Manuale d’uso / di manutenzione del prodotto 2074FR del fabbricante Bloomfield
Vai alla pagina of 28
PRINTED IN UNITED STATES OF A MERIC A p/n 73573 Rev. V ECN-12817 M651 05 0208 cps 651 OWNERS MANUAL for E-Max™ DECANTER COFFEE BREWERS MOD EL S 2012 2016 2016EX 2072 2072L 2072FR 2072FRL 2074 2074L .
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged b y skilled personnel before le aving the factory. Upon acceptance of this shipm ent, the transportation company assumes full responsibility for its safe delivery.
TABLE OF CONTENTS SPECIFIC ATIONS Thank You for purc hasing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance w ill ensure that it gives you the very best performance and a long, economical service life.
FE AT U R E S AN D O P E R AT I N G CO N T R O L S 2.
WARNING: Electric Shock Hazard All servicing requiring access to non-insu lated components must be performed by qualified service personnel. Do not open any access panels wh ich require the use of tools. Failure to heed this warning can re su lt in electrical shock.
INSTALLATION INSTRUCTIONS RE A D THIS CAREFULL Y BEFORE ST A R TING THE INST A LLA TIO N UNPACKING & INITIAL INSPECTION 1. Unpack the unit. Inspec t all components for completeness and condition. Ensure that all pack ing materials have bee n rem oved from the unit.
INSTALLATION INSTRUCTIONS (continued) NOTE: This equipment must be installed to comply with applicable federal, state an d local plum bing codes an d ordinanc es. WARNING ELECTRIC SHOCK HAZARD: Brewer must be properly grounded to prevent possible shock hazard.
OPERATION IMPORTANT: All E-Max™ brewers are tested and set a t the fa ctory . If programming adjust- ments are necessary, refer to the E -Ma x™ Programming Manual (p/n/73674). To over-ride th e Br ew Wait mode , press and hold the BR EW key for 3 second s when the brewer is in Bre w Wait mode (i.
OPERATION (continued) WA RN IN G: Burn Hazard. This appliance dispenses very hot liquid. Serious bodily injury from scalding can occur from contact with dispensed liquids. C AUTION: B urn Hazard To avoid splashing or overflowing ho t liquids, ALWAYS use an empty decanter b efor e starting the brew cycle.
PROGRAMMING FEATURES AND OPTIONS 1. View Water Temperature in Tank: To view the water tem perature on the scre en, the E-Ma x™ brewer must be ON, and not brewing or in the filling mode. Press and hold the 4th key, and depress the 6th key. The actual wa ter temperature w ill be displayed for 3 seconds.
8. Clock A. Time – Battery Backup. The E-Max™ has a batter y backup system which will maintain the proper time during power failures, or when the brewer is unplugged (even for very prolonged periods of time).
OPERATION (continued) 12. View Filter Statistics: To view filter st atistics, tu rn the bre wer off. Pr ess and hold the 1st ke y (Brew), and depress the 3rd (ON/OFF) key. Total water volume will be displayed (TotalVol.). Press the 3rd k ey to view the Filter Life (F ltrLife:).
CLEANING I NSTRUCTIONS PROCEDURE: Clean Coffee Br e wer PRECAUTIONS: Disconnect bre wer from electric power. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mi ld Detergent, Clean So ft Cloth or Sponge Bristle Brush 1. Dis connect bre wer from electric po w er.
FUNCTION 1. W ater enters at the inlet fitt ing of the fill solenoid (32). The s olenoid admits water via a command from the controller. N OTE: The solenoid has an inter nal strainer. To clean the s trainer: Shu t off water s upply. Unscre w the plasti c cap protruding f rom the rear of the brewer.
SERVICING IN STRUCTIONS — PLUM BING (continued) 13 ITEM DESCRI PTIO N P ART N0. USED ON 1 2 ASS EMB L Y , W A TER T AN K (120 V) 835 00 201 2 , 20 72 20 15 , 2 07 5 6 G ASK ET , T ANK LID 834 9 9 ALL 9 T ANK L ID 83 5 04 ALL 10 RET A INING CLIP , T ANK LID 8350 6 ALL 1 1 HO S E, OV ERF LO W ( 2 pc SI LI CON E 4.
SERVICING INST RUCTIONS - ELECTRIC AL FUNCTION 1. Pressing th e POWER k ey energizes the unit. The POWER LED will glow whenever the unit is ON . 2. Autom atic fill is accomp lished via a FI LL SOLENOID (32) and a WATER LEVEL PROBE (7). The probe senses ground t hrough the water in the tank.
SERVICING INSTR UCTIONS - ELECTRIC AL (continued) 15 ITEM DE S CRI PTIO N P ART N0. USED ON 3 P R O BE, TE MPE R A TUR E 83480 AL L 4 T HE R M O ST A T , HI-L IM I T SA F E TY (120 V ) 83949 2 01 2, 2.
SERVICING INSTRUCTIONS — DE -LIMING WA TER HEATER TA NK 1. Disconn e ct br e wer form the electrica l sup pl y. Turn off t he water suppl y and dis connect water suppl y from the bre wer inlet fitting. 2. Rem ove the top panel or top wa rmer section to gain access to internal components.
TROUBLESHOOTING SUGGESTIONS If the E-Max™ goes into the error diagnostic mode as outlined below , it will likely be necessa ry to reset the brew er in ord er to test individual components.
EXPLODED VIEW & PARTS LIST 18 3-WARMER IN-LINE BREWER MODELS: 2012, 2016.
EXPLODED VIEW & PARTS LIST (continued) 19.
EXPLODED VIEW & PARTS LIST (continued) 20 3-WARMER STEP-UP BREWER MODELS: 2072, 2074.
EXPLODED VIEW & PARTS LIST (continued) 21.
WIRING DIAGRA MS White #1 1 White #1 1 White #10 Red #6 Black #9 Black #9 Brown #1 # 1 # 2 # 3 White White White #1 1 Red #4 Red Blue Blue #5 Orange #3 Oran ge #7 Orange #8 Red #6 Brown #1 Blue #2 Bla.
WIRING DIAGRA MS (continued) 23 Black #16 Orange #3 B l u e # 7 B l a c k # 8 Red #14 1 2 3 4 Red #6 Brown #1 Blue # 2 Black #9 White #12 White #10 White #1 1 T ank Heater 3200 W att 240 V olt White #.
WIRING DIAGRAMS (continued) 24 IN-LINE BREWER 240 VOLT.
NOTES 25.
PRINTED IN UNITED STATES OF AMERICA Bloo mf iel d Indu stri es, Inc . Division of Carrier Co mmercial Refrigeration In US and Can ada T elep hone: 775 -689- 5700 Fa x: 888-4 92-2783 Fa x: 800-3 56-5142 () websi te: www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bloomfield 2074FR è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bloomfield 2074FR - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bloomfield 2074FR imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bloomfield 2074FR ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bloomfield 2074FR, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bloomfield 2074FR.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bloomfield 2074FR. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bloomfield 2074FR insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.