Manuale d’uso / di manutenzione del prodotto TM-XDSL-01XN del fabbricante Xantrex
Vai alla pagina of 36
Operating M anual XDC 6000 Watt Series Slave Power Supply XDC 10-600SL XDC 20-300SL XDC 30-200SL XDC 40-150SL XDC 60-100SL XDC 80-75SL XDC 100-60SL XDC 150-40SL XDC 300-20SL XDC 600-10SL TM-XDSL -01XN.
TM-XDSL -01XN.book Page ii Tuesday, Novem ber 5, 2002 3:22 PM.
Operating Manual for XDC 600 0 Watt Series Slave P ower S upply TM-XDSL -01XN.book Page i Tuesday , Novemb er 5, 2002 3:22 PM.
ii Operating Manual for XDC Series Slave Pow er Supply Limited W arranty What does this warranty cov er and how long doe s it las t? This Lim ited W arranty is provided by Xantr ex T echnology, Inc. (“Xantre x”) and cove rs defe cts in work manship a nd mate rials in y our X DC 6000 W att Ser ies Slave Power Supply .
Release 1.0 iii Direct returns m ay be perfo rmed ac cording to the Xantr ex Return Mat erial Authoriza tion Polic y describe d in your fr ont panel co ntrolle d XDC product manual . For som e product s, Xantrex m aintai ns a netwo rk of regio nal Authoriz ed Servic e Centers .
iv Operating Manual for XDC Series Slave Pow er Supply Disclaimer Product THIS LIMITED WARRA NTY I S THE SOLE AND EXCLUSIVE W ARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YOUR XANTREX PRODUCT AND IS.
Release 1.0 v Information WITHOUT LIMITI NG THE GENERALIT Y OF THE FOREGOING, UNLESS SPECIFICALL Y AGREED TO BY IT IN WRITING, XANTREX a. MAKES NO WARRANTY AS TO THE ACCURACY , SUFFICIE NCY OR SUIT ABILI TY OF ANY TECHNIC AL OR OTHER INFORMA TION PROV IDED IN MANUALS OR OTHER DOCUMENT A TION PROVI DED BY IT IN CONNECTION WITH THE PRODUCT ; AND b.
vi Operating Manual for XDC Series Slave Power Supply Wa r n i n g s and Caution s W arning s and cautio ns are de fined and form atte d in this ma nual as sho wn below .
Release 1.0 vii A pprovals CE Mark CE-m arked units meet the foll owing s tandards: • IEC 1010-1- 92 including Am endments 1 and 2: • Overvo ltage Categor y II • Perma nently Connect ed Equipmen.
viii Operating Manual for XDC Series Slave Pow er Supply TM-XDSL -01XN.book Pag e vi ii Tuesday, N ovem ber 5, 2002 3:22 PM.
Release 1.0 ix Ab out This M anual Thi s Operati ng Manu al contain s operati ng inst ructi ons for th e XDC Se ries Sla ve power supplies. This po wer supply is based on the XD C Series o f digita l,.
Abo ut This Manual x Operating Manual for XDC Series Slave Pow er Supply TM-XDSL -01XN.book Pag e x T uesday, Nov emb er 5, 2002 3: 22 PM.
Release 1.0 xi Table of Cont ents About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ix Table of Cont ents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T able of Co nten ts xii Operating Manual for XDC Series Slave Pow er Supply TM-XDSL -01XN.book Page xi i Tuesday, Nov ember 5, 2002 3:22 PM.
Release 1.0 13 Sectio n 1. Ov ervie w The XDC serie s Slave power supply is desig ned for use in current sha ring sy st ems as a sl ave m odule co nnected in para llel w ith an XDC 6000 W att series full digit al contro lled fro nt panel unit.
Overview Front Panel 14 Operating Manual for XDC Series Slave Pow er Supply Front Panel Figure 1.1 Slave Front Panel 1. Rack m ount brack ets 2. Handles 3. ON/OFF Switc h 4. Power On status L ED (gree n) 5. Ouput Off status LED ( red) Lit when the out put is disable d 6.
AC In put Pow er Front Panel Release 1.0 15 Sectio n 2. AC I nput Power WA R N I N G Disconn ect AC power from the un it before removing t he connector cover . Live line voltag es may be exposed when the cover is removed. WA R N I N G A safety groun d w ire must be connected to the unit as s how n in Figure 2.
AC Inp ut Pow er AC Input Connector 16 Operating Manual for XDC Series Slave Pow er Supply A C Input Connector The AC input connec tor is a standard w ire cla mp ter minal blo ck wi th 3-phase connect ors and a c hassis g round connec tor .
AC In put Pow er AC W ir e Input Connectio n Release 1.0 17 A C Wire I npu t Connection See Figur e 2.2, on page 18. T o conn ect the AC inpu t wires: 1. Ensure tha t the AC i nput cord is de-e nergized, and t hat the po wer s witc h on the front o f the powe r supply is OFF .
AC Inp ut Pow er AC W ire I nput Conn ection 18 Operating Manual for XDC Series Slave Pow er Supply Figure 2.2 Attaching the AC Input W ires TM-XDSL -01XN.
Current Sharing Overview Release 1.0 19 Sectio n 3. Cu rrent Sh ari ng Overview Power supplies equipped w ith the CANbus int erfac e will allow current s haring betwee n units connec ted in paral lel. Curre nt sharing c an use a m aximum of 5 supplies, inc luding the ma ster .
Current Sharing Overview 20 Operating Manual for XDC Series Slave Pow er Supply CA Nbus Setu p The CANbus port is a one mal e, one fem ale DB9 co nnector t o support “dais y c hain” connect ions. The CAN (Co ntrolle r Area Ne twork ) is an I SO standar d (ISO1 1898) for a seria l co mmunic ation ne twor k.
Current Sharing Overview Release 1.0 21 Current Share Configurati on Uni ts are progr ammed in a mod e such th at it is al ready in curr ent shar ing mode on power up. This feature is not user- modifi able. Plea se cont act the m anufact urer for assis tance if yo u wish to change thi s.
Current Sharing Operation 22 Operating Manual for XDC Series Slave Pow er Supply Operation There can o nly be one ma ster unit and 4 slave unit s current sharing. All other units will no t current s hare. Units must hav e the sam e o utput rating s or they w ill not current s hare.
Release 1.0 23 Appendi x A. S peci fi catio ns and Characte risti cs Notes • These specif ications are represented over the full operating temperature range. • Nominal line input volt age assumed unless otherwise stated. • All sense l ines are configured for default l ocal operation.
Specifications and Characteristics Electrical Specifications—Summary 24 Operating Manual for XDC Series Slave Pow er Supply Electrica l Specifications—Summ ary T able A .
Specifications and Characteristics Electrical Specifications—Summary Release 1.0 25 T able A .3 S pecificatio ns for 80V to 600V Models T able A .4 Dr if t S pec if ic ati ons f or 8 0V to 600V Models Models 80–75 100–60 150 –40 300–20 600– 10 Output Ratings: Output V oltage 1 Output Current 2 Output Power 1.
Specifications and Characteristics AC Line Input Specifications 26 Operating Manual for XDC Series Slave Pow er Supply A C Line Input S pecifications The input to the po wer supply re quires the follow ing spec ifica tions. A C Line Input Vo l t a g e Ope rating Ranges T able A .
Specifications and Characteristics Output Performance Specification s Release 1.0 27 Output Performance S pecifications These spec ifica tions def ine the ele ctric al perfo rmanc e specif icatio ns of the power supply output. These s pecific ations apply to both lo cal and re mote sense config urations , except whe re note d.
Specifications and Characteristics Output Performance Specif ications 28 Operating Manual for XDC Series Slave Pow er Supply T y pica l Programmi ng R esol uti on T y pica l Measureme nt Resolut ion Program ming A ccu racy 1 Readba ck A ccura cy 30 Minu te Drift 2 Remote Digital Interf ace V oltage Current Power Over V oltage Protection 0.
Specifications and Characteristics Output Performance Specification s Release 1.0 29 8 Hour Dri f t T empera ture St ability 1 T emperatur e C oef fi cien t s Switching Freq uency T y pica l 31 kHz; 62 kHz o utput ripple Rise Tim e 5 to 9 5% step in outp u t volt age.
Specifications and Characteristics Output Performance Specif ications 30 Operating Manual for XDC Series Slave Pow er Supply Time Dela y From Outp ut Enable Unti l Output St a ble 2 s max imum (W it h.
Specifications and Characteristics Environmental Specification Release 1.0 31 Environmenta l Specification Thermal Specification Humidity Specification International A pprovals CE-m arked units meet : EN61010-1, EN50081-2 and EN500082-2. CSA C/US certi fied to C22.
Specifications and Characteristics Mechanical Specification 32 Operating Manual for XDC Series Slave Pow er Supply Mechanical S pecification Weight App r ox. 75 lb. (34 kg) fo r 10 V - 600 A unit, witho ut packa ging Size Figure A .1 Power S upply Dimensions TM-XDSL -01XN.
TM-XDSL -01XN.book Page 33 Tuesday, Novem ber 5, 2002 3:22 PM.
Xantrex Tech nology In c. 8999 Ne lson Wa y Burnaby , British Columbia Canada V5A 4B5 604 422 277 7 T el 604 420 214 5 F ax 800 670 070 7 T oll Free North America customerservice@xantrex.com www.xantrex.com TM-X DSL-01X N PRINTED I N CANADA TM-XDSL -01XN.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Xantrex TM-XDSL-01XN è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Xantrex TM-XDSL-01XN - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Xantrex TM-XDSL-01XN imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Xantrex TM-XDSL-01XN ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Xantrex TM-XDSL-01XN, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Xantrex TM-XDSL-01XN.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Xantrex TM-XDSL-01XN. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Xantrex TM-XDSL-01XN insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.