WTI Part No.: 12651 Rev. B RPB+ Remote Power Boot Switch User's Guide 5 Sterling, Irvine, California 92618-2517 USA U.S. & Canada: (800) 854-7226 Phone: (949) 586-9950 Fax: (949) 583-9515 www.wti.com Table of Contents 1. Introduction ● 2. Unit Description 2.
A. Specifications ● B. Customer Service ● List of Figures 1. Front Panel ● 2. Back Panel ● 3. RS-232 (Control Port) Interface Schematic ● 4. RPB+ Cable Connections ● 5. The Status Screen ● 1. Introduction Network equipment sometimes "locks-up", making it impossible to communicate.
Throughout this manual, typefaces and characters have been used to denote the following: COURIER FONT Indicates characters typed on the keyboard. For example, /S or /3 ON . [Bold Font] Text set in bold face and enclosed in square brackets indicates a specific key.
Switched AC Outlets (Plugs 1 - 5): For connection to up to five AC devices. Each outlet is capable of switching up to 15 Amps. The total for all five outlets must not exceed 15 Amps.
allows the user to invoke On/Off/Boot commands, but prevents redefinition of parameters such as the Password and Power-Up Default. Switch Function Up Down 1 Control Port Baud Rate 2400 bps 9600 bps* 2 Off Time 10 sec. 5 sec.* 3 Password Function Disable Enable* 4 Read Only Mode Enable Disable* * = Factory Setting 3.
string. 3.3. Power Connection The Power Switch located on the back panel must be "On" in order for the RPB+ to operate. Each time the unit is powered On, the five AC outlets will be switched On or Off, as dictated by the Power-Up Default String (see Section 4.
Password: If the Password function is enabled, the unit will display a prompt. Key in the Password and press [Enter] . If the password has not yet been defined, just press [Enter] .
during password definition. Default (Power-Up Default): Allows the user to define default On/Off conditions for each switched plug as described in Section 4.
Example 1: To set default On/Off conditions as follows: ON: Plugs 1 and 5 OFF: Plugs 2, 3, and 4 The Power-Up Default String would be defined as " 10001 ". Example 2: To set default plug conditions as follows: ON: Plugs 3, 4, and 5 OFF: Plugs 1 and 2 The Power-Up Default String would be defined as " 00111 ".
Enter Parameters: To define parameters, such as the Location I.D., Power-Up Default, and Plug Labels, type /P [Enter] and refer to Section 4 , Step 4. 5. Set Plugs to Default: To set all plugs to the Power-Up Defaults, type /D [Enter] . Note that if the Default String includes missing or invalid characters, the /D command will not function.
2 RXD Data Input 3 TXD Data Output 4 DTR Ready Output 5 GND Signal Ground 6 (NC) Not Connected 7 RTS RTS Output 8 (NC) Not Connected 9 (NC) Not Connected Coding: Asynchronous.
Irvine, California 92618 Toll Free (U.S. & Canada): 1-800-854-7226 Phone: 949-586-9950 Fax: 949-583-9514 EMail: service@wti.com FCC Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and 1.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Western Telematic Remote Power Boot Switch è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Western Telematic Remote Power Boot Switch - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Western Telematic Remote Power Boot Switch imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Western Telematic Remote Power Boot Switch ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Western Telematic Remote Power Boot Switch, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Western Telematic Remote Power Boot Switch.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Western Telematic Remote Power Boot Switch. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Western Telematic Remote Power Boot Switch insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.