PRINTED IN UNITED STATES OF A MERIC A p/n 73902 Rev. F ECN- 12817 M653 05 0208 cps 653 OWNERS MANUAL for E-Max™ TEA BREWERS MOD EL S 2030 Includes: Installation Operation Use & Care Servicing Instructions Mode l 2030 Tea Brewer with optional 8799 Dispenser E-Max BREWERS are cov ered under U.
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged b y skilled personnel before le aving the factory. Upon acceptance of this shipm ent, the transportation company assumes full responsibility for its safe delivery.
TABLE OF CONTENTS SPECIFICATIONS Thank You for purc hasing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance w ill ensure that it gives you the very best performance and a long, economical service life.
FE AT U R E S AN D O P E R AT I N G CO N T R OL S 2 Features & Operating Contro ls.
WARNING: Electric Shock Hazard All servicing requiring access to non-insu lated components must be performed by qualified service personnel. Do not open any access panels wh ich require the use of tools. Failure to heed this warning can re su lt in electrical shock.
INSTALLATION INSTRUCTIONS RE A D THIS CAREFULL Y BEFORE ST A RTING THE INST AL L A TION UNPACKING & INITIAL INSPECTION 1. Unpack the unit. Inspec t all components for c ompleteness and condition. Ensure that all pack ing materials have been rem oved from the unit.
INSTALLATION INSTRUCTIONS (continued) NOTE: This equipment must be installed to comply with applicable federal, state an d local plum bing codes an d ordinanc es. WARNING ELECTRIC SHOCK HAZARD: Brewer must be properly grounded to prevent possible shock hazard.
OPERATION IMPORTANT: All E-Max T™ brewers are tested and set a t the facto ry . If programming adjust- ments are necessary, refer to the E -Ma x™ Programming Manual (p/n 73674). To over-ride th e Br ew Wait mode , press and hold the BR EW key for 3 second s when the brewer is in Bre w Wait mode (i.
OPERATION (continued) WA R N IN G: Burn Hazard. This appliance dispenses very hot liquid. Serious bodily injury from scalding can occur from contact with dispensed liquids. C AUTION: B urn Hazard To avoid splashing or overflowing ho t liquids, ALWAYS use an empty dispenser before starting the brew cycle.
PROGRAMMING FEATURES AND OPTIONS 1. View Water Temperature in Ta nk: To view the water tem perature on the screen, E-Max T™ bre we r must be ON, and not brewing or in the filling mode. Press and hold the 4th key, and depress the 6th k ey . The actual water temperature w ill be displayed for 3 seconds.
8. Cl ock A. Time – Battery Backup. The E-Max T™ has a battery back up sy stem which will maintain the proper time during power failures, or when the brewer is unplugge d (e ven for very prolonged periods of time).
OPERATION (continued) 10 12. View Fil ter Statistics: To view filter statistics, turn the br e wer off. P ress and hold the 1s t ke y (Brew), and depress the 3rd (ON/OFF) k ey. Total water volume will be displa yed (TotalVol.). Press the 3rd k ey to view the Filter Lif e (F ltrLife :).
CLEANING I NSTRUCTIONS PROCEDURE: Clean Coffee Br e wer PRECAUTIONS: Disconnect brew er from electric power. Allow brewer to cool. FREQUENCY: Dail y TOOLS: Mi ld Detergent, Clean Sof t Cloth or Sponge Bristle Brush 1. Disconnect brewer from electric power.
FUNCTION 1. W ater enters at the inlet fitt ing of the fill solenoid (32). The s olenoid admits water via a command from the controller. N OTE: The solenoid has an inter nal strainer. To clean the s trainer: Shu t off water s upply. Unscre w the plast ic cap protruding f rom the rear of the brewer.
SERVICING IN STRUCTIONS — PLUM BING (continued) 13 ITEM DESCRIPTI ON P ART N0. USED ON 1 2 ASS E MBL Y , WA TER T ANK (120 V) 835 0 0 2030 6 GAS KET , T ANK LID 83499 2 030 9 TANK LI D 835 04 2 03 0 10 RET A INING CLIP , T ANK LID 83506 2 030 1 1 HO S E, V ENT (SIL I C O N E 4.
SERVICING INSTRUCTIO NS - ELECTRICAL FUNCTION 1. Pressing th e POWER k ey energizes the unit. The POWER LED will glow whenever the unit is ON . 2. Automatic fill is accomplished via the "FILL" section of the INLET SOLENOID (32) and a WATER LEVEL PROBE (7).
SERVICING INSTRUCTIONS - ELECTRICAL (continued) 15 ITEM DESCR IP TI ON P ART N0 . USED ON 3 PROBE, TEMPERA TURE 834 80 ALL 4 T HER M O ST A T , H I-L I M IT S A FE TY (1 20 V ) 8394 9 ALL 5 GROMME T ,.
SERVICING INSTRUCTIONS — DE-LIMING HE A TER TANK 1. Disconn e ct brewer form the electrical suppl y. Turn off the water suppl y and disconne ct water suppl y from the brewer inlet fitting. 2. R emove the top panel to gain acc ess to internal components.
TROUBLESHOOTING SUGGESTIONS If the E-Max T™ goes into the error m o d e as ou tlined belo w, it will likely be necessar y to reset the brewer in order to test individual com ponents.
E-Max T™ TEST PROGRAM 18 Instructions for testing procedures fo r the follow in g system components (using the E-Max T™ Built-In Diagnostic): Electronic Board Softwa re (Firmwa re) Re vision Keypad switches LED’s Inlet valve, Dump (Brew) valve, By Pass Valve Water level probe, Temperature probe A.
E-Max T™ TEST PROGRAM (continued) 19 E. LED Test The display should read “Testing LED’s”: Individual LED’s will be tested i ndividually, beginning with the first on the left, and proceeding thro ugh all six LED’s at one-second intervals. Screen will read “Testing LED’s” during the entire test.
EXPLODED VIEW & PARTS LIST 20.
EXPLODED VIEW & PART S LIST (continued) 21 ITEM P ART # DESCRIPTI ON QTY 1 8783-1 F A UCET , HOT W A TER 1 2 83500 T A NK ASSEM BL Y , 120V 1 3 83480 THERMISTOR , 5-½" 1 4 83949 THERMO, HI -.
WIRING DIAGRAMS (continued) 22.
NOTES 23.
PRINTED IN UNITED STATES OF AMERICA Bloo mf iel d Indu stri es, Inc . Division of Carrier Co mmercial Refrigeration In US and Can ada T elep hone: 775 -689- 5700 Fa x: 888-4 92-2783 Fa x: 800-3 56-5142 () websi te: www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bloomfield 2030 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bloomfield 2030 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bloomfield 2030 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bloomfield 2030 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bloomfield 2030, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bloomfield 2030.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bloomfield 2030. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bloomfield 2030 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.