ww w .zephyr online.com T ilt A TI-M90ASX A TI-M90ABX RANGE HOOD - Installation instructions.
ww w .zephyr online.com HO T TE PER CUISINE - Notice d’utilisation ...P ag. 23 CAMP ANA EXTRACT ORA - Manual de utilización ...Pag. 45 CAPP A ASPIRANTE - istruzioni per l’uso .
C ontents SAFETY INSTRUCTIONS .................................................................................................. pag. 4 LIST OF MA TERIALS ................................................................................................
ww w .zephyr online.com IMPORT ANT SAFETY INSTRUC TIONS FOR RESIDENTIAL USE ONL Y READ AND SA VE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORT ANT : Save these Instructions for the Local Electrical Inspectors use. INST ALLER : Please leave these Instructions with this unit for the owner .
settings. B. Always turn hood ON when cooking at high heat or when ambeing foods ( i.e. Crepes Suz ette, Cherries Jubilee, P eppercorn Beef F lambè ). C. Clean ventilating fans frequently . Grease should not be allowed to accumulate on fan or lter .
ww w .zephyr online.com through the ue (chimney) of fuel burning equipment to prevent back drafting . F ollow the heating equipment manufacturer ’ s guideline and safety standards such as those .
List of Materials Electrical Junction Box T op Cover F ront Panel Decorative Mesh Filt ers Cont rol Light Bulbs TYPE DESCRIPTION N° A M4 1 + 1 B 1/8" x 1/4" 12 C 1/8" x 2/4" 4 D 1.
ww w .zephyr online.com Duc ting Calcula tion Sheet Maximum Duct Length: F or satisfac tory air movement, the total duct length should not exceed 100 equivalent f eet.
Hood Speci cations front of hood side of hood top of hood - 9 -.
ww w .zephyr online.com NO TE! T he device in this v ersion (with internal suction motor) is equipped for rear discharge of e xhaust air . How ever , if required, it is possible to ha ve the exhaust air discharged fr om the top.
Installation - In ternal Blow er 6. Remove the 6” round metal knockout pla- te from the blow er plate by using a at head screwdriv er . See. F ig.4 7. Remove the (10 ) scr ews securing the blo- wer plate to the blo wer housing and remo- ve blow er plate.
ww w .zephyr online.com Installation - In ternal Blow er 13. Secure Green/Y ellow ground wire connected to the cable to the provided capacit or to blower plate. (type A) F ig. 11 14. Attach the 6 pin male molex connector from blower wir e to the 6 pin female molex connector located inside the blower housing .
Installation - External & In-Line Blow er Prepar ation NO TE! T he device in this v ersion (with external motor) is equipped for rear discharge of e xhaust air . How ever , if required, it is possible to ha ve the exhaust air discharged fr om the top.
ww w .zephyr online.com Installation - External & In-Line Blow er Prepar ation 5. Close the front panel while holding it by its external sides until it shuts. 6. Remove the metal motor plat e by striking it with the aid of a slotted screw driver .
Note : Carry out the power supplly con- nection in accordance with the national electric code, ANSI/NFP A 70-1999. Note1 : A cable lock (not included) may be required b y local codes. Please review lo- cal codes for mor e information. 12. Attach 6 pin male molex connectors to 6 pin female molex connectors inside blo- wer housing.
ww w .zephyr online.com W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, cra wl spaces, ceiling , attics or garages. All exhaust must be ducted to the outside, unless using the recir culating op - tion. Use single wall rigid Metal ductwork only .
Installation - Moun ting the R ange Hood MOUNTING HEIGHTS The range hood must be installed at a minimum height of 22 inches (56 cm) from the cooking sur face. If a connecting duct work composed of two parts is used, the upper par t must be placed outside the lower part.
ww w .zephyr online.com W ARNING: In order to facilitate their c onnec tion, make sure that the pow er supply conduits are not obstructed by the hood . 3. When the hood has been adjusted tighten the screws t o secure the hood in place. 4. Once the adjustment has been completed , x the hood de nitely using another (2 type D) screws.
Installation - P o wer Supply C onnection GENERAL • Carefully r ead the following important information regarding installation safety and maintenance . Keep this information booklet accessible for further consultations. POWER SUPPL Y CONNECTION F or connection to the power supply ref er to the following: 1.
ww w .zephyr online.com Maintencanc e MAINTENANCE • It is recommended to operate the appliance prior to c ook ing. It is recommended to leave the applianc e in operation for 5 minutes after cooking is completed in order to complet ely eliminate cooking vapors and odors.
List of P ar ts and Acc essories DESCRIPTION HOOD P ART# REPLACEMENT P ARTS Light Bulb GU5, 20W (each) A TI Z0B0031 OPTIONAL AC CESSORIES Recirculating Kit A TI ZRC-00HZ Replacement Charc oal Filters .
3LIK0505.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Zephyr ATI-M90ASX è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Zephyr ATI-M90ASX - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Zephyr ATI-M90ASX imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Zephyr ATI-M90ASX ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Zephyr ATI-M90ASX, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Zephyr ATI-M90ASX.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Zephyr ATI-M90ASX. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Zephyr ATI-M90ASX insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.