Manuale d’uso / di manutenzione del prodotto CTP-E 60SX del fabbricante Zephyr
Vai alla pagina of 23
T rapeze C TP-E 4 8SX C TP-E54SX C TP-E 6 0SX Model number: Serial number: U s e , C a r e , a n d I n s ta l la tion G u id e MAY07.0101 © Zep h yr Corpo ration.
www .zephyronline.com.
T able of Contents 1 SAFET Y NO TICE .............................................. LIST OF MA TERIALS ....................................... INST ALLA TION Ducting Calculation Sheet ............................... Mounting Height and Clearance .....
www .zephyronline.com Im p or tan t s afety N o t i c e 2 TO R ED U C E T H E R I S K O F F I R E O R E L E C TR IC SH OC K, D O N O T USE T H IS FAN W ITH ANY S O L I D-S T ATE SP E E D CONTRO L DE V I C E . TO R E DUC E T H E R I S K O F F I R E, E L E C T R IC SH O C K, O R I NJ U R Y TO P E R S ON S, O B S E RVE T H E F O L LO W I N G: a.
Li s t o f M a t e r ia l s 3 MODEL: CTP-ExxS 1 - Hood 2 - Bae Filters 4 - G U-10, 120V 50 W , halogen bulbs 2 - Utensil Rails 2 - T elescopic Duct Covers 4 - T elescopic Rods Sets 4 - Angle Bra c .
www .zephyronline.com 4 I n s t a lla t io n - Duct wo rk C a lcula t io n S h e e t Duct pieces To t a l Equivalent number length x used = 31 / 4 ”x1 0 ” Rect., straight 1 F t . x ( ) = Ft. 7” Round, straight 1 Ft. x ( ) = Ft. 31 / 4 ”x1 0 ” Rect.
5 I n s ta lla tion - M o unt i ng H e i ght & C l e a ra nc e DUC T I N G 9" 36" Min 98"-Max 124” Min 28"-Max 36" Min 34"-Max 52" Minimum mount height between range top to hood b ot- tom should be no less than 28".
www .zephyronline.com 6 I n s t a lla t io n - Du ct ing WARNING FIRE HAZARD N EV E R exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside. Use single wall rigid Metal ductwork onl y .
15 3/4” 9“ “ 6 “ 9 ” 2 5 x a M - “ 4 3 n i M 26 5/8” 32” 48” , 54” , 59 1/8” Min 21” - Max 40” 12 1/8” 7 - n o i t a l l a t s n I s n o i t a c i f i c e p S 2” 2” 7/6.
www .zephyronline.com I n s t a lla t io n - In t er n a l B l ow er 8 The internal blower kit consists of the blower and capacitor box with wiring. A TTE NTI O N The following are intructions for installing internal blower model CB I-600. F or instructions on preparing for external blower model CB E-1000 please turn to page “10” .
I n s t a lla t io n - In t er n a l B l ow er 9 6. Attach junction box to internal ange using provided 1/2” self tapping screws and 4mm internal diameter washers. 7 . Att ac h grounding wires from junction box and motor to grounding screw as shown.
www .zephyronline.com 10 I n s t a lla t io n - P re p a rin g H o o d fo r E xt e rn a l B lo we r The external blower kit consists of an 8” collar , external ange and external blower wiring box.
11 In s ta l l at i o n - M o unt i ng t he H o o d All Electrical work must by performed by qualied electrician or person with similar technical know how and bac kgr ound. F or personal saf ety , remove house fuse or open circuit breaker before beginning installation.
12 I n s t a lla t io n - M o u n ti n g th e H o o d 1. Mount motor housing to the range hood b ody using (10) 1/2” self tapping screws. 2. Determine height of hood, measure and select either 27 3/8” or 35 3/8” angle brac kets and attach (4) of them to the motor housing using (8) 1/2” self tapping screws (2) for each angle brac ket.
13 I n s t a lla t io n - M o u n ti n g th e H o o d 5. Lift assembled unit and atta ch all (4) angle bra ckets to ceiling bra cket. Make sure the tabs on eac h angle bra ckets are facing the outside. T he angle brackets will t between the slots on the ceiling bra cket.
I n s t a lla t io n - M o u n ti n g th e H o o d 14 Utensil Rail Installation 1. A ttach utensil rail to long side of hood canopy . A small hole has been pre-drilled into the canopy to provide a starting point to attach the rst utensil rail post.
18 F ea t u r e s & C on t r ol s - T ou c h C on t r ol s & F e a t u r es The standard Bae Filters are required to be cleaned frequently and as recommended in order to maintain blower eciency .
16 Filter Clean Reminder (Standard Bae Filters tted): A set of bae lters are tted by the factory . These Bae Filters are intended to lter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean.
www .zephyronline.com 17 M a int e n a nce - C le aning Surface Maintenance: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface.
18 Ma i n t e n an c e - Lights R eplacing Light Bulbs: CA UTION: Light bulbs become extremely hot when turned on. DO NO T touch bulbs until switc hed o and cooled. T ouching hot bulbs may cause serious burns. Make sure all power is turned o and bulbs are not hot.
www .zephyronline.com T r ou b le S h oot in g 19 After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Filter is vibrating.
20 www .zephyronline.com Halogen Bulb G U-10, 120V, 50W Z0B-0020 Internal Blower, 600 cfm CBI-600 External Blower, 1000 cfm CBE-1000 Duct Cover Extension Kit Z1C-00TP List of Parts and Accessories Par.
www.zephyronline.com Warranty One Y ear Service Repair W arr anty: F or one year from date of original purchase, we will provide free of charge, service labor to repair any failed parts or components due to manufacturing defects.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Zephyr CTP-E 60SX è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Zephyr CTP-E 60SX - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Zephyr CTP-E 60SX imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Zephyr CTP-E 60SX ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Zephyr CTP-E 60SX, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Zephyr CTP-E 60SX.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Zephyr CTP-E 60SX. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Zephyr CTP-E 60SX insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.