EN Installation Guide ICP-CC488 Control Panel ICP-CC488.
ICP-CC488 | Installation Guide | Notices EN | 2 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Copyright Notice Unless otherwise indi cated, this publica tion is the copyright of Bosch Security Systems, Inc. (“ Bosch ”). All rights are reserved.
ICP-CC488 | Installation Gui de | Contents EN | 3 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Contents 1.0 Introduction ........... .......... ........... .......... ........... .8 1.1 ICP-CC488 Features ........ ............ ......... .....
ICP-CC488 | Installation Gui de | Contents EN | 4 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 7.4.9 Command 999 – Display the Panel Type or Software Version Number .................. ......... 39 7.5 Disable Factory Defaults ....... ......
ICP-CC488 | Installation Gui de | Contents EN | 5 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 15.27 System Status Reporting Options ........ ....... 69 15.28 Test Reporting Time ............... ......... .......... .. 69 15.29 Test Reporting Dialer Options .
ICP-CC488 | Installation Gui de | Contents EN | 6 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 24.4 New Zealand Telepermit Notes........... ..... 100 24.5 A-Tick................... ............ ......... ............ ....... 101 25.0 Programming Sheets .
ICP-CC488 | Installation Gui de | Contents EN | 7 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Table 40: Ex ample Rep orting in 4 + 2 Form at ... 44 Table 41: 4 + 2 Reporting Format............ ............ . 44 Table 42: 4 + 2 Tran smission Code Descr iptions45 Table 43: Point ID Codes .
ICP-CC488 | Install ation Gu ide | 1.0 Introdu ction EN | 8 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 1 .0 Int roduct ion Congratulations on sele cting the ICP-CC488 Co ntrol Panel for your installat ion.
ICP-CC488 | Install ation Gu ide | 1.0 Introdu ction EN | 9 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 1.2 Quick Start The following steps allow you to use the ICP-CC 488 Control Panel with factory default values. The defau lt values allow the control panel to communicate in the Contact ID format.
ICP-CC488 | Install ation Guide | 2.0 Codepad Indicat ors EN | 10 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 1.2.3 Zone Types There are thirteen zone types to cho ose from when programming zones for the ICP-CC488 Co ntrol Panel. Refer to Section 14.
ICP-CC488 | Install ation Guide | 2.0 Codepad Indicat ors EN | 11 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 MAINS Indicator The MAINS indicator display s whether the system’s AC MAINS supply is normal or fa iled.
ICP-CC488 | Install ation Guide | 2.0 Codepad Indicat ors EN | 12 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 • Section 3.5 to arm the system in STAY Mode 2. • Section 5 .1.5 to use the Installer Code to set zones to be automatically isolated in STAY Mo de 2.
ICP-CC488 | Install ation Guide | 2.0 Codepad Indicat ors EN | 13 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Table 10: Area On/Off Indicators Indicator Definition On The area is armed in AWAY Mode or STAY Mode 1.
ICP-CC488 | Installation Guid e | 3.0 System Operations EN | 14 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 3.0 Syst em Operat ions This section e xplains the ge neral operatio ns of the system: arming and disarming the system in the three modes, isolating zones, in itiating codepad alarms, and determining a fault.
ICP-CC488 | Installation Guid e | 3.0 System Operations EN | 15 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 To arm the system in ST AY Mode 1 (method one): 1. Enter your code and press [STAY]. 2. Two beeps sound and the STAY indicator is lit.
ICP-CC488 | Installation Guid e | 3.0 System Operations EN | 16 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 The indicators for any zones that are programmed to be automa tically is olated in STAY Mod e 2 fla sh until the Exit Time expires. At the end of Exit Time, the zone indicators are extinguished and the codepad sounds one short beep.
ICP-CC488 | Installation Guid e | 3.0 System Operations EN | 17 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 3.9 Codepad Fire Alarm An audible codepad Fire Alarm activates when a user presses [4] and [ 6] on the remote co depad simultaneously.
ICP-CC488 | Installation Guid e | 3.0 System Operations EN | 18 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 5. Press [AWAY]. Two beeps sound and the system returns to the disarmed state. The indicators for th e selected zones continue to flash until the n ext time t he system i s disarm ed.
ICP-CC488 | Installation Guid e | 3.0 System Operations EN | 19 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Table 14: System FAULT indicators Indicator Fault Descr iption 1 Low battery This fault register s when the system de tects a low c apacity backup battery.
ICP-CC488 | Installation Guide | 4.0 Remote Radio Transmitter Operations EN | 20 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Table 15: Fault A nalysi s Condit ions Zone Indicator Fault Descr.
ICP-CC488 | Installation Guide | 4.0 Remote Radio Transmitter Operations EN | 21 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Before a hand-held radio transmitter can operate the control panel, you must teach the transm itter’s radio code to the contro l panel.
ICP-CC488 | Installation Guide | 5.0 System Func tions EN | 22 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 To delete a remote radio User Code: 1. Enter the Master Code an d press [1][AWAY]. Three beeps sound and the STAY and AWAY indica tors flas h.
ICP-CC488 | Installation Guide | 5.0 System Func tions EN | 23 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Example To program RF wireless d evice number 3 who se 9- digit ID number is 000094946, ente r [1 2 3 4 0][AWAY ][3][AWAY] [0 0 0 0 9 4 9 4 6][AWAY] To delete an RF wirele ss device: 1.
ICP-CC488 | Installation Guide | 5.0 System Func tions EN | 24 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Table 21: Codepad Indica tors When Changin g Phone Numbers Zone Indicator s MAINS Digit 1 2 3 4 5 6 7 8 Indicat or 0 X 1 X 2 X 3 X 4 X 5 X 6 X 7 X 8 X 9 X X * X X # X X Pause X X B r e a k X X 15 X X 5.
ICP-CC488 | Installation Guide | 5.0 System Func tions EN | 25 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 To program the telco disarm sequence: 1. Enter the Installer Co de and pres s [3][AWAY]. Three beeps sound and the STAY and AWAY indica tors flas h.
ICP-CC488 | Installation Guide | 5.0 System Func tions EN | 26 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Table 23: Telephone Monitor Mode Indications Zone LED Dialing Event 1 Telephone lin.
ICP-CC488 | Installation Guide | 5.0 System Func tions EN | 27 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 5.2 Master Code Functions Master Code functions allow those us ers that have the appropriate prior ity level to perform ce rtain supe rvisor y level func tions.
ICP-CC488 | Installation Guide | 5.0 System Func tions EN | 28 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Table 27: User Numbers Displaye d by the Codepad Indica tors User Zone Indicator s Number 1 2 3 4 5 6 7 8 1 X 2 X 3 X 4 X 5 X 6 X 7 X 8 X Example To delete user code number 3, enter: [2 5 8 0 1][AWAY ][3][AWAY][STAY] 5.
ICP-CC488 | Installation Guide | 5.0 System Func tions EN | 29 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Table 29: Domestic Dialing Digits Digit Required Number to Program Digit Required N.
ICP-CC488 | Installation Guide | 5.0 System Func tions EN | 30 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 4. Press [STAY][2][AWAY]. Two beeps sound and the system returns to the disarmed state.
ICP-CC488 | Installation Guide | 5.0 System Func tions EN | 31 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Example If Output 2 is programmed as 291000 in Locations 443 to 448, the Master Code ho lder can turn o n this output by entering: [2 5 8 0 5][AWAY ][2][AWAY][AWAY] To turn an output off from the re mote codepad: 1.
ICP-CC488 | Installation Guide | 5.0 System Func tions EN | 32 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 The al ar m memory play s back in this order : Table 33: Event Memory Playb ack Seq.
ICP-CC488 | Installation Guide | 5.0 System Func tions EN | 33 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 For more inform ation, refer to Section 5.1.5 S etting STAY Mode 2 Zones on page 25 (using the Installer Code function) or Section 5.2.
ICP-CC488 | Installatio n Guide | 6.0 Remote Arming by Telephon e EN | 34 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 To dete rmi ne the are a to which th e code pad belongs: 1. Press and hold [8] unti l two beeps sound. A zone indicator lights to show the area to which the codepad belongs.
ICP-CC488 | Installatio n Guide | 7.0 Programming EN | 35 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 When you enter Installer’s Programming Mode, you are automatically positioned at Location 000, the first digit of the Primary Telephone Number for Receiver 1.
ICP-CC488 | Installatio n Guide | 7.0 Programming EN | 36 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 If you do not e nter Installer’s Pro gramming Mode first, co nnecting the CC891 Programming Key to the cont rol panel when the pro gramming key memory is blank corrupts the contro l panel’s memory.
ICP-CC488 | Installatio n Guide | 7.0 Programming EN | 37 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 3. Enter [9 5 9 #]. Two beeps soun d afte r a s ucces sful t est of the programming key. A long b eep indicates that the programming key data is c orrupt and must be erased to clear the corrupt data.
ICP-CC488 | Installatio n Guide | 7.0 Programming EN | 38 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 3. Enter [9 6 3 #]. Two beeps sound after the programming key’s data is successfully copied to the control panel. A long beep in dicates that the programming key is corrupt and must be era sed to clear the corrupt data.
ICP-CC488 | Installatio n Guide | 7.0 Programming EN | 39 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Example (Auto Step E nabled) To enter the Prim ary Telephone Numb er 02 (pause) 9672 1055 when auto step is enable d: 1. Press [0 #]. You are positioned at Location 000 (the Primary Telephone Number for Receiver 1).
ICP-CC488 | Install ation Gu ide | 8.0 Alarm L ink Soft ware EN | 40 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 If you are required to disable the ability restore the control pa nel to its defau lt settin gs, a spec ial procedure eliminates the possibility of acci dentally setting this option.
ICP-CC488 | Install ation Gu ide | 8.0 Alarm L ink Soft ware EN | 41 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 • Program the Call Back Telephone Number in Locations 159 to 174 (refer to Section 11 .9 on page 51). • Disable Optio n 1 in Locatio n 180 (refe r to Section 8.
ICP-CC488 | Installatio n Guide | 9.0 Domestic Dia ling EN | 42 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 2 – Enable Alarm Link Call Back If thi s option is select ed and a c allback tel.
ICP-CC488 | Install ation Gu ide | 10 .0 Dialer R eporting Formats EN | 43 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 9.2 Setting Up and Programming Domestic Reporting Programming the control panel for domestic reporting is e xtremely sim ple when usin g the Insta ller’ s Pro gramm ing Co mm and 965.
ICP-CC488 | Install ation Gu ide | 10 .0 Dialer R eporting Formats EN | 44 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Table 39: Contact ID Format Breakdown Subscriber ID Number Qualifier Ev.
ICP-CC488 | Install ation Gu ide | 10 .0 Dialer R eporting Formats EN | 45 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Table 42: 4 + 2 Transmissi on Code Descriptions Code Description SSSS S.
ICP-CC488 | Install ation Gu ide | 10 .0 Dialer R eporting Formats EN | 46 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Table 43 : Point ID Co des Point ID Event Description Event Code Explanation Section Zones 1 to 8 Burglary Zone 130 Burglary 14.
ICP-CC488 | Install ation Gu ide | 10 .0 Dialer R eporting Formats EN | 47 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Figure 9: Basic Pager Display 1 – Subscriber ID number 2 – Zone sta.
ICP-CC488 | Install ation Guide | 11 .0 Dialer Inform ation EN | 48 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 10.2 Basic Pager Display In formation The Pag er form at supp orts onl y eig ht zones.
ICP-CC488 | Install ation Guide | 11 .0 Dialer Inform ation EN | 49 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Table 45: Dialing Digits Digit Required Number to Program Digit Required Number to Progra m terminator 0 8 8 1 1 9 9 2 2 0 10 3 3 * 11 4 4 # 12 5 5 4 sec pause 13 6 6 break 14 7 7 15 15 11.
ICP-CC488 | Install ation Guide | 11 .0 Dialer Inform ation EN | 50 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 2 – 1400 Hz 1400 Hz Handshake Tone is required to communicate in Ademco Lo Speed Format or Domestic Dialing Format. 3 – 2300 Hz Reserved.
ICP-CC488 | Install ation Guide | 11 .0 Dialer Inform ation EN | 51 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Table 46: Telco Arm/Disarm Diali ng Digits Digit Required Number to Program Di.
ICP-CC488 | Install ation Gu ide | 12 .0 Dialer Options EN | 52 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Program the Ring Count to 14 to enable Answering Machine Bypass in the secondary mode. In this case, call the control panel and allow the phone to ring no more than twice and hang u p.
ICP-CC488 | Install ation Gu ide | 12 .0 Dialer Options EN | 53 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 2 – Remote Armi ng by Telephone A llowed If you select this option, you can remotely arm the system using a standard telephone b y pressing [*] on your touch-tone telephone.
ICP-CC488 | Installation Guide | 13.0 Access Codes EN | 54 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 2 – Lockout Telephone Line Fail Alarm Selecting this option allows an audib le alarm only once per arming cyc le when the co ntrol panel de tects the telephone line is cut or disconnected.
ICP-CC488 | Installation Guide | 13.0 Access Codes EN | 55 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Location 185 to 264 Location Default User Code 1 185 2 186 5 187 8 188 0 Priority Level.
ICP-CC488 | Install ation Guide | 14 .0 Zone I nformatio n EN | 56 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Master Code Functions The user has ac cess to all Master Cod e functions. Refer to Section 5.2 Master Code Functions on page 26 for more information.
ICP-CC488 | Install ation Guide | 14 .0 Zone I nformatio n EN | 57 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 This configuratio n is suitable on ly for normally-closed (N/C) con tacts.
ICP-CC488 | Install ation Guide | 14 .0 Zone I nformatio n EN | 58 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Figure 13: Split EOL Resistors Using Two N/O Conta cts 2 3 1 4 5 6 7 8 8 1 – +1 2 V 2 – Zone Input 3 – Zone 4 – EOL 3k3 5 – EOL 6K8 6 – EOL 1K5 7 – EOL 4K7 8 – N/O 14.
ICP-CC488 | Install ation Guide | 14 .0 Zone I nformatio n EN | 59 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Location 267 to 378 (co ntinued) Location Default Zone #07 (De fault = Insta nt.
ICP-CC488 | Install ation Guide | 14 .0 Zone I nformatio n EN | 60 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 14.3.2 Zone Types The zone t ypes are li sted in Table 48 .
ICP-CC488 | Install ation Guide | 14 .0 Zone I nformatio n EN | 61 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 13 – 24-Hour Fire Zone A 24-Hour Fire Zone (Contact ID Even t Code 110) is always ready to ac tivate the dia ler, horn speaker, bell, and strobe, whether the system is armed or disarmed.
ICP-CC488 | Install ation Guide | 14 .0 Zone I nformatio n EN | 62 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 The ICP-CC488 Control Panel performs lockout differently than othe r control pane ls because only t he first zone to activate an alarm is locked out.
ICP-CC488 | Install ation Guide | 14 .0 Zone I nformatio n EN | 63 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 5 – Latc hing A rm in STA Y Mod e 1 The system is armed in STAY Mode 1 when using the latching keyswitch inpu t. Arming the system in AWAY Mode or disarming the system is not permitted from the Ke yswitch Zone.
ICP-CC488 | Install ation Guide | 14 .0 Zone I nformatio n EN | 64 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 When isolating 24-Hour Zones, the s ystem automatically sends a Zone Bypass Report when the zone is selected to be iso lated. All non-24-Hour zones send a Bypass Report only when the system is armed.
ICP-CC488 | Install ation Guide | 15 .0 Syst em Re porting Inform ation EN | 65 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 When the Swinger Shutdown Count is reached, all zones that were activated are locked ou t according to their individual lo ckout settings.
ICP-CC488 | Install ation Guide | 15 .0 Syst em Re porting Inform ation EN | 66 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 A Sensor Trouble Restore Report is sent for Burglary Zones when the zone is resealed or the next time the system is disarmed (whichever happens first).
ICP-CC488 | Install ation Guide | 15 .0 Syst em Re porting Inform ation EN | 67 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 An RF Receiver Trouble Report (C ontact ID Event Code 355) is sent.
ICP-CC488 | Install ation Guide | 15 .0 Syst em Re porting Inform ation EN | 68 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Restore Repo rts are not sent for this event. If Codepad Panic Reports are not required, program Locations 405 and 406 as 0.
ICP-CC488 | Install ation Guide | 15 .0 Syst em Re porting Inform ation EN | 69 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 15.2 4 Sys tem Stat us – L ow B att ery Report Location 420 to 4.
ICP-CC488 | Install ation Guide | 16 .0 Program mable Outputs EN | 70 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 When p rogr amming Test Re port o ption s, spe cify the hour and minute of the day the report is required, and how often to send the report.
ICP-CC488 | Install ation Guide | 16 .0 Program mable Outputs EN | 71 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 16.1 Redirecting Outputs to the Codepad Buzzer Multiple output even t types can be d irected to the codepa d buzze r so that th e buzzer can in dicate a number of events.
ICP-CC488 | Install ation Guide | 16 .0 Program mable Outputs EN | 72 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 0,12 Entry Warning + Day Alarm Resetting This output combines En try Warning and Day Alarm Resetting so that either of these two even ts activates the output.
ICP-CC488 | Install ation Guide | 16 .0 Program mable Outputs EN | 73 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 1,7 Sensor Watch Alarm This output operates when the Sensor W atch Count is reached. Refer to Section 14.3.5 Zone Options 1 on page 61 for more informatio n on programming zones for sensor watch.
ICP-CC488 | Install ation Guide | 16 .0 Program mable Outputs EN | 74 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 2,7 Fire Alarm Verificati on This feature is used on some commercial fire control panels to reduce false alarms from smoke detectors.
ICP-CC488 | Install ation Guide | 16 .0 Program mable Outputs EN | 75 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 3,5 Mimic Zone 1 3,6 Mimic Zone 2 3,7 Mimic Zone 3 3,8 Mimic Zone 4 3,9 Mimic Zone 5 3,10 Mimic Zone 6 3,11 Mimic Zone 7 3,12 Mimic Zone 8 These output types mimic the zone inputs.
ICP-CC488 | Install ation Guide | 16 .0 Program mable Outputs EN | 76 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Set DIP Switch 2 to the ON position for the Area 2 codepa d to op erate co rrectly. Refer to Figur e 16 on page 76 for the location of the DIP switches on the back of the codepa d.
ICP-CC488 | Installation Guide | 17.0 Sys tem Event Timers EN | 77 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 10 – N ormally Low, O ne-Sh ot Open This on e-shot pola rity i s norm ally 0 V and swit ches to open circuit when the ev ent occurs.
ICP-CC488 | Installation Guide | 17.0 Sys tem Event Timers EN | 78 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 17.1 Programming Ent ry/Exit Timers There are two programming locations for Entry Timer 1, Entry Timer 2, Ex it Time for AWAY Mode, and Entry Guard Time for STAY Mode.
ICP-CC488 | Installation Guide | 17.0 Sys tem Event Timers EN | 79 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 The Se nsor Wa tch Tim e count er is ac tive on ly when the control panel is disarmed.
ICP-CC488 | Installation Guide | 18.0 Sys tem and Consumer Opti ons EN | 80 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 For part itione d ICP-CC488 Control Panels, both areas are automa tically disarmed at the sa me time each day.
ICP-CC488 | Installation Guide | 18.0 Sys tem and Consumer Opti ons EN | 81 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 4 – Strobe I ndications f or Radio Arm/D isarm This option allows the strobe to indicate when the system is armed and disarmed when remotely operating the system using the DSRF Series RF Receiver.
ICP-CC488 | Installation Guide | 18.0 Sys tem and Consumer Opti ons EN | 82 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 2 – Ignore AC Fail If this option is selected, the M AINS indicator does not flash and the codepad does not beep every minute when the AC MAINS is disconnected from the cont rol pane l.
ICP-CC488 | Installation Guide | 18.0 Sys tem and Consumer Opti ons EN | 83 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Program the time that the co ntrol panel au tomatically arms itself in Locations 482 to 485 (refer to Sect ion 17.12 Aut o Arming Ti me on page 79).
ICP-CC488 | Install ation Guide | 19 .0 Part ition ing EN | 84 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 1 9.0 Part it ioning The ICP-CC488 Control Panel includ es the partitioning feature, which can effectively transform your single control panel into two separate areas.
ICP-CC488 | Install ation Guide | 19 .0 Part ition ing EN | 85 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 19.3.1 Partitioning Options 1 Location 500 Default 0 1 First to open/la st to close.
ICP-CC488 | Install ation Guide | 19 .0 Part ition ing EN | 86 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 19.4.1 Zone Allocations for Areas 1 and 2 Location 502 to 517 Location Defau lt Zon.
ICP-CC488 | Install ation Guide | 19 .0 Part ition ing EN | 87 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 19.6.1 Setting U p th e Maste r Parti tioned Codepad as the M ain Codepa d To use t.
ICP-CC488 | Install ation Guide | 20 .0 RF I nformati on EN | 88 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Figure 21: Connections for CP-5 Master Partitioned C odepad and CP- 5 Area Addres.
ICP-CC488 | Install ation Guide | 20 .0 RF I nformati on EN | 89 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 8 – Enable RF Jamming Monitor If this option is selected, the RF receive r monitors the backg rou nd RF le ve ls. If t his leve l rea ches a pr eset limit, the receive r assumes it is being jammed.
ICP-CC488 | Install ation Gu ide | 21 .0 Optional Equipme nt EN | 90 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Then , find t he RF d evice n umber i n Section 20.3 (for devices 1 through 8) on page 89 or S ection 20.4 (for devices 9 through 16) on pa ge 89.
ICP-CC488 | Install ation Gu ide | 21 .0 Optional Equipme nt EN | 91 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 21.3 SS914 EDMSAT Satelli te Siren The EDMS AT Satellit e Siren is a totally self- contained unit incorporating a high-powered siren and a weatherproof strobe.
ICP-CC488 | Installatio n Guide | 22.0 T erminals and Description s EN | 92 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 22.0 T erminals and De script ions 22.
ICP-CC488 | Installatio n Guide | 22.0 T erminals and Description s EN | 93 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 22.2 Glossary Of Terms Table 64: Glossary Term Description 24-hour zone A monitored input where ta mper switche s and emergency switch es can be connected.
ICP-CC488 | Installatio n Guide | 22.0 T erminals and Description s EN | 94 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Table 64: Glossary (continued) Term Description lockout siren A siren that activates only once per zone per arming cycl e.
ICP-CC488 | Installatio n Guide | 22.0 T erminals and Description s EN | 95 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 22.3 D iagram s Figure 23: IC P-CC488 Wiring Diagram 1 – 605 pl ug 2.
ICP-CC488 | Installatio n Guide | 22.0 T erminals and Description s EN | 96 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Figure 24: ICP-CC488 Component Overlay 1 – Socket for tel ecom lead .
ICP-CC488 | Installatio n Guide | 22.0 T erminals and Description s EN | 97 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Figure 25: DSRF Rad io Receiver Wiring Diagram 2 1 1 – ICP-CC488 Control Panel 2 – DSRF Receiver Wiring and Power Up 1.
ICP-CC488 | Installatio n Guide | 22.0 T erminals and Description s EN | 98 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Figure 27: Telecom Connection Diagram for New Zealand 1 3 2 4 5 6 7 8 .
ICP-CC488 | Install ation Guide | 23 .0 Appen dices EN | 99 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 23.0 Append ices 23.1 A ppendi x A – Tel epho ne Anti - Jamming There are many c omp.
ICP-CC488 | Installatio n Guide | 24.0 Spe cifications EN | 100 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Select Option 1 (Send Test Reports only if the system is armed) in Location 428 (refer to Section 18.5 Consumer Options 1 on page 82) and then s et the Test Report Time to be in the middle of the day.
ICP-CC488 | Install ation Guide | 25 .0 Program ming Sh eets EN | 101 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 • Disconnect this equipment imm ediately if it becomes physically damaged and arrange for it s disposal or repair.
ICP-CC488 | Install ation Guide | 25 .0 Program ming Sh eets EN | 102 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Transmission Format for Receiver 2 Location 073 Refer to page 50 1 Contact I.
ICP-CC488 | Install ation Guide | 25 .0 Program ming Sh eets EN | 103 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Installer Code Location 181 t o 184 Refer to pa ge 54 Default 1 2 3 4 User C.
ICP-CC488 | Install ation Guide | 25 .0 Program ming Sh eets EN | 104 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Zones Location 267 to 378 Refer to page 58 Zone 1 Locations 267 to 273 Defau.
ICP-CC488 | Install ation Guide | 25 .0 Program ming Sh eets EN | 105 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Zone Dialer Options Option Description 0 No report required 1 Receiver 1 2 R.
ICP-CC488 | Install ation Guide | 25 .0 Program ming Sh eets EN | 106 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Codepad Pa nic Report Location 405 to 406 Refer to page 67 Default 7 15 Code.
ICP-CC488 | Install ation Guide | 25 .0 Program ming Sh eets EN | 107 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Entr y Guar d Time fo r STAY Mod e Location 472 to 473 Refer to page 78 Defa.
ICP-CC488 | Install ation Guide | 25 .0 Program ming Sh eets EN | 108 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Consumer Options 3 Location 498 Refer to page 83 1 C odepad fault be eps all.
ICP-CC488 | Install ation Guide | 25 .0 Program ming Sh eets EN | 109 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 RF Options Location 599 Refer to page 88 Default 0 1 Sound siren on RF recei.
ICP-CC488 | Install ation Guide | 25 .0 Program ming Sh eets EN | 110 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Disable Factory Default Location 900 Refer to page 39 0 Defaulting enable d .
ICP-CC488 | Install ation Guide | 25 .0 Program ming Sh eets EN | 111 Bosch Security Systems, Inc. | 12/08 | F01U08 9457-02 Country Code Country Code Country Code Country Code Country Code Italy 2 5 J.
ICP-CC488 | Install ation Guide | Index EN | 112 Bosch Secur ity Systems, Inc. | 12/ 08 | F01U089457-02 Notes.
ICP-CC488 | Install ation Guide | Index EN | 113 Bosch Secur ity Systems, Inc. | 12/ 08 | F01U089457-02 Index A AC Mains Fail In 1 Hour ..... .......... ......... ............ ......... .......... .. 81 Ignore Fail Indication ........... .......... ..
ICP-CC488 | Install ation Guide | Index EN | 114 Bosch Secur ity Systems, Inc. | 12/ 08 | F01U089457-02 Programming Telephone Numbers ......... .......... .. 48 Subscriber ID Number For Receiver 1 ............. .. 50 Telco Arming Sequence ....... ....
ICP-CC488 | Install ation Guide | Index EN | 115 Bosch Secur ity Systems, Inc. | 12/ 08 | F01U089457-02 Night Arm Station ................. ............ ......... .......... .. 91 Programming Key ..... .......... ......... ............ ......... .....
ICP-CC488 | Install ation Guide | Index EN | 116 Bosch Secur ity Systems, Inc. | 12/ 08 | F01U089457-02 Enable "User Code + 0 + AWAY " To Arm/Disarm Both Areas ................... ............ ......... .......... ......... 85 Lock Area 1 To Receiver 1 & Lock Area 2 To Receiver 2.
ICP-CC488 | Install ation Guide | Index EN | 117 Bosch Secur ity Systems, Inc. | 12/ 08 | F01U089457-02 Restore Code ........... .......... ........... .......... ......... ....... 66 Restore Report ........ ......... ............ .......... .........
© 2008 Bosch Security Systems, Inc. F01U089457-02 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450-9199 USA www.boschsecuri ty.com.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bosch Appliances ICP-CC488 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bosch Appliances ICP-CC488 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bosch Appliances ICP-CC488 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bosch Appliances ICP-CC488 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bosch Appliances ICP-CC488, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bosch Appliances ICP-CC488.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bosch Appliances ICP-CC488. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bosch Appliances ICP-CC488 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.