PRINTED IN UNITED ST A TES OF AMERICA WELLS BLOOMFIELD , LLC 2 ERIK CIRCLE, P . O. Box 280 V erdi, NV 89439 telephone: 775-689-5707 fax: 775-689-5976 www .
712 76580 Owne rs Manual Hot Water Dispenser NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery.
MODEL VOLTS 1ø 50/60Hz WATTS AMPS 1ø POWER SUPPLY CORD 1222 120 1800 15.0 NEMA 5-15P 1222CA k 120 1500 12.8 1225 k 208 4000 19.0 1226 k 240 4000 16.5 NEMA 6-30P 1 TABLE OF CONTENTS SPECIFICATIONS Thank You for purchasing this Wells Bloomfield appliance.
FEATURES AND OPERATING CONTROLS 2 712 76580 Owne rs Manual Hot Water Dispenser.
PRECAUTIONS AND GENERAL INFORMATION 3 WARNING: ELECTRIC SHOCK HAZA RD All servicing requiring access to no n-in sulat ed components must be performed by qualified service personnel. Do not open any access panels which requi re the use of tools. Failure to heed this warnin g can result in electri cal shock.
INSTALLATION 4 READ THIS CAREFULL Y BEFORE ST ARTING THE I NST ALLA TION REFER TO EXPLODED VIEWS PAGE 14 FOR COMPONENT NAMES/NUMBERS. Unpack the unit. Inspect all component s for completeness and condition. Ensure that all packing materials have bee n remove d from the unit.
INSTALLATION (continued) 5 NOTE: This equipment m ust be installed to comply with applicable federal, state and local plumbing codes and ordinances. CAUTION: SHOCK HAZARD Dispenser must be prope rly grounded to prevent possible shock hazard. DO NOT assume a plumbing line wil l provide such a ground.
OPERATION 6 Fig. 3 Dispenser Operation Diag ram A. START-UP For initial start-up, or if the disp en ser has not been used for an extended period of time: • Be sure the water supply is properly connected and the water supply valve is turned ON . • Be sure the WATER TANK IS FILLED.
CLEANING INSTRUCTIONS PROCEDURE: Clean Hot Water Dispenser PRECAUTIONS: Disconnect di spenser from electric power. Allow dispenser to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush 1. Disconnect dispe nser from electric power.
TROUBLESHOOTING SUGGESTIONS SUGGESTED REMEDY Check power sup ply cord Check / reset cir cuit breaker Press switch to "ON" Adjust thermostat for desired temperature Allow to cool hi-limit wil.
SERVICING INSTRUCTIONS CAUTION: SHOCK HAZARD Opening access panels on this dispenser may expose uninsulated electrical components. Disconnect dispenser from electrical power before removing any panel.
SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT Check temperature at discharge of faucet. Remove thermostat access butt on plug to ac cess thermostat. Turn thermostat shaft clockwis e to increase temperature. REMOVE TANK LID ASSEMBLY Unplug dispense r or turn circuit brea ker OFF .
SERVICING INSTRUCTIONS (continued) IMPORTANT: When replacing heating element, also replace seal gaskets. NOTE: Any abrasion or roughness on the flat end of the seat cup will require replacing the seat cup: REPLACE HEATING ELEMENT Remove tank lid assembly as detailed on page 10.
CAUTION: CHEMICAL BURN HAZARD Deliming chemicals may be caustic. Wear appropriate protective gloves and goggles during this procedure. Ne ver siphon deliming chemicals or solutions by mouth. This operation should only be performed by qualified and experienced service personnel.
EXPLODED VIEWS AND PARTS LISTS 13 SERVICE KITS FAUCET REPAIR KITS 84686 Faucet & Shank Complete 8700-25 L Seat Cup (only) SOLENOID REPAIR KITS 83612 Solenoid Complete, Single 120V (1222 , 1222CA) .
EXPLODED VIEW & PARTS LIST 14 NOTE: Model 1225/1226 shown. Model 1222/12 22 CA is similar. 712 76580 Owne rs Manual Hot Water Dispenser 38 39 37 1 34 27 2 REQD 36 28 35 31 29 40 18 26 24 22 21 21 .
EXPLODED VIEW & PARTS LIST (continued) 15 ITEM DESCRIPTION 1222 P/N 1222CA P/N 1225 P/N 1226 P/N 1 WRAP, BODY 2 TANK ASSY 3 PANEL, TOP BACK 4 PLUG, BUTTON 7/8" 8705-36 8705-36 8705-36 8705-36.
WIRING DIAGRAM 16 2-GALLON MODELS 1222 and 12 22CA 712 76580 Owne rs Manual Hot Water Dispenser 7 7 9 10 12 13 6 8 3 2 5 4 11 1 BLACK WHITE GREEN WHITE WHITE WHITE GREEN WHITE WHITE WHITE BLACK BLACK .
WIRING DIAGRAM (continued) 17 5-GALLON MODELS 1225 and 12 26 712 76580 Owne rs Manual Hot Water Dispenser MODEL 1225 and 1226 W A TER LEVEL CONTROL BOARD MAX COMM COMM N.O. N.C. INPUT BLACK WHITE GREEN WHITE WHITE WHITE RED 12 ga. RED 12 ga. WHITE GREEN WHITE BLACK 12 ga.
Genuine Parts Protect - YOU - All - W ays SER VICE TRAINING - QUALITY SER VICE SER VICE TRAINING - QUALITY SERVICE CUSTOMER SA TISF ACTION CUSTOMER SA TISF ACTION Wells Bloomfield proudly supports CFE.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Wells 1222 1222CA è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Wells 1222 1222CA - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Wells 1222 1222CA imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Wells 1222 1222CA ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Wells 1222 1222CA, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Wells 1222 1222CA.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Wells 1222 1222CA. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Wells 1222 1222CA insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.