Z e n i t h ® P u m p s I n s t a l l a t i o n , C a r e a n d M a i n t e n a n c e Z e n i t h P o l y m e r E x t r u s i o n G e a r Pu m p s P E P - I I S e r i e s G e a r P u m p s.
Zenith ® Pumps 2 Thoroughly read and understand this entire manual before installation and operation of pump. Benefits Specifications Capacities: 0.16 to 750 cc/rev . Operating Speed: 10 - 90 rpm on most extrusion processes depending upon process parameters Differential Pressure: Up to 5,000 psi (345 bar) Body Pressure: 10,000 psi (690 bar).
Zenith ® Pumps and The Extrusion Pr ocess Design Zenith Pumps can handle all your extrusion pumping applications including additive injection for on-line compounding of tackifiers, colorants, stabilizers, etc.
PEP-II Pump 0.16-3 cc/r ev ITEM QTY P ART MA TERIAL 1 1 FRONT PLA TE TOOL STEEL 2 1 CENTER PLA TE TOOL STEEL 3 1 REAR PLA TE TOOL STEEL 4 1 DRIVE SHAFT TOOL STEEL 5 1 ARBOR TOOL STEEL 6 2 METERING GEA.
ITEM QTY P ART MA TERIAL 1 1 DRIVING GEAR SHAFT TOOL STEEL 2 1 DRIVEN GEAR SHAFT TOOL STEEL 3 1 CENTER PLA TE TOOL STEEL 4 2 COVER PLA TE 4140 6 2 BEARING TOOL STEEL 7 2 BEARING TOOL STEEL 14 2 SEAL P.
Operation 6 Installation Polymer enters the PEP-II pump on the suction side where shaft r otation exposes gear tooth volumes between the gear teeth. Polymer fills these spaces and is transported to the discharge side where the gear teeth mesh together , decreasing the gear tooth volumes and displacing the polymer .
Cleaning, Inspection, Repair and Service 7 Disassembly After removal fr om the system, the assem- bled pump can be cleaned by placing it in a suitable furnace (i.e. vacuum oven, fluidized bed, etc.) and slowly increasing the temperature to 800-850° F in no less than two hours.
Disassembly continued 8 D-Bearing Orientation Schematic plate and set aside in a safe place to pre- vent damage. At this point, make certain to note the orientation of the groove on the rear of each bearing with r espect to the inlet port.
Reassembly 9 These instructions should be thoroughly read and understood befor e starting reassembly . General instructions that should be observed to ensure corr ect reassembly of the pump are as follows: • Using a solvent such as trichloroethane or chlor oethene Nu, clean all parts that are to be used in the reassembled pump.
Size (UNC Recommended Alloy Steel) T orque (in-lbs) 1/2-13 922 9/16-12 1,331 5/8-11 1,836 3/4-10 3,257 7/8-9 5,800 1-8 8,000 1 1/8-7 12,000 10 Reassembly continued Bolt T or que Size (UNC Recommended .
11 T r oubleshooting Par ts Replacement When ordering r eplacement parts, please be sure to include the following information: 1) Pump model number 2) Part number (12-digit) and description 3) Quantity 4) Shipping instructions Order parts from your local Zenith r epresentative or dir ect from Zenith.
F AILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELA TED ITEMS CAN CAUSE DEA TH, PERSONAL INJURY AND PROPERTY DAMAGE.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Zenith Pumps è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Zenith Pumps - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Zenith Pumps imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Zenith Pumps ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Zenith Pumps, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Zenith Pumps.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Zenith Pumps. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Zenith Pumps insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.