GENERAL These completely assembled indoor units include a well- insulated cabinet, a copper tube/aluminum fin coil, throw - away filters, a centrifugal blower , a blower motor , an adjust - able V -belt drive, a blower motor contactor and a small holding charge of an inert gas.
035-09651-001-A-0304 2 Unitary Products Group T ABLE OF CONTENTS GENERAL ............................................................................. 1 REFERENCE ............................................................................. 1 INSPECTION .
rate request for inspection by the carrier's agent should be made in writing. LIMIT ATIONS These units must be installed in accordance with all national and local safety codes. If no local codes apply , installation must conform with the appropriate national codes.
035-09651-001-A-0304 4 Unitary Products Group FIG . 1 - UNIT SUSPENSION MOUNTING (Horizontal Application) Model Power Supply V oltage V ariation 1 Supply Air CFM Entering Air T emperatures, ° F Cooling - wb Heating - db Min. Max. Min. Max. Min. Max. Min.
WARNING: Do not permit overhanging structures or shrubs to obstruct air discharge. Additional height may be required for snow clearance if winter operation is expected.
Form 035-16650-001 – Supply Air Plenum Form 035-16621-001 – Return Air Grille Form 035-16632-001 – Base The supply air plenum and the return air grille should be used in lieu of ductwork only when a free blow/free return application is practical.
A 7/8" OD drain connection extends through right hand side of cabinet. Refer to Fig. 7 for recommended drain piping. The drain connection is located on the same side of the unit as the refrigerant connections. The line should be insulated where moisture drippage will be objectionable or cause damage to the area.
035-09651-001-A-0304 8 Unitary Products Group FIG . 9 - HOLE LOCA TIONS FOR PRESSURE DROP READINGS FIG . 10 - PRESSURE DROP ACROSS A DRY INDOOR COIL VS. SUPPL Y AIR CFM RPM CFM ESP 2 BHP KW ESP 2 BHP KW ESP 2 BHP KW ESP 2 BHP KW ESP 2 BHP KW F3EH090 (60 Hz) 2400 2700 3000 3300 3600 600 0.
035-09651-001-A-0304 Unitary Products Group 9 Model Accessory S tatic Resistance, IWG BLOWER CFM 2400 2700 3000 3300 3600 F3EH090 Electric Heat 10 KW 0.01 0.01 0.01 0.02 0.02 16 KW 0.01 0.02 0.02 0.03 0.04 26 KW 0.03 0.04 0.05 0.06 0.07 36 KW 0.05 0.07 0.
POWER AND CONTROL WIRING Install electrical wiring in accordance with the latest National Electrical Code (NFP A S tandard No. 70) and/or local regula - tions.
035-09651-001-A-0304 Unitary Products Group 11 FIG .12 - UNIT DIMENSIONS & CLEARANCES (F3EH090 & F4EH120) All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. ACCESSORIES • ELECTRIC HEA TER - Add 14-1/4" to unit height when used.
SECURE OWNER'S APPROV AL: When the system is functioning properly , secure the owner's approval. Show him the location of all disconnect switches and the thermostat.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il York F3EH090 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del York F3EH090 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso York F3EH090 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul York F3EH090 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il York F3EH090, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del York F3EH090.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il York F3EH090. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo York F3EH090 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.