Manuale d’uso / di manutenzione del prodotto VG5-7220-EPC4 del fabbricante Bosch
Vai alla pagina of 154
AUTODOME IP 7000 HD VG5-7130, VG5-7230 en Operation Manual.
.
Table of contents 1 Safety EN 6 1.1 About this Manual 6 1.2 Legal Information 6 1.3 Safety Precautions 6 1.4 Important Safety Instructions 6 1.5 Important Notices 8 1.6 Connection in Applications 12 1.7 Customer Support and Service 12 2 Unpacking 13 2.
11.2 Power Cable and Wire Distances Guides 72 11.3 Ethernet Connections 73 11.4 Fiber Optic Ethernet Media Converter (Optional) 74 11.5 Alarms and Relay Connections 75 11.6 Audio Connections (Optional) 78 12 Configuration 81 12.1 System Requirements 81 12.
14.32 VCA 117 14.33 Virtual Masks 121 14.34 Audio Alarm 121 14.35 Alarm E-Mail 122 14.36 Alarm Task Editor 123 14.37 Alarm Rules 123 14.38 Advanced Mode: Interfaces 124 14.39 Alarm Inputs 124 14.40 Alarm Outputs 124 14.41 Advanced Mode: Network 124 14.
Safety EN About this Manual This manual has been compiled with great care and the information it contains has been thoroughly verified. The text was complete and correct at the time of printing. Because of the ongoing development of products, the content of the manual may change without notice.
3. Ventilation - Any openings in the unit enclosure are provided for ventilation to prevent overheating and ensure reliable operation. Do not block or cover these openings. Do not place the unit in an enclosure unless proper ventilation is provided, or the manufacturer's instructions have been adhered to.
an object has fallen into the unit; unit has been dropped or the unit cabinet is damaged; unit exhibits a distinct change in performance; unit does not operate normally when the user correctly follows the operating instructions.
Section 810 of the National Electrical Code, ANSI/NFPA No.70 , provides information regarding proper grounding of the mount and supporting structure, grounding of the coax to a discharge unit, size of grounding conductors, location of discharge unit, connection to grounding electrodes, and requirements for the grounding electrode.
SELV - All the input/output ports are Safety Extra Low Voltage (SELV) circuits. SELV circuits should only be connected to other SELV circuits. Because the ISDN circuits are treated like telephone-network voltage, avoid connecting the SELV circuit to the Telephone Network Voltage (TNV) circuits.
instructions, générer des interférences nuisibles aux communications radio. L’utilisation de ce produit dans une zone résidentielle peut provoquer des interférences nuisibles. Le cas échéant, l’utilisateur devra remédier à ces interférences à ses propres frais.
Connection in Applications 24 VAC power source: This unit is intended to operate with a limited power source. The unit is intended to operate at 24 VAC (if High PoE is not available). User supplied wiring must be in compliance with electrical codes (Class 2 power levels).
Unpacking This equipment should be unpacked and handled with care. If an item appears to have been damaged in shipment, notify the shipper immediately. Verify that all the parts listed in the Parts List below are included. If any items are missing, notify your Bosch Security Systems Sales or Customer Service Representative.
Mounting Options Part Numbers – Power Box with 120 VAC transformer or with 230 VAC transformer VG4-A-PA1 VG4-A-PA2 Power Supply Box and cover with 120 VAC transformer or with 230 VAC transformer VG4.
Tools Required Quantity Item For Mount Type Supplied by Bosch? 1 Allen wrench, 5 mm Pendant Arm to: – Wall Mount – Corner Mount – Mast (pole) Mount – Roof parapet Mount – Pipe Mount Yes 1 Screwdriver, straight- blade, 2.
1 Right angle NPS conduit connector, 3/4 in. (20- mm) Mast (pole) mount with VGA-PEND-WPLATE No 1 Screwdriver, medium straight blade – Roof parapet Mount – Pipe Mount No 1 Screwdriver, No.
Additional Products Required The following table lists additional products, sold separately by Bosch or other manufacturers, necessary to install AUTODOME cameras. Quantity Product Part Number Size 1 SD card (user-supplied) --- Water tight metal conduit (user-supplied) 20 mm (0.
System overview The AUTODOME 7000 Series camera includes the following functionality: Function Description Video Encoding The camera uses the H.264 compression standards and ensures that the data rate remains low even with high image quality and can also be adapted to local conditions within wide limits.
Pre-installation Checklist 1. Determine the location and distance for the power supply box based on its voltage and current consumption. You may choose to route the main power supply through an intermediate power supply box (VG4-PSU1 or VG4-PSU2) before connecting the power to the pendant arm power supply box (VG4-PA0).
Stabilization Surveillance cameras are susceptible to vibrations caused by wind or vibrations emanating from the medium to which the camera is attached.
Installing the Optional SD Card The camera can accept a customer-supplied SDHC or SDXC memory card (hereafter referred to as “SD card”) for local storage. (The camera will not accept MicroSD cards.) Using an SD card is optional. Ideally, you should install the SD card before mounting the camera.
Mount Power Supply Box (Wall, Mast (Pole), and Corner Mounts) Before mounting the Power Supply Box, decide if you should wire the box through the holes in the bottom or back of the box. If wiring the box through the back, move the two (2) seal plugs to the bottom through the holes before mounting.
! Warning! For units intended to be installed outdoors: All wiring (power and I/O cabling) connecting to the unit must be routed separately inside different permanently earthed metal conduits (not supplied). AUTODOME IP 7000 HD Mount Power Supply Box (Wall, Mast (Pole), and Corner Mounts) | en 23 Bosch Security Systems Operation Manual 2014.
Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts Description This chapter details how to install an AUTODOME to a Wall, Corner, or Mast (pole) mount.
Connecting Alarm Inputs and Outputs 4 To connect alarm inputs and outputs, attach the supplied 6-pin Alarms In and the 4-pin Alarms Out connector plugs with flying lead wires to the appropriate incoming alarm wires. Alarm Out 4 is a relay. 1 1 2 3 4 5 6 2 3 4 N.
Power Supply Box Connections The following figure is a detailed illustration of the Pendant Arm Power Supply Box, which includes the fuse specifications.
Cables/wires that are routed through number 2 in the illustration above come from the Nexus cable bundle that is in the pendant Arm. Fuse Specifications Volts XF101 Mains XF102 Camera XF103 Heater 24 V T 5.0 A T 2.0 A T 3.15 A 115 V T 1.6 A T 2.0 A T 3.
! Warning! For units intended to be installed outdoors: All wiring (power and I/O cabling) connecting to the unit must be routed separately inside different permanently earthed metal conduits (not supplied).
To properly wire the incoming high voltage and the outgoing low voltage lines, refer to this table: No. Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Ground Grounding Screw P101 120/230 VAC Power In Line NC Neutral P107 24 VAC Power Out Earth Ground Heater (24 VAC) Heater (24 VAC) Table 7.
! Warning! Ensure that you connect the outgoing power supply wires to the P107 heater connectors (HN and HL). The heater power (XF103) fuse can handle a higher amperage (3.
Attach Pendant Arm to Power Supply Box The bottom hinge pin of the Pendant Arm is provided with a Hinge Pin Stop to hold the hinge open while attaching the arm to the Power Supply Box. 1. Compress the bottom hinge pin by pushing the pin lever downward and rotating it behind the Hinge Pin Stop.
Make Connections in the Power Supply Box 1 2 3 Figure 7.8: Pendant Arm connections to Power Supply Box 1. Attach the earth ground wire (item 1 in the illustration above) to the grounding screw on the left side of the power box. 2. Connect the 6-pin Control In/Out Plug, installed previously, to its mating connector P106 in the power box.
Installing the VGA-PEND-WPLATE This section provides instructions to install a wall, corner, or mast mount with the VGA-PEND- WPLATE Mounting Plate instead of a Power Supply Box.
3. Ensure that the mounting plate is secure. Attach the Pendant Arm to the Mounting Plate The bottom hinge pin of the Pendant Arm is provided with a Hinge Pin Stop to hold the hinge open while attaching the arm to the Mounting Plate. 1. Compress the bottom hinge pin by pushing the pin lever downward and rotating it behind the Hinge Pin Stop.
4. Once you have the hinges aligned, release the top hinge pin to engage its mating hinge on the Mounting Plate. Then release the bottom hinge pin from the Hinge Pin Stop to lock the Pendant Arm to the Mounting Plate.
Figure 7.11: Mounting Plate - Inside Detail Ref. Description 1 Grounding lug with two spade terminals 2 Earth ground lug with crimp ring terminal 3 Wire input conduit holes 4. Connect the incoming 24 VAC power wires to the 5-pin, 24 VAC Power In mating connector (supplied with the Mounting Plate kit) for the camera and for the Heater.
14. Attach the 6-pin serial communication mating connector to the Serial Communications cable (cable 8). 15. Connect the Earth ground wire, if available, to the crimp ring terminal inside the Mounting Plate. Note : The Earth ground is not provided with the VGA-PEND-WPLATE kit; it is a ground connection made at the installed location.
a b Figure 7.12: Attach Pendant to Arm 1 Tilt up. 2 Hook and drop. 2a Recessed Hinge Pin 2b Dome Connector 3 Rotate down to engage dome connector. 4 Tighten the two (2) mounting screws to a minimum torque of 10-12 N-m (90-105 in.
! Caution! You must tighten the two mounting screws to a minimum torque of 10-12 N-m (90‑105 in.-lbs) to ensure a proper seal between the arm and the housing. AUTODOME IP 7000 HD Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en 39 Bosch Security Systems Operation Manual 2014.
Installing the Roof Parapet and Pipe Mounts Description This chapter details how to install an AUTODOME camera to a Roof Parapet or to a Pipe mount. Any differences to the installation between these two mounting systems are noted. The VGA-ROOF-MOUNT is a stationary mount intended for rooftop parapet vertical walls.
GND TXD RXD C+ C- GND TXD RXD C+ C- P101 P106 P105 P107 XF102 XF103 XF101 5 4 3 2 1 J103 J103 J103 J102 J101 (LED) HTR DOME (FUSE) (FUSE) (FUSE) (FUSE) LINE NC NEUT Figure 8.1: VG4-A-PSU1 or VG4-A-PSU2 Power Supply Box 1 120 VAC/230 VAC Power In 6 Control Wire Used for Audio input and output in AUTODOME 7000 Series.
GND TXD RXD C+ C- GND TXD RXD C+ C- P101 P106 P105 P107 XF102 XF103 XF101 5 4 3 2 1 J103 J103 J103 J102 J101 (LED) HTR DOME (FUSE) (FUSE) (FUSE) (FUSE) BNC J102 P107 P101 P102 P103 P104 P106 J101 AGND A7 A6 A5 A4 A3 AGND OUT 3 OUT 2 OUT 1 P105 LINE NC NEUT Figure 8.
1. Cut and trim the high voltage 115/230 VAC power and ground wires with sufficient slack to reach their connector terminal in the box, but not so long as to be pinched by or to obstruct closing the Cover Door. 2. Attach the supplied 3-pin Power Plug to the incoming high voltage power wires in the box.
GND TXD RXD C+ C- P101 P106 XF102 XF103 XF101 5 4 3 2 1 J103 J103 J103 J102 J101 (LED) HTR DOME 24V NC 24V (FUSE) (FUSE) (FUSE) (FUSE) Figure 8.
Power Supply Box Connections The following figure is a detailed illustration of the Roof or Pipe Mount Power Supply Box, which includes the fuse specifications.
No. Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Ground Grounding Screw P101 115/230 VAC or 24 VAC Power In Line NC Neutral P107 24 VAC Power to Dome Plug Dome 24 VAC Dome 24 VAC Earth Ground Heater (24 VAC) Heater (24 VAC) Table 8.1: Power Box Connections Attach Cover Door to Power Supply Box 1.
4. When the hinges are aligned, release the top hinge pin to engage its mating hinge on the power box. Then release the bottom hinge pin from the Hinge Pin Stop to complete attaching the Cover Door to the Power Supply Box.
Figure 8.7: Parapet Wall Mount Bracket and Roof Mount Plate 1 Pipearm 4 Apply sealant around each fastener hole 2 Parapet Wall Bracket 5 Roof Mount Plate 3 3/8-16 SS Hex Head Bolt (supplied) 6 Use a minimum of six (6) fasteners (not supplied). Eight (8) fastener holes shown.
Figure 8.8: VGA-ROOF-MOUNT 1 End Cap with O-ring 2 Parapet Pipe Arm 3 1/4-20 SS Cap Screw 4 Down Pipe 5 10-24 SS Pan Head Screw 7. Fold the video, control, and power wires back at the front end of the arm and route them down and out through the Down Pipe.
Figure 8.9: Attach Dome Cap 1 Thread Sealant or tape 2 Dome Cap 11. Run a bead of RTV Silicon sealant around the down pipe/Dome Cap interface to seal any gaps between the down pipe and the Dome Cap. 12. Proceed to Wire the Pipe Interface Board, page 52 .
5 i n. 12.7 cm min. Figure 8.10: Pipe Mount 1 Gasket 2 Flange 3 Cap 1. Before installing the Top-Mounting Flange, ensure there is an adequate opening in the ceiling or mounting structure for the wires to pass through.
Wire the Pipe Interface Board This section provides instructions for connecting wires and cables to the Pipe Interface Board, as illustrated below. Refer to the Connection, page 72 chapter for cable and wiring recommendations and specifications.
Ref. Description Connecto r Wire Gauge Pin Description 1 Pipe Interface Module 2 Video Coax In J102 3 6-pin Connector Alarms In (3-7) P103 4 4-pin Connector Alarms Out (1-3) P102 5 100 Ω Resistor Note: When using the audio input in an AUTODOME 7000 Series camera, remove this resistor.
Ref. Description Connecto r Wire Gauge Pin Description 1 Dome 24 VAC 10 Heater Power P107 AWG 18-14 2 Heater 24 VAC 1 Heater 24 VAC 11 RJ45 Ethernet J101 12 To camera The Pipe Interface Board contains all of the connectors for control, data, image, and power wires.
1 4-pin Alarm Connector (P102) 2 6-pin Alarm In Connector (P103) 3 7-pin Relay Connector (P104) Pin Description Pin Description Pin Description 1 Alarm Out 1 1 Alarm in 3 1 Alarm Out 4 Normally Open 2.
Figure 8.13: Pipe Interface Board to Dome Cap Assembly 1 Interface Board 2 Retaining Screws (3) 3 Pendant Mounting Screws (2) Attach Pendant to Pipe and Tighten 1. Before attaching the Pendant, visually inspect the Pendant dome and the Interface Board connectors for any blocked pin holes and bent pins.
a b c Figure 8.14: Pendant to Roof / Pipe Mount Attachment 1 Tilt Dome 2 Hook and drop 2a Dome Cap 2b Recessed Hinge Pin 2c Dome Connector 3 Rotate down to engage dome connector 4 Tighten the two (2) mounting screws to a minimum torque of 10-12 N-m (90-105 in.
4. Rotate the dome housing down to a vertical position and gently push upward to engage the connector on top of the dome housing. ! Caution! If you feel any resistance when rotating the dome housing or when engaging the connector, stop immediately and start over.
Installing the In-Ceiling Mount Description This chapter details how to install the camera in an In-Ceiling Mount. The In-Ceiling AUTODOME camera is suitable for use in environmental air spaces.
Figure 9.2: Cut Hole in Ceiling Tile 2. Tighten the four (4) securing screws to the Bracket Assembly. Figure 9.3: Tighten Bracket Securing Screw 3. Secure the Bracket Assembly to an overhead securing point with a safety wire. Figure 9.4: Secure Bracket Assembly 60 en | Installing the In-Ceiling Mount AUTODOME IP 7000 HD 2014.
Wire the Interface Box The Interface Box can be wired through the top or side. Use the supplied rubber plug to seal the hole which will not be used to route wires. Figure 9.5: Interface Box Connections After routing all video, control, power, and alarm wires: 1.
1 1 2 3 4 5 6 2 3 4 N.O . COM N.C . A1 GND A2 1 PIN PIN P102 P103 P104 WHITE ORA NGE BROWN GRE EN WHI TE ORANGE BRO WN GREEN YEL LOW BLUE 2 3 4 5 6 7 Figure 9.
P10 5 P10 4 P10 2 P10 3 J101 J102 24V AC 24V AC P10 1 SIG GND TXD (-) RXD (+) C + C - NC NO COM AGN D A2 A1 J103 A3 A4 A5 A6 A7 AGN D AGN D OUT3 OUT2 OUT1 Figure 9.7: In-ceiling Interface Box 1 Fiber Optics 5 Coax Video [Not applicable for AUTODOME 7000 Series cameras.
Notice! Pins for P105 1, 2, 4, and 5 are used for audio input and output for AUTODOME 7000 Series cameras; however, their labels are still those of previous versions of analog AUTODOME cameras.
1 2 3 4 5 Figure 9.8: In-ceiling (IP54 Rating) Installation Diagram 1 White Trim Ring (factory-installed on dome bubble) 5 Inner Ring 2 Black Trim Ring (supplied in the shipping box of the camera) 6 Ceiling (IP54 housing) Gasket 3 Bubble 7 In-ceiling housing 4 Trim Ring Gasket 1.
Figure 9.9: Attach Housing to Interface Box 1. Insert the In-ceiling housing through the hole in the ceiling to verify that the edge of the hole support the unit. Then remove the housing from the hole. 2. Align the ball studs of the In-Ceiling Housing to the Stud Retainers on Interface Box and attach.
! Caution! The In-ceiling dome is provided with tether points on each side of the housing. To prevent injury, attach a safety wire from a secure anchor point above the ceiling to a tether point on the dome housing. See below for an illustration. Secure Housing to Ceiling The In-ceiling Housing is secured to the ceiling by two (2) screw clamps.
mm inches 40 mm 1.57 in. MA XIMUM CEILING 6.5 mm 0.26 in. MINIMUM CEILING Figure 9.11: Secure camera to ceiling 1 Tether Point 4 Ceiling Clamp 2 Ceiling Clamp 5 Rotate Clockwise to Engage Clamp 3 Tether Point ! Caution! Over-torquing the Ceiling Clamps can damage the clamp or ceiling.
Preparing the Bubble The inside of the housing may contain packing material to safeguard the camera during shipping. If so, you must remove the packing material before attaching the in-ceiling housing to the interface box.
Figure 10.2: Pendant Bubble Release Opening 3. Firmly rotate the bubble counterclockwise approximately 20 degrees until the bubble assembly releases from the Pendant Housing. Replace the trim ring (optional) (In-ceiling models) The dome bubble for in-ceiling models of AUTODOME 7000 comes assembled with a white trim ring.
Replace the bubble in an in-ceiling housing Figure 10.3: In-Ceiling Bubble 1. Use a non-permanent marking instrument (such as chalk or a carpenter pencil) to mark on the ceiling the screw slot in the in-ceiling housing. 2. Place the bubble over the Camera Module, and align it until it settles.
Connection Connecting the AUTODOME camera to the PC 1. Install the camera according to the instructions in the appropriate Installation section of this manual. 2. Connect an Ethernet cable from camera’s RJ45 connector to a dedicated network switch to bypass the Local Area Network (LAN).
! Caution! Compliance with EN50130-4 Alarm Standard – CCTV for Security Applications To meet the requirements of the EN50130-4 Alarm Standard, an ancillary uninterruptable power (UPS) supply is necessary.
! Caution! Ethernet CAT 5E/CAT 6 cables must be routed through earth-grounded conduit for indoor or outdoor applications. For outdoor applications, the conduit should be capable of withstanding the outdoor environment. Notice! The heater in an outdoor AUTODOME unit cannot be powered via the Power-over-Ethernet + (IEEE 802.
Ethernet Media Converter Maximum Distance 20 km (12.4 miles) Requirement Media converter receiver (CNFE2MC/IN) at controller end of system Terminal Connection Duplex LC or Single SC Alarms and Relay Connections Alarm Inputs The camera provides seven alarm inputs.
2.2K Figure 11.2: N.O.S. - Normally Open Supervised Connections 1 Dry Contact 3 Dome Connector 2 Alarm 1 or 2 only (Pin 5 or 6) 4 Ground (Pin 7) 3. From the Settings menu, select Advanced Mode > Interfaces > Alarm Inputs, select the Alarm Input # and N.
Configuring Non-supervised Alarms (inputs 3 through 7) You can configure alarms 3 through 7 as non-supervised Normally Open (N.O.) or Normally Closed (N.C.) alarms. Configuring a Normally Open Non-supervised Alarm 1. Connect the alarm to the appropriate input (3 through 7) and ground at the camera.
Alarm Outputs The camera incorporates two (2) types of alarm outputs: one dry contact relay and three (3) open collector outputs or transistor outputs. Configuring a Dry Contact Relay The dry contact relay acts like an on/off switch. It has a maximum voltage rating of 2 A @ 30 DC.
Shield Bare copper braid: 95% coverage Internal gain level adjustment is available in case the signal level is too low. Wire Specifications Wire Type Shielded Coax (recommended) Distance Typically 10 .
Notice! Separate the audio cables from the AC power lines to avoid noise. To configure audio on the camera, refer to Basic Mode: Audio, page 87 or Audio, page 109 .
Configuration System Requirements The camera requires specific software and hardware to allow a user to view live images and to configure camera settings over a TCP/IP network.
Configuring the Camera To operate the camera in your network, you must assign a valid network IP address to it. If your network has a DHCP server, the IP address of the camera defaults to the first address available. If your network does not have a DHCP server, the default IP address of the camera is 192.
4. Click the Settings link, located at the top of the LIVE page. 5. In the left pane of the window, click Advanced Mode , and then click Network . The Network menu expands. 6. Click Network Access to open the Network Access page. Figure 12.1: Network Access page 7.
8. Click Set and Reboot. The device will reset (go through the homing sequence, which usually takes 30 seconds to complete), and then the LIVE page appears, with updated video and the new IP address. Notice! Click the Help on this page? link if you need more information.
2. Click the Set and Reboot button. The camera reboots and the changed settings are activated. Configuring Audio (Optional) Enabling Audio Transmission To transmit audio via the IP connection, follow these steps: 1. Open the LIVE page, and then click the Settings tab.
Configuration via IP, Basic Mode Basic Mode: Device Access Camera name You can give the camera a name to make it easier to identify. The name makes the task of administering multiple units in larger video monitoring systems easier, for example using the Bosch Video Management Systems programs.
Some changes only take effect after the unit is rebooted. In this case, the Set button changes to Set and Reboot . 1. Make the desired changes. 2. Click the Set and Reboot button.
Basic Mode: System Overview The data on this page are for information purposes only and cannot be changed. Keep a record of this information in case technical assistance is required.
Configuration via IP, Advanced Mode Advanced Mode: General Identification Camera name The camera name makes it easier to identify the remote camera location, in the event of an alarm for example. It will be displayed in the video screen if configured to do so.
Notice! Proper password protection is only guaranteed when all higher authorization levels are also protected with a password. If a live password is assigned, for example, a service and a user password must also be set.
Daylight saving time The internal clock can switch automatically between normal and daylight saving time (DST). The unit already contains the data for DST switch-overs up to the year 2018. You can use these data or create alternative time saving data if required.
Time stamping This field sets the position of the time overlay. It can be displayed at the Top , at the Bottom or at a position of your choice that you can then specify using the Custom option. Or it can be set to Off for no overlay information. 1. Select the desired option from the list.
Enter the interval (in seconds) between insertions of the digital signature. Advanced Mode: Web Interface Appearance On this page you can adapt the appearance of the web interface and change the website language to meet your requirements.
LIVE Functions On this page you can adapt the functions on the LIVE page to your requirements. You can choose from a variety of different options for displaying information and controls. 1. Check the box for the items that are to be made available on the LIVE page.
2. If necessary, click Browse to find a suitable directory. Logging Save event log Check this option to save event messages in a text file on your local computer. You can then view, edit and print this file with any text editor or the standard Office software.
! Caution! The camera disables the Privacy Mask function if the orientation is set to Inverted. SC settings Click the Default button to restore all camera settings to their original defaults.
Encoder Profile Figure 14.1: Advanced Mode>Camera>Encoder Profile>Profile 1 [HD models only] For the video signal encoding, you can select a code algorithm and you can change the presets for the profiles. You can adapt the video data transmission to the operating environment (for example network structure, bandwidth, data load).
Notice! In the default setting, Stream 1 is transmitted for alarm connections and automatic connections. Keep this fact in mind when assigning the profile.
Target bit rate To optimize use of the bandwidth in the network, limit the data rate for the device. The target data rate should be set according to the desired picture quality for typical scenes with no excessive motion.
lower the frame refresh rate depending on the settings for the maximum data rate under network settings. A higher quantization value results in low image quality and lower network load. Typical QP values are between 18 and 30. The basic setting Auto automatically adjusts the quality to the settings for the P-frame video quality.
Options with “H.264 MP 720p50/60 Fixed” selected for Stream 1: – Copy Stream 1 – H.264 MP SD – H.264 MP 720p6/7 Fixed – H.264 MP upright (cropped) – H.264 MP D1 4:3 (cropped) Options with “H.264 MP 720p25/30 Fixed” selected for Stream 1: – H.
HD Profiles (Configuration Parameters) DSL Optimized Target bit rate: 380 kbps Maximum bit rate: 500 kbps Encoding interval: 30.00 ips 3G Optimized Target bit rate: 80 kbps Maximum bit rate: 100 kbps Encoding interval: 30.00 ips Preview Click the Preview button to open a small static preview window for each stream.
Notice! Draw the mask 10% larger than the object to ensure that the mask completely covers the object as the camera zooms in and out. Click the Zoom threshold box. Draw the mask at 50% optical zoom or less for improved masking performance. Notice! The camera disables the Privacy Mask feature if the orientation of the camera is set to Inverted.
Color hue The degree of color in the video image (HD only). Values range from -14° to 14°; the default is 8°. Gain control Adjusts the automatic gain control (AGC). Automatically sets the gain to the lowest possible value needed to maintain a good picture.
Backlight compensation Optimizes the video level for the selected area of the image. Parts outside this area may be underexposed or overexposed. Select On to optimize the video level for the central area of the image. The default setting is Off. High Sensitivity Adjusts the level of intensity or lux within the image (HD only).
Lens Settings Autofocus Continuously adjusts the lens automatically to the correct focus for the sharpest picture. – One Push (default; commonly called “Spot Focus”): activates the Auto Focus feature after the camera stops moving. Once focused, Auto Focus is inactive until the camera is moved again.
– Scene 1 : camera returns to Preset 1. – Previous Aux : camera returns to the previous activity. Inactivity period Determines the behavior of the dome when the control for dome is inactive. Select a time period from the pull-down list (3 sec. - 10 min.
3. Click the View Control link, under the image cameo, to access the directional and zoom controls. 4. Use the View Control dialog box to make the necessary camera movements. 5. Click the Stop Recording button to save all actions. North point Click the Set button to overwrite the existing North point.
Type 8 in the input box and click the Aux On button. 5. To stop the tour, type 8 and click the Aux Off button. Notice! Refer to the document “AUTODOME_OperationGuidelines_2014.pdf” for guidelines for operating your camera using Guard Tours and Preset Tours.
Line Out You can set the line output gain with the slider (from 0 (zero) to 79, with 0 as the default). Make sure that the display does not go beyond the green zone during modulation. Recording format Select a format for audio recording. Select L16 or AAC (Advanced Audio Coding) if you want better audio quality with higher sampling rates.
1. Enter the IP address of the required iSCSI destination in the iSCSI IP address field. 2. If the iSCSI destination is password protected, enter this into the Password field. 3. Click the Read button. The connection to the IP address will be established.
Deactivating Storage Media You can deactivate any storage medium from the Managed storage media list. It is then no longer used for recordings. 1. Click a storage medium in the Managed storage media list to select it. 2. Click the Remove button below the list.
Alarm input / Analysis alarm / Video loss alarm Here you can select the alarm sensor that is to trigger a recording. Virtual alarm Here you can select the virtual alarm sensors that are to trigger a recording, via RCP+ commands or alarm scripts, for example.
Holidays You can define holidays that are not in the standard weekly schedule on which recordings are to apply. This allows you to apply a schedule for Sundays to other days with dates that fall on varying weekdays. 1. Click the Holidays tab. Any days that have already been selected will be shown in the table.
Advanced Mode: Alarm Alarm Connections You can select how the camera responds to an alarm. In the event of an alarm, the unit can automatically connect to a pre-defined IP address. You can enter up to ten IP addresses to which the camera will connect in sequence in the event of an alarm, until a connection is made.
Notice! If you enter the destination IP address 0.0.0.0 for destination 10, this address will no longer be used for the tenth attempt at automatic connection in the event of an alarm.
Auto-connect Select the On option to automatically re-establish a connection to one of the previously specified IP addresses after each reboot, after a connection breakdown or after a network failure. Notice! In the default setting, Stream 2 is transmitted for automatic connections.
You can rename the profile. 1. To rename the file, click the icon to the right of the list field and enter the new profile name in the field. 2. Click the icon again. The new profile name is saved. Preset Select Off or Test. Alarm status The alarm status is displayed here for information purposes.
The sensor reacts to variations in the brightness of the video image. The darker the observation area, the higher the value that must be selected. Minimum object size (MOTION+ only) You can specify the number of sensor fields that a moving object must cover to generate an alarm.
Global change You can set how large the global change in the video image must be for an alarm to be triggered. This setting is independent of the sensor fields selected under Select Area . Set a high value if fewer sensor fields need to change to trigger an alarm.
Notice! Select only those areas for reference monitoring in which no movement takes place and that are always evenly lit, as false alarms could otherwise be triggered. 1. Click Select Area to configure the sensor fields. A new window will open. 2. If necessary, click Clear All first to clear the current selection (fields marked yellow).
! Caution! Do not use any special characters, for example & , in the name. Special characters are not supported by the system's internal recording management and may therefore result in the Player or Archive Player programs being unable to play back the recording.
Sender address Enter a unique name for the e-mail sender, for example the location of the device. This will make it easier to identify the origin of the e-mail.
Aux On: defines a standard or custom keyboard ON command. Refer to User Command Table, page 151 for a list of valid commands. Note : Only commands 1, 8, 18, 20, 43, 60, 80, 86 are supported. Support for the remaining commands is scheduled for a future release.
Some changes only take effect after the unit is rebooted. In this case, the Set button changes to Set and Reboot . 1. Make the desired changes. 2. Click the Set and Reboot button.
! Caution! Multicast operation is only possible with the UDP protocol. The TCP protocol does not support multicast connections. The MTU value in UDP mode is 1,514 bytes. TCP rate control Select On to control the rate of transmission control protocol. Select Off if you do not want to control the TCP rate.
DynDNS Enable DynDNS DynDNS.org is a DNS hosting service that stores IP addresses in a database ready for use. It allows you to select the camera via the Internet using a host name, without having to know the current IP address of the unit. You can enable this service here.
To configure the unit, you must connect the camera directly to a computer using a network cable. This is because communication via the network is not enabled until the Identity and Password parameters have been set and successfully authenticated. Identity Enter the name that the RADIUS server is to use for identifying the camera.
Quality of service The camera offers Quality of Service (QoS) configuration options to ensure fast network response to PTZ data and images. Quality of Service (QoS) is the set of techniques to manage network resources.
Port Assign a different port to each data stream if there are simultaneous data streams at the same multicast address. Enter the port address of the required stream here. Streaming Click the checkbox to activate multicast streaming mode for the relevant stream.
Maximum image width Enter a number for the maximum width, in pixels, for the saved images. Accounts In order to configure image posting, and to save and retrieve JPEG images, you must create an Account in which to save and access them. You can create a maximum of four (4) accounts.
The preferred method to update your camera is through a direct connection between the camera and a PC. This method entails connecting the Ethernet cable from the camera directly to the Ethernet port of a PC. If the direct-connect method is not practical, you can also update the camera through a Local Area Network (LAN).
1. Enter the full path of the file to upload or click Browse to select the required file. 2. Next, click Upload to begin transferring the file to the unit. 3. Once all files have been successfully uploaded, the unit must be rebooted. In the address bar of your browser, enter /reset after the IP address of camera (for example 192.
Operation Using the AUTODOME Camera The AUTODOME 7000 transmits PTZ control commands and images over a TCP/IP network. It also allows users to configure the camera display settings, camera operating settings, and to configure the network parameters. The camera incorporates a network video server in the IP module.
Maximum Number of Connections If you do not connect, the unit may have reached its maximum number of connections. Depending on the unit and network configuration, each camera can have up to 50 Web browser connections or up to 100 connections via the Bosch Video Management System (BVMS).
2 Tilts the camera down 9 Focus near² 3 Pans the camera to the left 10 Iris close² 4 Pans the camera to the right 11 Iris open² 5 Pans and tilts the camera in all directions 12 Sets the pre-set sce.
Triggering Relay You can switch connected units using the relays in the camera (for example, lights or door openers). 4 To activate this, click the icon for the relay next to the video image.
1 Command number field 2 Keypad (numbers 0-9) 3 Show a preset scene 4 Set a preset scene 5 Initiates a command 6 Deletes a number in the Command Number field 7 Used to select a menu item 8 Stops a command Notice! Some commands (such as Set 110, Set 899) that were “SET” commands in previous AUTODOME models are no longer “SET” commands.
2. Click the Show scene button. Notice! For more information about the camera settings and controls, click the Help on this page? link to open the online help. LIVE page Special Functions The camera offers special command buttons on the LIVE page. Scan 360° Click this button to start a continuous 360° pan.
Recording Video Sequences You can save sections of the video sequence currently shown on the LIVE page on your computer's hard drive. The icon for recording video sequences is only visible if the unit is configured to enable this process. 4 Click the icon to start recording.
Selecting Recordings All saved sequences are displayed in a list. A track number is assigned to each sequence. Start time and stop time, recording duration, number of alarms, and recording type are displayed. To play back recorded video sequences: 1. Select Recording 1 or 2 in the drop-down menu.
Using Intelligent Tracking Configuring Intelligent Tracking The camera utilizes the built-in Intelligent Video Analytics (IVA) to continuously follow an individual or object even if it passes behind a Privacy Mask or a stationary object.
– Mount the camera in the most stable position. Avoid locations affected by vibrations, such as those caused by a roof-top air conditioner. These vibrations may cause complications when the camera zooms-in on a target. – Use the pendant arm mount, if possible.
If the Intelligent Tracking feature is set to Auto or Click, the live video image displays an eye icon with a symbol that conveys the state of Intelligent Tracking activity: Graphic Description Explanation White eye, flashing Intelligent Tracking is actively following a target.
Recommended Use of Your Camera Bosch recommends that you consider the following in order to optimize the life of your Bosch camera. Notice! Refer to the document “AUTODOME_OperationGuidelines_2014.pdf” for guidelines for operating your camera using Guard Tours and Preset Tours.
Troubleshooting If you experience difficulties operating your AUTODOME camera, refer to the following. If the guidelines do not enable you to solve the problem, contact an authorized technician. Problem Questions to Ask/Actions to Resolve the Problem Need to remove trim ring.
Problem Questions to Ask/Actions to Resolve the Problem Picture is dark – Check that the Gain Control is set to High via the Settings menu. If O.K., then: – Check that the Auto Iris Level is set to the appropriate level via the Settings menu. If O.
Maintenance The bubble is made of Acrylic or Polycarbonate, depending on the application. Polycarbonate bubbles provide high impact resistance, and its optical clarity is comparable to glass or acrylic, although its surface is much softer. All bubbles require special care when handling and cleaning to avoid scratches.
Cleaning the Bubble Exterior The exterior of the bubble is hard coated for extra protection. If cleaning becomes necessary, only use cleaning solutions and cloths suitable for cleaning safety glass lenses. Dry the bubble thoroughly with a dry nonabrasive cloth to prevent water spots.
Technical data For product specifications, see the datasheets for AUTODOME IP 7000 Series and for AUTODOME HD 7000 Series, available on the appropriate product pages of the Online Product Catalog at www.boschsecurity.com. 18 150 en | Technical data AUTODOME IP 7000 HD 2014.
User Command Table Notice! Some of the following commands may not apply to your camera. Locked Alarm Rule Output Function Key Comm No. Command Description Y On/Off 1 Scan 360° Auto Pan without limits.
Locked Alarm Rule Output Function Key Comm No. Command Description Y On/Off 94 Set Azimuth Zero Point Sets the zero degree pan position. On/Off 95 Display Azimuth/ Elevation Readings On–Displays azi.
.
Bosch Security Systems, Inc. 850 Greenfield Road Lancaster, PA, 17601 USA www.boschsecurity.com © Bosch Security Systems, Inc., 2014 Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bosch VG5-7220-EPC4 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bosch VG5-7220-EPC4 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bosch VG5-7220-EPC4 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bosch VG5-7220-EPC4 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bosch VG5-7220-EPC4, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bosch VG5-7220-EPC4.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bosch VG5-7220-EPC4. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bosch VG5-7220-EPC4 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.