Manuale d’uso / di manutenzione del prodotto D1EG del fabbricante York
Vai alla pagina of 32
036- 21411-002- A-0204 FOR DISTRI BUTION USE ONLY - NOT TO B E USED A T POINT OF RETAIL S ALE TECHNICAL GUIDE SUNLI NE PLUS ™ AIR-COOLED AIR CONDITIONERS D1EG/D1EE036, 0 48, & 060 3, 4, AND 5 NOMINAL TONS 1 1 - 1 1.5 SEER ® FLEXIBLE EASY T O I NST ALL SI NGLE P ACKAGE UNITS.
036-214 11-002- A-0204 2 Unitary Products Group T ABLE OF CONTENTS DESCRIPTIO N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 FACTORY-INSTALLED OPTIONS . . . . .
036-2141 1-002-A-0 204 Unitary Products G roup 3 DESCRIPTION YORK Sunl ine Plus™ uni ts are high eff icien cy , convert ible, single pac kage a ir conditio ners w ith a co mmon cab inet an d a common ro of curb for the 3, 4 and 5 ton s izes. Th e unit s we re design ed for light co mmerc ial and co mmercia l applic ations.
036-214 11-002- A-0204 4 Unitary Products Group volt age term inal stri p. An add itiona l set of pin conne ctors i s also pr ovi ded t o simp lify the f ield i nter fac e of ext erna l con - trols. M ate--n--loc k plug connec tors are us ed whe re line and low vo lta ge wires p as s through in ternal bu lkhea ds.
036-2141 1-002-A-0 204 Unitary Products G roup 5 PROP ANE CONVERSION KIT - Converts a ga s-fired heater from natu ral ga s to pr opane . It co ntain s mai n burn er ori fic es, a pilot orifice and a regulator s pring.
036-214 11-002- A-0204 6 Unitary Products Group Not ARI requi red T ABLE 1: CAP ACITY RA TIN GS - COOLING / ELECTRIC HEA TIN G MODEL ARI RA TINGS 1 NOMINAL ELECTRIC HEA T CAP ACITY 2 (kW) COOLING CAP ACITY 80 / 67-9 5°F SOUND RA T ING 3 (dBel s) MBH SEER 4 EER 5 240V 480V 6 00V DEE036 42.
036-2141 1-002-A-0 204 Unitary Products G roup 7 T ABLE 4: PHYSI CAL DA T A - BASIC UNIT MODE LS DEE /D EG 036 048 060 EV APORA TOR BLOWER Centrif ugal Bl ower (D ia. x Wd. in .) Fan Motor HP (Direct - Drive) Fan Mo tor HP (Belt - Drive) 12 x 10 1/2 1.
036-214 11-002- A-0204 8 Unitary Products Group T ABLE 5: COOLING CAP ACI TIES - 3 TON (DEE / DE G036) AIR ON EV APORA T OR COIL TEMPERA TURE OF AIR ON CONDEN SER COIL 85°F 95°F TOT AL CAP . 1 MBH POWER INPUT 2 kW SENSIBLE CAP ACITY 1 , MB H TO T AL CAP .
036-2141 1-002-A-0 204 Unitary Products G roup 9 T ABLE 6: COOLING CA P ACITIES - 4 TON (DEE / DE G048) AIR ON EV APORA T OR COIL TEMPERA TURE OF AIR ON CONDEN SER COIL 85°F 95°F TOT AL CAP . 1 MBH POWER INPUT 2 kW SENSIBLE CAP ACITY 1 , M BH TOTAL CAP .
036-214 11-002- A-0204 10 Unitary Products Group T ABLE 7: COOLING CAP ACI TIES - 5 TON (DEE / DE G060) AIR ON EV APORA T OR COIL TEMPERA TURE OF AIR ON CONDEN SER COIL 85°F 95°F TOT AL CAP . 1 MBH POWER INPUT 2 kW SENSIBLE CAP ACITY 1 , MB H TO T AL CAP .
036-2141 1-002-A-0 204 Unitary Products G roup 11 T ABLE 8: SUPP L Y AIR B LOWER PE RFORMANCE -DEE/D EG036 W/ BE L T DRIVE & SIDE DUCT 1 2 MODEL DEE/DEG AIR FLOW CFM A V AILABLE EXTERNAL ST A TIC PRES SURE - IWG 3 0.20 0 .30 0.40 0. 50 0 .60 0.70 0.
036-214 11-002- A-0204 12 Unitary Products Group T ABLE 9: SUPP L Y AIR B LOWER PE RFORMANCE -DEE/D EG048 W/ BE L T DRIVE & SIDE DUCT 1 2 MODEL DEE/DEG AIR FLOW CFM A V AILABLE EXTERNAL ST A TIC PRES SURE - IWG 3 0.20 0 .30 0.40 0. 50 0 .60 0.70 0.
036-2141 1-002-A-0 204 Unitary Products G roup 13 T ABLE 10: SUPPL Y AIR BLOWER P ERFORMANCE -DEE/DEG060 W/ B EL T DRIVE & SI DE DUCT 1 2 MODEL DEE/DEG AIR FLOW CFM A V AILABLE EXTERNAL ST A TIC PRES SURE - IWG 3 0.20 0 .30 0.40 0. 50 0 .60 0.70 0.
036-214 11-002- A-0204 14 Unitary Products Group T ABLE 1 1: S UPPL Y AIR BLOWER PE RFORMANCE - D EE/DEG036-060 W / DIRECT DRIVE 1 MODE L DEE/DEG MOTOR SPEED A V AILABLE EXTERNAL ST A TIC PRESSURE - IWG 2 0.
036-2141 1-002-A-0 204 Unitary Products G roup 15 T ABLE 13: MOTOR AND DRIVE DA T A - BE L T -DRIVE BLOWE R MODE L BLOWER RANGE RPM MOTOR 1 ADJUST ABLE MOTOR PULLEY FIXED BLOWER PULLEY BEL T HP RPM FRAM E SIZE SERVICE FA C T O R PITCH DIA. (in.) BOR E (in.
036-214 11-002- A-0204 16 Unitary Products Group T ABLE 15: BASIC UNI T W/ BEL T -DRIVE ELECTRICAL DA T A MODEL DEE/ DEG POW ER SUPPL Y VOL T AGE LIMIT A TIONS 1 C OMPRESSOR CON. FA N MOTO R, FLA SUPPL Y AIR BLOWER MOT OR, FLA MINI MUM CIRCUIT AMP A CITY MAX.
036-2141 1-002-A-0 204 Unitary Products G roup 17 T ABLE 16: ELECTRICAL DA T A COOLING/EL E CTRIC HEA T W/ DIRE CT DRIVE DEE 036 MODEL DEE POWER SUPPL Y HEA TER ACCESSOR Y MODEL NUMBER SUPPL Y AIR BLOWER MOTO R FLA ELECTRIC HEA TERS MINIMU M CIRCUIT AMP ACIT Y MAX FUSE SIZE 1 AMPS MAX.
036-214 11-002- A-0204 18 Unitary Products Group T ABLE 17: ELECTRICAL DA T A COOLING/EL E CTRIC HEA T W/ DIRE CT DRIVE DEE 048 MODEL DEE POWER SUPPL Y HEA TER ACCESSOR Y MODEL NUMBER SUPPL Y AIR BLOWER MOTO R FLA ELECTRIC HEA TERS MINIMU M CIRCUIT AMP ACIT Y MAX FUSE SIZE 1 AMPS MAX.
036-2141 1-002-A-0 204 Unitary Products G roup 19 T ABLE 20: ELECTRICAL DA T A COOLING/EL E CTRIC HEA T W/ DIRE CT DRIVE DEE 060 MODEL DEE POWER SUPPL Y HEA TER ACCESSOR Y MODEL NUMBER SUPPL Y AIR BLOWER MOTO R FLA ELECTRIC HEA TERS MINI MUM CIRCUIT AMP ACI TY MAX.
036-214 11-002- A-0204 20 Unitary Products Group T ABLE 21: ELECTRICAL DA T A COOLING/ELE C TRIC HEA T W/ BEL T DRIVE DEE03 6 & 048 MODEL DEE POWER SUPPL Y HEA TER ACCESSOR Y MODEL NUMBER SUPPL Y AIR BLOWER MOTOR FLA ELECTRIC HEA TERS MINIMUM CIRCUIT AMP ACIT Y MAX.
036-2141 1-002-A-0 204 Unitary Products G roup 21 T ABLE 22: ELECTRICAL DA T A COOLING/EL E CTRIC HEA T W/ BEL T DRIVE DEE060 MODEL DEE POWER SUPPL Y HEA TER ACCESSOR Y MODEL NUMBER SUPPL Y AIR BLOWER MOTO R FLA ELECTRIC HEA TERS MINI MUM CIRCUIT AMP ACI TY MAX.
036-214 11-002- A-0204 22 Unitary Products Group FIGURE 2 - POW ER SUPP L Y , POWER WIRI NG SINGLE PHASE FIGURE 3 - POW ER SUPP L Y , POWER WIRI NG THREE PHASE FIGURE 4 - CONTROL WIRING - COOLING ONL .
036-2141 1-002-A-0 204 Unitary Products G roup 23 FIGURE 7 - CONTROL WIRING - COOLING/HE A TING (ELECTRONIC THERMOST A T) R H R C Y W G R Y 1 W 1 B G A D D J U M P E R T H E R M O S T A T 1 T E R M I .
036-214 11-002- A-0204 24 Unitary Products Group FIGURE 9 - UNI T DIMENSION S DEE 3, 4, & 5 TON DEE UNITS 3-5 T ON T ABLE 23: UTILITIES ENTRY DA T A HOLE KNOCKOUT SIZE (DIA.) USED FOR A 7/8” 1 1. Knockouts in the bottom of the unit can be located by the slice in the insulation.
036-2141 1-002-A-0 204 Unitary Products G roup 25 Note: DEE Mod els and d uctwork are approv ed for zero clearan ce to com bustible materi als wh en equ ipped with el ectric he aters. Note: EG M odels mu st hav e a 1” cleara nce betw een any combus tible ma terial a nd the s upply ai r ductwo rk for a dist ance of 3 fe et from the un it.
036-214 11-002- A-0204 26 Unitary Products Group Duct c overs - unit s are shipped with all ai r duct op ening s cover ed. For side duct applicati ons: • Remove and discard the su pply and retu rn air duct cover s. • Conne ct duct work to duc t flan ges on the rear of the un it.
036-2141 1-002-A-0 204 Unitary Products G roup 27 FIGURE 13 -DET AIL B UNI T DIMENSIONS W ITH DAMPER/R AINHOOD FIGURE 14 -UNIT & CURB APPLICA TION 2 7 - 1 / 2 7 - 1 / 4 2 7 - 1 / 2 1 9 - 1 / 8 " A " 4 4 - 7 / 8 4 - 3 / 8 3 - 1 / 2 8 - 1 / 4 1 0 - 1 / 4 L .
036-214 11-002- A-0204 28 Unitary Products Group FIGURE 15 -ROOF CURB DIME NSIONS DEE & DEG 3, 4, & 5 TON T ABLE 25: UNIT WEIGH TS UNIT UNIT WEIGHT (lbs .
036-2141 1-002-A-0 204 Unitary Products G roup 29 FIGURE 17 -TYPICAL APPLICA TIONS FIGURE 18 -TYPICAL ROOF TOP INST ALLA TION.
036-214 11-002- A-0204 30 Unitary Products Group MECHANICAL SP ECIFICA TIONS GENERAL DESC RIPTION Units sh all be Hig h Effici ency fact ory- assemb led, singl e pack- aged, (DUS Electric Cooling/Gas Hea t, DHC Electric Cooling/ Option al Elect ric Heat), d esigned fo r out door mou nted inst al- lation.
036-2141 1-002-A-0 204 Unitary Products G roup 31 a. Balance -port th ermost atic exp ansion valve with indepen dent c ircuit fee d system . b. Filter dri er/strai ner to elim inate an y moistu re or for- eign ma tter .
Subject to change without notic e. Printed i n U.S.A. 036-214 11-002 -A-0204 Copyri ght © 2004 by Uni tary Prod ucts Gro up. All rights res erved. Supersedes : 036 -21411-001 -A-0502 Unit ary 5005 Norma n Product s Y ork O K Group Drive 73069 OPTIONAL OUTDOOR AIR (Shall be made availabl e by e ither/or): 1.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il York D1EG è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del York D1EG - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso York D1EG imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul York D1EG ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il York D1EG, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del York D1EG.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il York D1EG. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo York D1EG insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.