Installation Instructions and Owner’s Manual Direct-Vent Wall Furnace - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GA S • Open all windows. • Do not try to light any appliance.
Table of Contents General Information a nd Technical Data This furnace is design certif ied to ANSI Z21.86-2004 / CSA 2.32-2004 Gas–Fire d Gravity and Fan-Type, Direct -Vent Wall Furnaces as a Fan-Type Direct-Vent Wa ll Furnace to be inst alled on an outsi de wall according to these in structions.
2 Safety Rules and General Warnings DO NOT OPERATE THIS FURNACE WITHOUT FRONT PANEL INSTALLE D • Due to high temperatures, the furnace should be located out of traffic and away from any combustible materials such as furniture and draperies.
Some Points to Remember • Learn to recognize the odor of LP Gas. Your local LP Gas dealer can give you a ”Scratch and Sniff” pa mphlet. Use it to find out what the propane odor smells like. If you suspect that your LP Gas has a weak or abnorm al odor, call your LP Gas dealer.
Installation Installation should be done by a QUALIFIED SERVICE TECHNICIAN. The furnace must be located on an outs ide wall. Wall Installation 4 Minimum clearances from combustible materials: WARNING:.
5 A. Clearance above grade, verand a, porch, deck or balcony 12-inches (30 cm ) minimum. (3) B. Clearance to window or do or that may be opened 12- inches (30 cm) minimum. (3) C. Clearance to permane ntly closed window minimum 12- inches (30 cm) recomme nded to prevent condensation on wind ow.
6 5. Install the supporting bracket to the wall; insert the air pipe in the wall through the hole provided in the support bracket . Place the round adhesive gasket around the hole so that the air pipe rem ains in position. (Figure 3) 6. Attach the supporting bracket with the screws.
7 12. Remove the vent cap an d drill all the necessary holes (diame ter ¼ inch for the screw fittings provided with th e furnace). 13. Relocate the vent cap and attach it with the screws. (Figure 7) 14. Attach the female end of the three-prong cord to t he receptacle lo cated near the bottom of the furnace.
8 ressure at the correct value Gas Conversions Converting to another gas type mu st be performed by a qualified service technician. If the type of the gas supplied to the dwelling is not the same type as your furnace (natural or LPG gas), it must be converted.
9 Gas Supply Check all local codes for requirements, esp ecially for the size and type of gas supply line required. On natural gas line s less than 15” (380 mm) long, use 1/2” tube; on longer runs, use 3/4” iro n tube or equal. On LP Gas lines please consult LP Gas supplier.
10 First Firing the Furnace Start the furnace following the instructions given in the “Opera ting Instructions”. The first lighting may be difficult becaus e of the air trapped in the gas line s. During initial firing of the fu rnace, resi dual manufacturing grease will bake out and smoke will occur which is not a health dan ger.
11 Electrical Wiring Diagram Key: EV, EV1 Gas Valve 1 (Safety S hutter) Vanne Gas 1 (Securite’) lamme ermostat ffe 0 size – 4A mbustion 2 pcs) p) ) V itch e’ - Hiver sse Ventil.
12 Operating Instructions Before operating the furnace, re fety information in this manual . ad carefully all wa rnings and sa A. Thi s appli ance do es not hav e a pil o t whic h m ust Fol l ow the gas suppli er' s instr uct ion s.
13 WHA T TO DO IF T HE RED LA MP I S LIT Thi s appl i ance has an el ect roni c f lam e superv i si on dev ic e. I f t he f lam e di sappears the gas f l ow w ill b e a uto matic ally shut of f and the red l am p wil l l i ght inst ead of t he green one.
14 Servicing All servicing activities must be performed by a qualified se rv ice t chnicia n or a service agency. The hom e owner may not e hecking and Adjusting the Gas Manifold Pressure manifold pressures as shown in “Technical Data”. It is roceed as follows: the HI mode.
Annual Maintenance Requirements 1. Clean fan blades. 2. Clean air blower. 3. Check and clean sili cone red pipes. 4. Check air flow switch. 5. Clean and check exhaust flue pipe a nd air intake pipe. Check red O-Ring G asket (NRNG003). If it is damaged, replace it.
16 Programmable Timer The programmable timer allows precise operating an d timing control and is standard on thi s furnace. (Figure 10) Overview The programmable timer has the following feature s: •.
17 Setting and Adjustment 1 2 3 4 5 6 7 0 :00 1 2 3 4 5 6 7 E EE 1 2 3 4 5 6 7 0 :00 1 2 3 4 5 6 7 0 :00 1 2 3 4 5 6 7 0 :00 ☼ 1 Initial Conditions A. Set the Setting/Regulator switch (Figure 10-B) in RUN position (ce nter). Press the Reset button R.
18 D. Press the Day Setting, (1……7, Figure 11-D) bu tton to program another day or block of days. E. To set further programs repeat steps item B through D above. NOTE: When the same ON and O FF times are desired for different days of the week, the setting procedu re may be simplified.
19 Troubleshooting Starting Sequence (Electrical) Step 1 1. Check L1 – L2 (Supply 120 V, 60 Hz) 2. Check M9 (Main fuse) Troubleshooting Step 1 Point 1 (L1-L2) No voltage (120 V). Check the electrical supply line, wirin g and connectio ns. Point 2 (M9) Fuse damaged.
20 Troubleshooting Step 3 Point 5 (Z1) Z1 is open and no ignition. Check wiring and conn ections. If everything is okay, replace the switch. Point 7 (M2) M2 is closed and fan thermostat temperature is lower than 104 °F. Check wiring and co nnections.
21 Point 13 (TR) No inlet voltage (120 V). Check 5 pole conne ctor and control box. If everything is okay, first replace the connector and then the control box if problem rem ains. No outlet voltage (24 V) during ignition. Check wiring and conn ections.
22 Replacement Parts TR – 120/24V Transforme r Part Number: JTRS017 Ignition Control Box Part Number: JCNT019 NP – Pressure Switch Part Number: JPRS010 Z9 – Room Thermostat Part Number: JTLT005 .
23 RP8 : Flame Sensor Part Number:JLTT015 RP7: Spark Igniter (2 piec es) Part Number: JLTT023 S – Combustion Blower Motor Part Number: JMTR017 M1 – Overheat Thermostat Part Number: JTLT006 M2 - Fa.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Williams 1773512 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Williams 1773512 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Williams 1773512 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Williams 1773512 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Williams 1773512, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Williams 1773512.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Williams 1773512. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Williams 1773512 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.