MODEL CO5120PDB—USER’S MANUAL AC POWERED CARBON MONOXIDE ALARM WITH BA TTER Y BACK-UP AND DIGIT AL DISPLA Y M06-1060-000 08/01 PLEASE READ CAREFULL Y AND SA VE: This unit was shipped with a user’ s manual that contains important information about its operation.
CHAPTER 1: INTRODUCTION BASIC SAFETY INFORMA TION Dangers, W arnings, and Cautions alert you to impor- tant operating instructions or to potentially hazardous situations. Pay special attention to these items. THIS IS NOT A SMOKE ALARM! This CO Alarm is designed to detect carbon monoxide from ANY source of combustion.
1 Basic safety information (continued)... NEVER ignore any alarm. Refer to Chapter 3 for more information on how to respond to an alarm. Failure to respond can r esult in injury or death.
2 BASIC POWER CONDITIONS Alarm operating on AC power Alarm operating on emergency battery back-up Low / missing battery warn- ing WHA T YOU SEE AND HEAR DURING INST ALLA TION Under normal conditions (.
3 If battery becomes low or is missing *Note: If the battery becomes very weak, you will hear extra “ chirps. ” Replace the battery immediately! Disconnect AC power before changing battery .
4 If you silence the alarm Horn Silent for about 4 minutes* Display Shows CO levels detected in ppm POWER/ Flashes once ALARM Light per second *Note: After 4 minutes, if CO levels drop below alarm levels, the unit will remain silent and return to normal operation.
5 Gas Detection at T ypical T emperature and Humidity Ranges: The CO Alarm is not formulated to detect CO levels below 30 ppm typically . UL tested for false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon Dioxide (5000 ppm).
6 CHAPTER 2: INST ALLA TION WHERE TO INST ALL CO ALARMS The National Fire Protection Association (NFP A) rec- ommends that a CO Alarm should be centrally locat- ed outside of each separate sleeping area in the immediate vicinity of the bedrooms.
7 WHERE NOT TO INST ALL THIS ALARM DO NOT locate this CO Alarm: • In garages, kitchens, furnace rooms, crawl spaces and unfinished attics. Avoid extremely dusty , dirty or greasy areas. • The CO Alarm should be at least 5 feet (2 meters), preferably 20 feet (6 meters) from sour ces of combustion particles such as stoves, furnaces, and vehicles.
8 THE BA TTER Y COMP ARTMENT LOCK : TO LOCK THE BA TTERY COMP ARTMENT Do not lock the battery compartment until you have activated the battery and tested the battery back-up. 1. Activate the battery back- up by removing the “ Pull to Activate Battery Back- Up ” tab.
9 T o Lock the Battery Compartment (continued)... 3. Push the locking pin through the black dot on the label on the back of the CO Alarm. TO UNLOCK THE BA TTERY COMP ARTMENT : Once the CO Alarm is installed, you must disconnect it from the AC power before unlocking the battery compartment.
10 THE MOUNTING BRACKET LOCK T ools you will need: • Needle-nose pliers • Standard/Flathead scr ewdriver TO ACTIV A TE THE BRACKET LOCK: 1. Using needle-nose pliers, detach one locking pin from the mounting bracket. 2. Insert the locking pin into the lock located on the pivoting hinge of the battery door .
11 T o Deactivate the Bracket Lock (continued)... 2. Pry the CO Alarm away from the bracket by turn- ing both the screwdriver and the CO Alarm counterclockwise (left) at the same time. TO PERMANENTL Y REMOVE THE BRACKET LOCK: Insert the flathead screwdriver between the locking pin and the lock, and pry the pin out of the lock.
12 THE P ARTS OF THIS CO ALARM 1 Mounting Bracket 2 Mounting Slot and Screw 3 Locking Pins (break out of bracket) 4 Hot (Black) AC Wire 5 Neutral (White) AC Wire 6 Interconnect Wire (Violet) 7 Lever t.
13 ELECTRICAL SHOCK HAZARD. Do not restore power until the CO Alarm is completely installed. Restoring power before installation is complete may result in serious electrical shock, injury or death. 7. Make sure the unit is receiving AC power . Under normal operation, the red indicator light will shine continuously .
14 Interconnected units can provide earlier warning of a CO problem than stand-alone units, especially if the problem starts in a remote ar ea of the dwelling. If any unit in the series senses CO, all units will alarm. T o determine which CO Alarm initiated an alarm, refer to the table.
15 MUL TIPLE-ST A TION INST ALLA TION ELECTRICAL SHOCK HAZARD. T urn off power to the area where you will install this unit at the cir cuit breaker or fuse box before beginning installation. Failure to turn off the power before installation may result in serious electrical shock, injury or death.
16 8. If the red power indicator light does not light, TURN OFF POWER TO THE JUNCTION BOX and recheck all connections. If all connections are correct and the red power indicator still does not light when you restore the power , the unit should be replaced immediately .
17 In a series of interconnected Alarms, you must test each Alarm separately by pressing and holding the test button. Make sure all units alarm when each one is tested. If any unit in the series does not alarm during testing, TURN OFF POWER and recheck connections.
18 Display Shows... It Means... 30 Developing CO problem. Display will (or higher) only show levels of carbon monoxide 30 ppm or higher . 70 The unit is calibrated to sound an alarm (or higher) before 240 minutes have passed when exposed to this level.
19 The Latching Alarm Indicator is activated after a CO Alarm is exposed to alarm levels of carbon monoxide. After CO levels drop below alarm levels, the red LED will begin to flash once every 5 seconds. It will continue to flash or “ latch ” until you clear it by pressing the test button.
20 CHAPTER 4: TESTING AND MAINTENANCE WEEKL Y TESTING Push and hold the T est/Silence button until a loud alarm sounds — 4 beeps, pause, 4 beeps. This sequence should last for 10 seconds. If the Alarm ever fails to test properly , replace it immediately .
21 CHAPTER 5: WHA T YOU NEED TO KNOW ABOUT CO WHA T IS CO? CO is an invisible, odorless, tasteless gas produced when fossil fuels do not burn completely , or are exposed to heat (usually fire). Electrical appliances typically do not produce CO. These fuels include: W ood, coal, charcoal, oil, natural gas, gasoline, kerosene, and propane.
22 POTENTIAL SOURCES OF CO IN THE HOME Fuel-burning appliances like: portable heater , gas or wood burning fireplace, gas kitchen range or cooktop, gas clothes dryer . Damaged or insufficient venting: corr oded or dis- connected water heater vent pipe, leaking chimney pipe or flue, or cracked heat exchanger , blocked or clogged chimney opening.
23 HOW CAN I PROTECT MY F AMIL Y? A CO Alarm is an excellent means of protection. It monitors the air and sounds a loud alarm before carbon monoxide levels become threatening for average, healthy adults. A CO Alarm is not a substitute for proper maintenance of home appliances.
24 CHAPTER 6: UNDERWRITERS LABORA TORIES INC. UL2034 WHA T LEVELS OF CO CAUSE AN ALARM? Underwriters Laboratories Inc. UL2034 defines 3 specific alarm points by which all residential CO Alarms must alarm. They are measured in parts per million (ppm) of CO over time (in minutes).
25 Once a minute, the alarm sounds 3 quick “ chirps ” , and the red light flashes quickly three times and display reads “ Err ” . Based on its Self T est diagnostics, the unit has detected a malfunction. The unit needs to be replaced. Units under warranty should be returned to manufacturer for replacement.
26 CHAPTER 8: GENERAL LIMIT A TIONS OF CO ALARMS This CO Alarm is intended for residential use. It is not intended for use in industrial applications wher e Occupational Safety and Health Administration (OSHA) requir ements for carbon monoxide detectors must be met.
27.
Coverage: BRK Brands, Inc. ("BRK") the maker of BRK Electronics ® brand products, warrants that for a period of 5 years from the date of purchase, this product will be free fr om defects in material and workmanship.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il BRK electronic CO5120PDB è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del BRK electronic CO5120PDB - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso BRK electronic CO5120PDB imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul BRK electronic CO5120PDB ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il BRK electronic CO5120PDB, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del BRK electronic CO5120PDB.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il BRK electronic CO5120PDB. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo BRK electronic CO5120PDB insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.