279104-YTG-B-0307 FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TECHNICAL GUIDE SPLIT -SYSTEM HEA T PUMPS 10 SEER – R-22 MODELS: E*RA036 THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) MODELS: 036-048 (3 PH) MODELS: 060, 090 (3 PH) Due to continu ous product improv e ment, specific ations are subjec t to ch an ge without notice.
279104-YTG-B-0307 2 Unitary Products Group All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provid ed upon request.
279104-YTG-B-0307 Unitary Products Group 3 PROCEDURES: 1. Unit factory charge listed on the unit na meplate includes refri gerant for the condenser , the smallest evaporator and 15 feet of intercon- necting line tubing. 2. V er ify the o rifice size and additional charge required for specific evaportor coil in the system using t he above table.
279104-YTG-B-0307 4 Unitary Products Group - = Not applicable COOLING CAP ACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL 1 MODEL COOLING MODEL ELECTRI C 2 HEA T KW W RA TED CFM NET MBH SEER W/O TXV SEER WITH TXV 3 EER TOT AL SENS. 3 PH 10 SEER HP WITH MA / MC / N-AH / G2FD E1RA036S(25,46) MA12BN2,4 10 17 FC/MC35B3X 1250 34.
279104-YTG-B-0307 Unitary Products Group 5 * Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up. COOLING CAP ACITY - Up flow , Downflow , & Horizontal Furnac es and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (MIN.
279104-YTG-B-0307 6 Unitary Products Group COP equals MBH output divided by (t ot al KW input x 3.412). HSPF (Heating Seasonal Performa nce Factor) is the total heatin g output during a normal annual usage perio d for heating divided by the total electric power input during the same period.
279104-YTG-B-0307 Unitary Products Group 7 ACCESSORIES Refer to Price Manual for specific model numbers. S tart A ssist Kit (2SA067*) Blower Time Delay - A vailable to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute a fter cooling thermostat has been satisfied.
279104-YTG-B-0307 8 Unitary Products Group TYPICAL FIELD WIRING - 3 PH (036 - 060) TYPICAL FIELD WIRING - 3 PH (090) THERMOST A T INDOOR UNIT OUTDOOR UNIT LOW VOLT AGE TERMINAL BLOCK IN AIR HANDLER WITH ELECTRIC HEA T 3,4 DEFROST CONTROL 1 FIELD INST ALLED JUMPER GND.
279104-YTG-B-0307 Unitary Products Group 9 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif f erent than those listed (between 73- 87 F), se.
279104-YTG-B-0307 10 Unitary Products Group Multipliers for determining the p erfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif f erent than those listed (between 73 -87 F),.
279104-YTG-B-0307 Unitary Products Group 11 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif f erent than those listed (between 73- 87 F), s.
279104-YTG-B-0307 12 Unitary Products Group Multipliers for determining the p erfo rman ce with other indoor sections. HEA TING PE RFORMANCE DA T A CONDENSING UNIT MODEL NO E1RA036S(25 ,46) EV APORA TOR COIL MODEL NO F2RP/F2FP036 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP .
279104-YTG-B-0307 Unitary Products Group 13 Multipliers for determining the performance with other indoor sections . HEA TING P ERFORMANCE DA T A CONDENSING UNIT MODEL NO E2RA048S(25 ,46) EV APORA TOR COIL MODEL NO F2RP/F2FP048 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP .
279104-YTG-B-0307 14 Unitary Products Group Multipliers for determining the p erfo rman ce with other indoor sections. HEA TING PE RFORMANCE DA T A CONDENSING UNIT MODEL NO E1RA060S(25 ,46) EV APORA TOR COIL MODEL NO G2FD060(S,H)24 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP .
279104-YTG-B-0307 Unitary Products Group 15 NOTES.
Subject to change without notice. Printed in U.S.A. 279104-YTG-B-0307 Copyright © by York International Corp. 2007. All rights reserved. Supersedes: 279104-YTG- A-1 106 Unitary 5005 Norman Product Y .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il York 036-048 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del York 036-048 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso York 036-048 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul York 036-048 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il York 036-048, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del York 036-048.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il York 036-048. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo York 036-048 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.