Manuale d’uso / di manutenzione del prodotto Range Hood APN-M90AWX del fabbricante Zephyr
Vai alla pagina of 20
ww w .zeph yronline .com Plane APN-M90ABX APN-M90A WX RANGE HOOD - Installation instructions.
ww w .zeph yronline .com HO T TE PER CUISINE - Notice d’utilisation ...P ag. 21 CAMP ANA EXTRACT OR A - Manual de utilización ...P ag. 41 CAPP A ASPIRANTE - istruzioni per l’uso .
C onten ts SAFETY INSTRUC TIONS .................................................................................................. pag . 4 LIST OF MA TERIALS .............................................................................................
ww w .zeph yronline .com IMPORT ANT SAFETY INSTRUC TIONS FOR RESIDENTIAL USE ONL Y READ AND SA VE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORT ANT : Save these Instructions for the Local Electrical Inspec tors use . INST ALLER : Please leave these Instructions with this unit for the owner .
settings. B. Always turn hood ON when c ook ing at high heat or when ambeing foods ( i.e. Cr epes Suzette , Cherries Jubilee, P eppercorn Beef F lambè ). C. Clean ventilating fans fr equently . Grease should not be allow ed to accumulate on fan or lter .
ww w .zeph yronline .com through the ue (chimney) of fuel burning equipment to prev ent back drafting. F ollow the heating equipment manufacturer ’ s guideline and safety standards such as those.
(1+1) M4 (12) 1/4" Duct Covers Cont rol Electrical Junction Box Duct Cover Bracket Glass Light Bulbs Decorative Mesh F ilters Range Hood Body List of Materials - 7 -.
ww w .zeph yronline .com Duc ting Calcula tion Sheet Maximum Duct Length: F or satisfac tory air mov ement, the total duct length should not exceed 100 equivalent f eet.
Hood Speci cations front of hood side of hood top of hood - 9 -.
ww w .zeph yronline .com Installation - In ternal Blow er The follo wing instruc tions are for installing the internal blo wer . CA UTION: T o reduce the risk of re and electric shock, install this range - hood only with internal blow er models MT -017 provided with the kit cod CBI-600A.
6. Attach the 6 pin male molex connector from blo wer wire to the 6 pin f emale molex connec tor located inside the blower housing . See Fig .6 7. Install blower and blow er plate into blo wer housing by f ollowing the rev erse instruc tions from step 2.
ww w .zeph yronline .com The follo wing instruc tions are for pr eparing the hood for use with an e x- ternal or in-line blow ers models CBE-1000 or PBN-1000A. CA UTION: T o reduce the risk of re and electric shock, install this rangehood only with r emote blow ers ra ted maximum 6.
6. Inser t the 6 pin female molex connector into the junction box. See F ig. 6A. Secure r emote blower junction box to top of blo wer housing using (2) screws . S ee F ig. 6B 7. F eed remote blo wer wir e harness through r emote blower junction box c ov er and Connect the wires with those inside the junction box.
ww w .zeph yronline .com W ARNING FIRE HA ZARD NEVER exhaust air or terminate duct work into spaces between walls , crawl spaces, c eiling, attics or garages . All exhaust must be ducted to the outside, unless using the r ecirculating op- tion. Use single wall rigid Metal ductwork only .
Installation - Moun ting the R ange Hood MOUNTING HEIGHTS The range hood must be installed at a minimum eight of 24 inches (71cm) from the cooking sur face. If a connecting duct work composed of two par ts is used, the upper part must be placed outside the low er par t.
ww w .zeph yronline .com GENERAL • Carefully r ead the following impor tant information r egarding installation safety and maintenance . Keep this information book let accessible f or fur ther consultations. POWER SUPPL Y CONNECTION F or connec tion to the po wer supply ref er to the follo wing: 1.
MOUNTING THE DUCT CO VER 1. Install the elec trical wiring and test hood f or functions prior to installing the duc t co vers . 2. If using hood in air recirculating mode make sure to install the air diverter plate prior to mounting the duct covers . See the manual included with the recir culating k it f or more instructions.
ww w .zeph yronline .com Maintencanc e MAINTENANCE • It is recommended to operate the appliance prior t o cooking. It is recommended to leav e the appliance in operation f or 5 minutes after cooking is completed in order to c ompletely eliminate cooking vapors and odors.
List of P ar ts and A cc essories DESCRIPTION HOOD P ART# REPLA CEMENT P ARTS Light Bulb GU4, 20W (each) APN Z0B0030 OPTIONAL A CCESSORIES Recirculating Kit APN ZRC-00PN Replacement Char coal F ilt ers APN Z0F-00A C Duct Cover Extension APN Z1C-00PN T o order parts, visit us online at http://store .
ww w .zeph yronline .com - 20 -.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Zephyr Range Hood APN-M90AWX è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Zephyr Range Hood APN-M90AWX - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Zephyr Range Hood APN-M90AWX imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Zephyr Range Hood APN-M90AWX ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Zephyr Range Hood APN-M90AWX, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Zephyr Range Hood APN-M90AWX.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Zephyr Range Hood APN-M90AWX. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Zephyr Range Hood APN-M90AWX insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.