ORN (WHEN USED) NOTE 7 ALS1 ORN SWITCH 12 HEAT SET-UP SWITCH NORM HI HT LO HT * ON OFF OFF ON BLOWER- OFF DELAY (SEC.
Fig. 10—Service Label A94169 SERVICE EACH OF THE FOLLOWING STATUS CODES IS A TWO-DIGIT NUMBE R WITH THE FIRST DIGIT DETERMINE D BY THE NUMBER OF SHORT FLASHES AND THE SECOND DIGIT BY THE NUMBER OF LONG FLASHES.
A96062 If inducer and burners continue to operate, check for 24v at the gas valve. If 24v are present, verify that the thermostat is open across R and W. If no voltage is present, turn the gas valve control knob to the OFF position. Replace gas valve.
—10—.
—11—.
A94328 SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: • Unit Familiarization.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bryant 333BAV è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bryant 333BAV - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bryant 333BAV imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bryant 333BAV ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bryant 333BAV, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bryant 333BAV.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bryant 333BAV. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bryant 333BAV insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.