This thermostat is intended for use with a low v oltage NEC Class II system. Do not use this thermostat with a line voltage system. If in doubt about whether y our wiring is millivolt, line, or low v oltage, ha ve it inspected b y a qualifi ed heating and air conditioning contractor or electrician.
2 INST ALLA TION REMO VE OLD THERMOST A T 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electr ical power is disconnected. 2. Remov e the front cov er of the old thermostat. With wires still attached, remov e wall plate from the w all.
3 ENERGY MANA GEMENT RECO VER Y (EMR) When the EMR f eature is activated the thermostat’ s microcomputer calculates the time it will take to change the room temperature to the ne xt heat or cool program setting.
4 WIRING DIA GRAMS R C G W Figure 4. T ypical wiring diagram f or two transf ormer single stage systems with safety circuits in BO TH systems Changeov er Relay* Y O/B Compressor Contactor * Changeover.
5 The confi guration menu allo ws you to set certain ther mostat operating characteristics to your system or personal requirements. T o enter the menu: Set your thermostat to OFF and press the and buttons simultaneously . The display will show the fi rst item in the confi guration menu.
6 Cooling System 1. Mov e SYSTEM switch to COOL position. 2. Press to adjust ther mostat setting below room temperature. The blow er should come on immediately on high speed, f ollowed b y cold air circulation. Howe v er , if the setpoint temperature is fl ashing, the compressor loc kout f eature is operating (see Confi guration menu, item 6).
7 PR OGRAMMING PROGRAMMING Y OUR THERMOST A T This section will help you plan y our ther mostat’ s progr am to meet your needs . F or maximum comf or t and effi ciency , keep the f ollowing guidelines in mind when planning your prog ram.
8 7. Repeat steps 3 through 5 f or the 3rd and 4th heating program periods. 8. When you hav e completed enter ing your heating progr am, press R UN/HOLD . Enter Cooling Program 1. Mov e SYSTEM switch to COOL position. 2. Follo w Enter Heating Program f or enter ing your cooling program, using y our selected cooling times and temperatures.
9 TR OUBLESHOO TING Reset Operation If a voltage spik e or static discharge blanks out the display or causes erratic thermostat operation, reset the ther mostat by pressing the , and TIME buttons sim ultaneously .
10 NO TES.
11 NO TES.
www .white-rodgers.com White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and service mar k of Emerson Electric Co. Homeowner Help Line: 1-800-284-2925.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il White Rodgers 1F80-0224 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del White Rodgers 1F80-0224 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso White Rodgers 1F80-0224 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul White Rodgers 1F80-0224 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il White Rodgers 1F80-0224, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del White Rodgers 1F80-0224.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il White Rodgers 1F80-0224. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo White Rodgers 1F80-0224 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.