Manuale d’uso / di manutenzione del prodotto TCGF24 del fabbricante York
Vai alla pagina of 22
TECHNICAL GUIDE SPLIT -SYSTEM A IR CONDITIONERS 14.5 SEER – R-410A MODELS: TCGF24 TH RU 60 (2 THRU 5 NOMINA L TONS, 1 PHASE) Due to continuous produc t impr ovement, specifications are subject to change without notice. V isit us on th e web at www .
413432-YTG-A-0608 2 Johnson Controls Unitary Products All dimensions are in inches. They are subject to cha nge without notice. Ce rtif ied dimensio ns will be provide d upon request.
413432-YTG-A-0608 Johnson Controls Unitary Produ cts 3 Additional R-410A Ch arge / Orifice Size for V arious Matched Systems Outdoor Unit TCGF24S41S1 TCGF30S41S1 TCGF36S41S1 TCGF42S41S1 TCGF48S41S1 TC.
413432-YTG-A-0608 4 Johnson Controls Unitary Products PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refr igerant for th e condenser , the smallest evaporator and 15 feet of inter- connecting line tubing.
413432-YTG-A-0608 Johnson Controls Unitary Produ cts 5 COOLING CAP ACITY - Wi th Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL W RA TED CFM NET MBH SEER EER TOT AL SENS. 14.5 SEER AC WITH MA TCGF24S41S1 MA08B 17 FC/MC24B 800 24.8 17.
413432-YTG-A-0608 6 Johnson Controls Unitary Products — = Not applicable. 14.5 SEER AC WITH MV - V ARIABLE SPEED (Contimued) TCGF42S41S1 MV16C 21 FC/MC43C 1400 41.0 30 .8 15.00 12.75 MV16C 21 FC/MC48C 1400 41.5 31 .2 15.50 13.00 MV20D 24 FC/MC48D 1400 42.
413432-YTG-A-0608 Johnson Controls Unitary Produ cts 7 COOLING CAP ACITY - Up flow , Downflow & Horizont al Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (Min.-max.) W RA TED CFM NET MBH SEER 1 EER TOT AL SENS. TCGF24S41S1 600 - 1000 14,17 FC/MC/PC24 800 24 .
413432-YTG-A-0608 8 Johnson Controls Unitary Products COOLING CAP ACITY - With V ariable Spe ed Furnaces UNIT MODEL V ARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RA TED CFM Net MBH SEER EER TOT AL SENS. 14.5 SEER AC WITH V ARIABLE SPEED FURNACES 2 TCGF24S41S1 PV8*A12 FC/MC/PC24A 14 750 24.
413432-YTG-A-0608 Johnson Controls Unitary Produ cts 9 TCGF30S41S1 PV8*A12 FC/MC/PC36A 14 1000 29.4 21.2 15.25 13.00 PV8*B16 FC/MC/PC36B 17 1050 29.8 22.0 15.75 13.25 PV8*C16 FC/MC/PC36C 21 1000 29.6 21.4 15.75 1 3.25 PV8*C20 FC/MC/PC36C 21 1 100 30.2 22.
413432-YTG-A-0608 10 Johnson Controls Unitary Products TCGF36S41S1 PV8*C20 FC/MC/PC36C 21 1200 34.0 24.6 15.25 12 .75 PV9*A12 FC/MC/PC36A 14 1200 33.6 24.2 14.25 12.00 P(C,V)9*B12 FC/MC/PC36B 17 1200 33.8 24.4 14.75 12 .25 P(C,V)9*C16 FC/MC/PC36C 21 1200 34 .
413432-YTG-A-0608 Johnson Controls Unitary Produ cts 11 TCGF42S41S1 P(C,V)9*C20 FC/MC/PC60C 21 1350 41 .5 31.2 15.25 1 2.75 P(C,V)9*D20 FC/MC/PC60D 24 1350 41 .5 31.2 15.50 1 3.00 PV8*C16 HC42C 21 1400 41 .0 30.6 15.00 12.50 PV8*C20 HC42C 21 1400 41 .
413432-YTG-A-0608 12 Johnson Controls Unitary Products ACCESSORIES Refer to Price Manual for specific model numbers. HARD ST ART KIT - Required when using TXV i ndoor coil. Also, provides increased starting torque for a reas with low voltage. OFF CYCLE TIMER DELA Y - Provides a 5-minute off cycle to prevent rapid recycling of the compressor .
413432-YTG-A-0608 Johnson Controls Unitary Produ cts 13 Multipliers for determining the performance with other indoor sections . For dry bulb temperatures dif ferent than those listed (betwee n 73-87 .
413432-YTG-A-0608 14 Johnson Controls Unitary Products Air Handler Coil T .C. S.C. KW - FC/MC/PC24 1.02 1.04 1.02 - FC/MC/PC30 1.02 1.04 1.02 - FC/MC/PC35 1.02 1.06 1.02 - FC/MC/PC36 1.02 1.06 1.02 - FC/MC/PC37 1.04 1.08 1.02 - FC/MC/PC43 1.03 1.08 1.
413432-YTG-A-0608 Johnson Controls Unitary Produ cts 15 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between.
413432-YTG-A-0608 16 Johnson Controls Unitary Products Air Handler Coil T .C. S.C. KW - FC/MC/PC30 0.97 0.95 1.00 - FC/MC/PC32 0.98 0.98 1.00 - FC/MC/PC35 0.98 0.98 1.00 - FC/MC/PC36 0.98 0.97 1.00 - FC/MC/PC37 1.00 1.00 1.00 - FC/MC/PC42 0.94 0.95 1.
413432-YTG-A-0608 Johnson Controls Unitary Produ cts 17 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between.
413432-YTG-A-0608 18 Johnson Controls Unitary Products Air Handler Coil T .C. S.C. KW - FC/MC/PC35 0.98 0.98 1.00 - FC/MC/PC36 0.97 0.96 1.00 - FC/MC/PC37 1.00 1.00 1.00 - FC/MC/PC48 1.01 1.01 1.00 - FC/MC/PC60 1.01 1.02 1.00 - FC/MC62 1.01 1.02 1.00 - UC60 0.
413432-YTG-A-0608 Johnson Controls Unitary Produ cts 19 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between.
413432-YTG-A-0608 20 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those liste d (bet ween.
413432-YTG-A-0608 Johnson Controls Unitary Produ cts 21 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between.
Subject to change without notice. Printe d in U.S.A. 413432-YTG-A-0608 Copyright © 2008 by Johnson Controls, Inc. All rights reserved. Supersedes: Nothing Johnson Controls Unitary Product s 5005 Y or.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il York TCGF24 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del York TCGF24 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso York TCGF24 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul York TCGF24 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il York TCGF24, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del York TCGF24.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il York TCGF24. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo York TCGF24 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.