TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT -SYSTEM COOLING & HEA T PUMPS MODELS: AHP18 THRU 60 Due to continuous prod uc t improv e m en t, specifications are subject to change with ou t notice. Visit us on the web at www .york.com Additional rati ng information ca n be found at www .
255029-YTG-M-06 10 2 Johnson Controls Unitary Products DIMENSIONS 10-3/8” F CIRCUIT BREAKER P ANEL BOTTOM INLET DIMENSIONS DRAIN P AN CONNECTIONS FOR HORIZONT AL APPLICATIONS J BLOWER COMP ARTMENT R.
255029-YTG-M-0610 Johnson Controls Unitary Products 3 COIL TECHNICAL DA T A Models Application Refrig. Conn. T ypes Face Area (Sq. Ft.) Rows Deep Fin Per In. Coil Size T ube Geometry T ube Dia. Fin Ty p e TXV AHP18B3XH21 Cooling / Heat Pump Sweat 3.40 2 14 (2) 14 x 17.
255029-YTG-M-06 10 4 Johnson Controls Unitary Products ACCESSORIES Refer to Price Manual for specific model numbers. TXV Kit s - TXV kits are available for “Flex-coil” applications and converting R22 to R410A or as a service replacement. All kits are bolt-on and require no brazing to install.
255029-YTG-M-0610 Johnson Controls Unitary Products 5 All air handler units are UL Listed up to 0.50" w .c. external st atic pressure, including air filter , wet coil, and largest KW s ize heater , unless otherwise noted. AIR FLOW DA T A - 60 Hz MODELS Models Blower Motor Speed 230 V olt CFM 1 @ External St atic Pressure - IWC 0.
255029-YTG-M-06 10 6 Johnson Controls Unitary Products PHYSICAL & ELECTRICAL DA T A Models AHP18B**H21 AHP24B**H21 AHP30B**H21 AHP36C**H21 Blower - Diameter x Width 9 x 6 10 x 9 10 x 9 10 x 10 Motor HP 1/3 HP 1/4 HP 1/2 HP 3/4 HP Nominal RPM 1075 1075 1075 1075 V oltage 230 Amps F ull Load (230) 1.
255029-YTG-M-0610 Johnson Controls Unitary Products 7 * May be 0 (no breaker) or 1 (with breaker). ELECTRICAL DA T A - 208/230-1-60 Models Heater Models* Max. Static Min. Speed Ta p T otal Heat 1 kW St ag ing kW MBH W1 Only W2 Only W1 + W2 208V 240V 208V 240V 20 8V 240V 208V 240V 2 08V 240V AHP18B**H21 4HK*6500206 0.
255029-YTG-M-06 10 8 Johnson Controls Unitary Products * May be 0 (no breaker) or 1 (with breaker). ELECTRICAL DA T A (FOR SI NGLE SOURCE POWER SUPPL Y) - COPPER WIRE 208/230-1-60 Models Heater Models* Heater Amps 240V Field Wiring Min. Circuit Ampacity Max.
255029-YTG-M-0610 Johnson Controls Unitary Products 9 ELECTRICAL DA T A (FOR MUL TI SOURCE PO WE R SUPPL Y) - COPPER WIRE 208/230-1-60 Models Heater Models Min.
255029-YTG-M-06 10 10 Johnson Controls Unitary Products 2. Heaters are 3 Phase. COOLING MODELS W ITH ELECTRIC HEA T WI RING * Optional dehumidification humidistat switch contacts open on humidity rise.
255029-YTG-M-0610 Johnson Controls Unitary Products 11 * Optional dehumidification humidistat switch contacts open on rise. Notes: 1. “Y” T erminal on Air Handler Contr ol Board must be connected for full CFM and applications r equiring 60 second blower off del ay for SEER enhancement.
Subject to change without notice. Published in U .S.A. 255029-YTG-M-0610 Copyright © 2010 by Johnson Controls, Inc. All ri ghts reserved. Supersedes: 255029-YTG-L-0708 Johnson Controls Unitary Produc.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il York AHP18 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del York AHP18 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso York AHP18 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul York AHP18 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il York AHP18, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del York AHP18.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il York AHP18. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo York AHP18 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.