Manuale d’uso / di manutenzione del prodotto 116B del fabbricante Bryant
Vai alla pagina of 22
1 16B Legacy t Line 16 Air C onditioner with Puron r Refrigeran t 1 - - 1/2 to 5 Nominal T ons Pr oduct Data the environmentally sound refrigerant Brya nt ’ s Air Condit i oner s wi t h Puron r re f r ige r a nt pr ovi de a collectio n o f features un match ed b y any oth er family of equ ip men t.
2 MODEL NUMBER NOMENCLA TURE 1 2 34 5 6 7 8 9 1 0 1 11 2 1 4 N N N A A/N N N N N A/N A/N N A 1 1 6B N A 0 3 60 0 0 0 Prod- uct Fam il y Tier SEER Major Serie s Vo l t a g e Gr ille Va r i a t i o n s .
3 REFRIGERANT PIP ING LENGTH LIMI T A TIONS Liquid Line Sizing and Maximum T otal Equival e nt Le ngths { for Coo ling O n ly Sy stems with P uron r Refrig era nt : The ma xim um all owa bl e le ngt h.
4 REFRIGERANT CHARGE ADJUSTMENTS Liquid Line S ize Puron Charge oz /ft 3/8 0.60 (F actory charg e for lineset = 9 oz) 5/16 0.40 1/4 0.27 Unit s a re fac t or y cha r ged f or 15 f t ( 4.6 m) of 3/8” liqui d li ne . The fa c t ory c ha r ge for 3/8” li ne se t 9 oz.
5 ACCESSO R Y THERMOS T A TS PA R T N U M B E R PRO GR AM GAS ELECTRIC HEA T COOL T 2 --- P A C 0 1 5 --- 2 D a y √ √ 1 1 T 2 --- N A C 0 1 NP √ √ 1 1 T2SNA C0 1 NP √ √ 1 1 THER MOS T AT A.
6 ACCESSO R Y USAGE GUIDELI NE ACCESSORY RE QUIRE D FOR LOW - - - AMBI - ENT COOLING APPLIC ATIONS (Below 55 ° F/12. 8 _ C) RE QUIRE D FOR LONG LINE APPLICATIONS* (Ov er 80 ft ./ 24. 38 m) REQUI RED FOR SEA COA ST APPLICATIONS ( W i t h i n2m i l e s / 3 .
7 Ac ce ss or y De sc r iptio n and Us age (List ed A lphabe tic ally ) ( Co ntinue d) 10. Sound Hood W r apa r ound s ound re duc i ng cove r for the c ompr es s or . Re duc e s the sound le ve l by a bout 2 dBA. Us age G uide l ine : Sugges t e d whe n unit is ins t a ll e d cl os e r t ha n 15 ft ( 4.
8 ELECTRICAL DA T A UNIT S IZE V/PH OPER VOL TS* COMP R FA N MCA MIN WIR E SIZE { 60 ° C MIN WIR E SIZE { 75 ° C MAX LENG TH ft. (m) } 60 ° C MAX LENG TH ft. (m) } 75 ° C MAX FUSE ** or CKT B RK AMPS MAX MIN LRA RLA FLA 018 - - - B 208/230/1 - - - 60 253 197 48.
9 DIMENSIONS - - ENGLISH B 3" K 5/16" L C 3 1/2" 1 7/8" N P M E F G A 208-230-1-60 230-1-60 208/230-3-60 460-3-60 UNIT SERIES ELECTRICAL CHARACTERISTICS AB C D EF G K L M NP OPERAT.
10 DIMENSIONS - - SI B C 88.9 47.6 P A 76.2 K 8.0 L N M E F G 208-230-1-60 230-1-60 208/230-3-60 460-3-60 UNIT SERIES ELECTRICAL CHARACTERISTICS AB C D EF G K L M N P OPERATING WEIGHT (Kgs) SHIPPING WEIGHT (Kgs) SHIPPING DIMENSIONS (L x W x H) 116BNA018 A X O O O 587.
11 CLEARANCES Clearances (various examples) W all 6” (152.4) 24” (609.6) Service W all W all W all 12” (304.8) 12” (304.8) 18” (457.2) 24” (609.6) Service 6” (152.4) 12” (304.8) 24” (609.6) Service 24” (609.6) Service 24” (609.6) Service Note: Numbers in ( ) = mm 18” (457.
12 TESTED AHRI COMBINA TION RA TINGS* NOTE: Ratings contained in th is documen t are subject to change at any time. For AHRI ratings certificates, please r efer to the AHRI dir ectory www .ahridirectory .org Additional rati ngs and system combinations can be accessed via the Bryant database at: http://cacta xcredits.
13 DET AILED COOLING CAP ACITIES # EVAPORA TOR AIR CO ND ENS ER ENT ERI N G AI R TEM PER ATURES ° F (° C ) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.
14 DET AILED COOLING CAP ACITIES # (CONT .) EVAPORA TOR AIR CO ND ENS ER ENT ERI N G AI R TEM PER ATURES ° F (° C ) 75 (23.9) 85 (29.4) 95 (35) 105 (40.
15 DET AILED COOLING CAP ACITIES # (CONT .) EVAPORA TOR AIR CO ND ENS ER ENT ERI N G AI R TEM PER ATURES ° F (° C ) 75 (23.9) 85 (29.4) 95 (35) 105 (40.
16 DET AILED COOLING CAP ACITIES # (CONT .) EVAPORA TOR AIR CO ND ENS ER ENT ERI N G AI R TEM PER ATURES ° F (° C ) 75 (23.9) 85 (29.4) 95 (35) 105 (40.
17 DET AILED COOLING CAP ACITIES # (CONT .) EVAPORA TOR AIR CO ND ENS ER ENT ERI N G AI R TEM PER ATURES ° F (° C ) 75 (23.9) 85 (29.4) 95 (35) 105 (40.
18 CONDENSER ONL Y RA TI NGS SST °F ( °C ) CONDENS ER ENTERING AIR TEMPERAT URES ° F (° C) 55 (12.78) 65 (18.33) 75 ( 23.89) 85 ( 29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51. 67) 116BNA018 ****B 30 ( - - - 1. 11) TCG 15.70 14.90 14.10 13.20 12.
19 CONDENSER ONL Y RA TI NGS CONTINUED SST °F ( °C ) CONDENS ER ENTERING AIR TEMPERAT URES ° F (° C) 55 (12.78) 65 (18.33) 75 ( 23.89) 85 ( 29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51. 67) 116BNA036 ****A 30 ( - - - 1. 11) TCG 31.50 29.90 28.
20 CONDENSER ONL Y RA TI NGS CONTINUED SST °F ( °C ) CONDENS ER ENTERING AIR TEMPERAT URES ° F (° C) 55 (12.78) 65 (18.33) 75 ( 23.89) 85 ( 29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51. 67) 116BNA049 ****A 30 ( - - - 1. 11) TCG 45.00 42.40 39.
21 GUI D E SPEC I FIC A TI ON S GENERAL Sy stem D escriptio n Outdoor- - mount ed, a i r- - coole d, spl i t- - sys t e m ai r cond it i one r unit sui t a ble f or gr ound or rooft op ins t al l a ti on. Uni t cons i s ts of a her me tic com pre s s or , a n ai r- - cool e d coi l , pr opel l e r- - type conde ns e r fa n, a nd a cont rol box.
22 SYSTE M DE SIGN SU MMA R Y 1. Int e nde d for outdoor i ns ta l l at i on wi th f r e e a i r inl e t a nd out l et . Out door f a n e xte r na l s t a ti c pr es s ur e a va i la bl e is les s t han 0.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bryant 116B è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bryant 116B - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bryant 116B imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bryant 116B ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bryant 116B, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bryant 116B.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bryant 116B. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bryant 116B insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.