1 Blue 4” Univ er sal T her mostat with Automa tic Heat/Cool Changeo v er Option Single Stage, Multi-Stage or Heat Pump Installation and Operating Instructions for Model: F AILURE T O READ AND FOLLO W ALL INSTRUCTIONS CAREFULL Y BEFORE INST ALLING OR OPERA TING THIS CONTROL COULD CA USE PERSONAL INJUR Y AND/OR PROPER TY D AMAGE.
2 INST ALLA TION Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code. WA RNING ! Remove Old Thermostat A standard heat/cool thermostat consists of three basic par ts: 1. The cov er , which may be either a snap-on or hinge type .
3 Single Stage 1 (SS1) Multi- Stage 2 (MS2) O Energized Constantly in Cool Mode B Energized Constantly in Heat, Off, Emergency Mode No Output Cool Mode 2nd Stage Cool Mode 1st Stage Blower/ Circulator.
4 WIRING DIA GRAMS Figure 5 – Single Stage or Multi-Stage System (No Heat Pump) with T wo T ransf ormers Single Stage 1 (SS1) Multi- Stage 2 (MS2) No Output Cool Mode 2nd Stage Cool Mode 1st Stage B.
5 11 10 9 1 8 7 6 5 4 3 2 12 M o n t h C h a n g e F i l t e r C a l l F o r S e rv i c e S a v e T e m p H o l d P Date S e t Set Sc he du le S Y S T E M F A N Y ear R u n Hold Heat Mo T u W e Th Fr .
6 INST ALLER/CONFIGURA TION MENU With thermostat in Heat, Cool or Auto , in nor mal operation, press the Menu button f or at least 5 seconds. The displa y will show item #1 in the table belo w . Press Menu button to adv ance to the ne xt menu item. Press or to change an item option.
7 INST ALLER/CONFIGURA TION MENU 1) Ke ypad Lock out – This menu selection will display “ Lk” and “OFF” (def ault, ke ypad not loc ked out). The and are used to toggle the selection between OFF and “ L” (ke ypad lock ed out).
8 INST ALLER/CONFIGURA TION MENU reache d, trying to rais e or lo wer the s etpoint past t he lim it will c ause “L ” to be di spla yed in the ti mes dig its f or about 6 seconds. This feature not a vailab le on ear lier models. 16) Program Options: Configured for 7 da y or 5/1/1 day pro- gramming or non-prog rammable mode .
9 Set Current Time and Date 1) Press Menu and then Time button once. The display will show the hour only . 2) Press and hold either the or button until y ou reach the correct hour and AM/PM designation (AM begins at midnight, PM begins at noon). 3) Press TIME once again.
10 W orksheet for Re-Pr ogramming 7 Day and 5+1+1 Da y Program Cooling Program W ake Up (P eriod 1) Leave For W ork (P eriod 2) Return Home (P eriod 3) Go T o Bed (P eriod 4) MON 6:00 AM 75°F 8:00 AM.
11 Symptom P ossible Cause Correction Action No Heat/No Cool/No Fan (common problems) 1. Blown fuse or tripped circuit breaker . 2. Fur nace power s witch to OFF . 3. Fur nace blo wer compar tment door or panel loose or not properly installed. 4. Loose connection to ther mostat or system.
12 www .white-rodger s.com www . emersonclimate.com HOMEO WNER HELP LINE: 1-800-284-2925 White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and ser vice mark of Emerson Electric Co.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il White Rodgers 1F85-0477 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del White Rodgers 1F85-0477 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso White Rodgers 1F85-0477 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul White Rodgers 1F85-0477 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il White Rodgers 1F85-0477, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del White Rodgers 1F85-0477.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il White Rodgers 1F85-0477. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo White Rodgers 1F85-0477 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.