Exe/Devon/County Double Freestanding Double Sided Stove USER INSTRUCTIONS For use in Great Britain and Eire. This product is suitable for use in the stated countries. To install the product in other countries it is essential to obtain translated instructions and in some cases the product may require modification.
2 FOR YOUR RECORDS To assist us in any Guarantee claim please complete the following information:- Is flue system correct for the appliance YES NO Flue swept and soundness test complete YES NO Applian.
3 SERVICE RECORDS 1st SERVICE Date of Service: ..................................... Next Service Due: ................................... Signed: ............................................ Dealer’s Stamp/HETAS Registration Number 3rd SERVICE Date of Service: .
4 OPERATING INSTRUCTIONS Before using this appliance, please read these instructions fully. 1. GENERAL 1.1 This stove is designed for domestic heating and should only be used for this purpose, and in accordance with the manufacturers operating instructions.
5 OPERATING INSTRUCTIONS DOOR HANDLE To Open and Close Drop door tool over knob to fit. Rotate 1 / 2 turn anti-clockwise to open. Rotate 1 / 2 turn clockwise to close. Lift up door tool to remove PR7522 PR7523 Open Open 1.11 Never open the door with your bare hands.
6 OPERATING INSTRUCTIONS 4.9 Do not re-fuel the stove above the level of the log guards. 4.10 The ideal control settings to suit the particular installation and personal preferences will be established by experience in using the stove.
7 OPERATING INSTRUCTIONS 7. OVER FIRING 7.1 Do not use the appliance at maximum output for prolonged periods of time, or over fill the firebox with fuel, as this could result in over-firing.
8 Damp / Rainy days – These sometimes result in problems when lighting and maintaining the fire, due to the lower flue temperatures and smaller difference between indoor and outdoor temperatures reducing the flue draught. Also, rain water running down the inside of the chimney reduces the flue temperatures.
9 1. GENERAL CLEANING Before any cleaning is carried out, allow the stove to cool thoroughly to avoid risk of burns. 1.1 We would recommend that your Yeoman stove be cleaned fully on a regular basis, according to the level of use. Attention should be given to cleaning the baffle system, flueways and removing ash.
10 MAINTENANCE and SERVICING This is a list of the maintenance products you may need to use 4.15 These products, all available from your local Yeoman dealer, along with regular maintenance and use of the correct fuels, will help you to keep your stove in the best possible condition.
11 MAINTENANCE and SERVICING 6.5 Raise the other end of the baffle plate and attach the baffle extension tubes to the baffle pins, lower the baffle plate onto these tubes.
12 MAINTENANCE and SERVICING 7.6 Fit only Yeoman ceramic glass, which is suitable to use in high temperature applications. 7.7 Using the stove with a damaged door glass could cause dangerous fumes to enter the room, or the stove to overfire, resulting in damage.
13 BASIC SPARE PARTS LIST FOR DEVON/COUNTY SINGLE DOUBLE 1 10 12 13 11 2 8 7 6 9 3 4 5 Diagram No. Part No. Description 1 YM-YM00545 Devon/Exe/County 6" Cast Flue Spigot 2 YM-F00088 M6 x 30 Count.
14 BASIC SPARE PARTS LIST FOR EXE/DEVON DOUBLE DOUBLE 1 10 12 13 11 2 8 7 6 9 3 4 5 Diagram No. Part No. Description 1 YM-YM00545 Devon/Exe/County 6" Cast Flue Spigot 2 YM-F00088 M6 x 30 Counters.
15 BASIC SPARE PARTS LIST FOR COUNTY DOUBLE DOUBLE 1 10 12 13 11 14 2 8 7 6 9 3 4 5 Diagram No. Part No. Description 1 YM-YM00545 Devon/Exe/County 6" Cast Flue Spigot 2 YM-F00088 M6 x 30 Counters.
16 BASIC SPARE PARTS LIST FOR EXE/DEVON/COUNTY 1 DOOR 1 10 6 11 2 8 7 9 3 4 5 COMMON PARTS FOR EXE/DEVON/COUNTY 1 DOOR Diagram No. Part No. Description 1 4670 14mm Rope Seal Black 2 YM-F00001 M5 x 8 M.
17 BASIC SPARE PARTS LIST FOR EXE/DEVON/COUNTY 2 DOOR 1 10 12 13 11 14 15 17 18 16 2 8 7 6 9 3 4 5 COMMON PARTS FOR EXE/DEVON/COUNTY 2 DOOR Diagram No.
18.
19.
A division of Stovax Ltd Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474500 Fax: (01392) 219932 E-mail: yeoman@stovax.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Yeoman YM-W9121FL è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Yeoman YM-W9121FL - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Yeoman YM-W9121FL imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Yeoman YM-W9121FL ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Yeoman YM-W9121FL, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Yeoman YM-W9121FL.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Yeoman YM-W9121FL. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Yeoman YM-W9121FL insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.