V enezia Z VE-E3 0S Z VE-E3 6S Z VE-E42S Model number: Serial number: Use, Care, and Installation Guide MAY07.0101 © Zeph yr Corporation. www .zephyronline.
www .zephyronline.com.
T able of Contents 1 SAFET Y NOTICE .............................................. LIST OF MA TERIALS ....................................... INST ALLA TION Ducting Calculation Sheet ............................... Mounting Height and Clearance ......
www .zephyronline.com Im p or tan t s afet y N ot i c e 2 T O RE DUC E T H E R I S K O F F I R E O R E L E C T R IC SH OC K, D O N O T US E T H IS FAN W ITH ANY S O L ID- S T ATE SP E E D C O NTRO L D EV I C E. TO R E DUC E T H E R I S K O F F I R E, E L E C T R I C S H O C K, O R INJ U R Y TO P E R SON S, O B S E RVE T H E F O L LO W I N G: a.
List of Materials 3 1 - Hood 2 - Metallic lters (3 - ZVE-E3 6, E42) 2 - Halogen light bulbs (4 - ZVE-E3 6, E42) 1 - Duct cover assembly (2 pieces) 1 - Hardware bag 1 - Duct cover mounting bracket 1.
www .zephyronline.com 4 Installation - Ductwork Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3 1/ 4” x 10” Rect., straight 1 Ft. x ( ) = Ft. 7” Round, straight 1 Ft. x ( ) = Ft. 3 1/ 4” x 10” Rect. 90 0 elbow 15 Ft .
5 - n o i t a l l a t s n I e c n a r a e l C & t h g i e H g n i t n u o M DUC T ING min. ducted - 32 1/2” min recirc. - 36” max. 51” *m i n . 9 7 " * * ma x. 123" 36" 9 -27/32" mi n . 2 8" - max . 3 6" Minimum mount height between range top to hood bot- tom should be no less than 28".
www .zephyronline.com 6 Installation - Ducting W AR NING F IRE HA ZA RD N EVE R exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option.
7 - n o i t a l l a t s n I s n o i t a c i f i c e p S 6.5" 6" 10.37" 13.87" 2.78" 1.87" 0.5" 3/4" Elec. K.O. Cable Lock All Electrical work must by performed by qualied electrician or person with similar technical know how and backgr ound.
www .zephyronline.com 8 - n o i t a l l a t s n I r e v o C t c u D & d o o H e h t g n i t n u o M 1. Measure from range top to hood bottom (28” min) Level and mark line A. 2. Plum and mark center line. 3. Mark mounting height line B. (10-3/8” from line A) 4.
9 Installation - Ductless Recirculating Ductless recirculating i s intended for applications where an exhaust duct work is not possible to be installed. W hen converted, the hood functions as a "purifying" hood rather than an exhaust hood. Fumes and e xhaust from cooking is drawn and ltered by a set of optional charcoal lters.
www .zephyronline.com 10 F eatures & Controls - T ouc h Controls & F eatures The standard Metal Filters are required to be cleaned frequently and as recommended in order to maintain blo wer eciency .
11 F eatures & Controls - Charcoal Filters Change Indicator Filter Change Reminder (Charcoal, if tted): W hen your hood is installed as a ' Recirculating' (Ductless) unit, it is tted with a set of Charcoal Filters to purify e xhaust and fumes from cooking, then re-circulate the air within the home.
www .zephyronline.com 12 F eatures & Controls - Metal Filters Clean Indicator Filter Clean Reminder (Standard Metal Filters tted): W hether your hood is installed as an Exhaust or Purifying unit, a set of metal lters are tted by the factory .
13 Maintenance - Cleaning Surface Maintenance: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratc h and damage surface. F or heavier soil use liquid degreaser.
www .zephyronline.com 14 Maintenance - Lights Replacing Light Bulbs CA UTI O N: Light bulb becomes extremely hot when turned on. DO NO T touch bulb until switched o and cooled. T ouc hing hot bulbs could cause serious burns. Make sure all power is turned o and bulbs are not hot.
15 T rouble Shooting After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Metal lter is vibrating. 1. The power source is not turned ON.
List of Parts and A ccessories 16 Light Bulb (J D R-E27) Z0B-0011 Metallic Filters (2 pk) Z0F-M042 Metallic Filters (3 pk) Z0F-M043 T elescopic Back Splash 30” Z0S-0013 T elescopic Back Splash 36”.
www.zephyronline.com Warranty One Y ear Service R epair W arranty: F or one year from date of original purchase, we will provide free of charge, service lab or to repair any failed parts or components due to manufacturing defects.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Zephyr ZVE-E30S è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Zephyr ZVE-E30S - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Zephyr ZVE-E30S imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Zephyr ZVE-E30S ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Zephyr ZVE-E30S, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Zephyr ZVE-E30S.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Zephyr ZVE-E30S. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Zephyr ZVE-E30S insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.