TECHNICAL GUIDE SPLIT -SYSTEM AIR CONDITIONERS 10 SEER MODELS: H*RA018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) H*RA036 THRU 090 (3 THRU 7.5 NOMINAL TONS, 3 PH) MODELS: 018 - 060 (1 PH & 3 PH) MODELS: 076 - 090 (3 PH) Due to con tinuous p roduct improve ment, speci fica- tions are subj ect to change with out notice.
036-21121-002 Rev. A (0602 ) 2 Unitary Products Group 1. Rat ed in accordance with ARI S tandard 1 10, utilization range “A”. 2. Dua l element fuses or HACR circuit br eaker . 3. All scrolls listed with a sup erscript “B” are Bristol scrolls. All sc rolls listed w ith a superscript “C” are Copeland scrolls.
036-21121-002 Rev. A (0602) Unitary Products Group 3 COOLING CAP ACITY - Wi th Air Handler Coils UNIT MODEL AIR HANDLER COIL 1 MODEL COOLING MODEL ELECTRIC 2 HEA T KW W RA TED CFM NET MBH SEER W/O TXV SEER + TXV 3 EER TOT AL SENS. 1 PH 10 SEER AC WITH N1AH / G2FD H1RA018S06 N1AHB0806 2,5,8,10 17 G2FD024S17 650 19.
036-21121-002 Rev. A (0602 ) 4 Unitary Products Group COOLING CAP ACITY - Up flow , Downflow , & Horizont al Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (MIN.-MAX.) W RA TED CFM NET MBH SEER + TXV W/O TDR SEER + TXV 1 + TDR* EER TOT AL SE NS .
036-21121-002 Rev. A (0602) Unitary Products Group 5 * Requires a 2FD Blower T ime Delay unless a standa rd furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up. *** This coil is for upflow application only . H1RA036S25,46 1050 1350 17,21 G1F A036S17,21 1200 33.
036-21121-002 Rev. A (0602 ) 6 Unitary Products Group NOTES: 1. For condensing unit only . Does not include e ffect of evaporator motor power or heat. 2. Performance based on 1 5° superheat and 1 5° sub-cooling at condensing unit. a. Increase capacity 1% for each 2° increase in sub-cooling.
036-21121-002 Rev. A (0602) Unitary Products Group 7 ACCESSORIES* Refer to Price Manual for specific model numbers. Hard St art Kit - Provides increased starting torque for areas with low voltage. Compressor Blanket - Designed to further reduce the nor- mal compressor operating sound.
036-21121-002 Rev. A (0602 ) 8 Unitary Products Group TYPICAL FIELD WIRING - 1 Phase Application TYPICAL FIELD WIRING - 3 Phase Application ALL FIELD WIRING T O BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING 208/230-1-60 230-1-50 CONT ACTOR TERMINALS COIL GND.
036-21121-002 Rev. A (0602) Unitary Products Group 9 Multipliers for determining the performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21121-002 Rev. A (0602 ) 10 Unitary Products Group Multipliers for determining the p erformance with other indoor sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21121-002 Rev. A (0602) Unitary Products Group 11 Multipliers for determining th e performance with other indoo r sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21121-002 Rev. A (0602 ) 12 Unitary Products Group Multipliers for determining th e performance with other indoo r sections. 1 Phase 3 Phase COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO .
036-21121-002 Rev. A (0602) Unitary Products Group 13 Multipliers for determining th e performance with other indoo r sections. 1 Phase 3 Phase COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21121-002 Rev. A (0602 ) 14 Unitary Products Group Multipliers for determining th e performance with other indoo r sections. 1 Phase 3 Phase COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO .
036-21121-002 Rev. A (0602) Unitary Products Group 15 Multipliers for determining th e performance with other indoo r sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21121-002 Rev. A (0602 ) 16 Unitary Products Group Multipliers for determining th e performance with other indoo r sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21121-002 Rev. A (0602) Unitary Products Group 17 Multipliers for determining th e performance with other indoo r sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21121-002 Rev. A (0602 ) 18 Unitary Products Group Multipliers for determining th e performance with other indoo r sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21121-002 Rev. A (0602) Unitary Products Group 19 MA TCHING INDOOR COMPONENTS G1UA 1/2 CASED UPFLOW G1HD HORIZONT AL DUCT G2FD* MUL TI-POSITION (UPFLOW , HORIZONT AL AND DOWNFLOW) * Available with factory installed horizontal drain pan. ADD-ON COILS - FOR FURNACE APPLICA TIONS G1NA UNCASED UPFLOW G1F A FULL CASED UPFLOW G2FD090 is upflow only .
Subject to change without notice. Printed in U .S.A. 036-21121-002 Rev. A (0602) Copyright © by York International Corp. 2002. All right s reserved. Supersedes: 036-21 121-001 Rev .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il York THRU H*RA018 THRU 060 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del York THRU H*RA018 THRU 060 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso York THRU H*RA018 THRU 060 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul York THRU H*RA018 THRU 060 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il York THRU H*RA018 THRU 060, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del York THRU H*RA018 THRU 060.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il York THRU H*RA018 THRU 060. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo York THRU H*RA018 THRU 060 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.