Part number 550-141-396/0801 Electric-Hydr onic Boilers Installation Instructions These Instructions must be used only b y a qualified installer/service technician. Re a d these instructions completely bef ore beg inning. F ailure to follow these instructions can cause sev ere personal injury , death or substantial pr operty damage.
Part number 550-141-396/0801 2 PER Series 3 Electric-Hydronic Boilers Installation Instructions Please read before proceeding Failure t o adhe re t o the guid elines on this pag e can res ult in sev er e pers onal inju ry , death or substantial pr oper t y damage.
Part number 550-141-396/0801 3 PER Series 3 Electric-Hydronic Boilers Installation Instructions Mounting the boiler N ormally , the bo iler will be installed against a fr ame or masonry wall. If the wal l surface is r ough or uneven , it may be necessary to mount plywood on the wall, then mount the boiler o n the plywood.
Part number 550-141-396/0801 4 PER Series 3 Electric-Hydronic Boilers Installation Instructions Piping the boiler After the bo iler is secured to the wall, attac h the suppl y and return piping. R efer to T able 2 for minimum pipe sizes. Install manual shu t-off valves in the sup ply and r etu rn lines to facilitate se r vicing the boiler .
Part number 550-141-396/0801 5 PER Series 3 Electric-Hydronic Boilers Installation Instructions Sequence of operation Call for heat 1. The thermostat contacts c lose, energizing the first co ntactor (2K), the cir culator rela y (1K), and the heate r in the first thermal time delay (H1).
Part number 550-141-396/0801 6 PER Series 3 Electric-Hydronic Boilers Installation Instructions Wiring P ar t Number 550-224-719/0801 Legend HIGH VOL T AGE FACTORY WIRING LOW VOLTAGE FACTORY WIRING HIGH VOL T AGE FIELD WIRING LOW VOLTAGE FIELD WIRING A United Dominion Company Weil-McLain • 500 Blaine St.
Part number 550-141-396/0801 7 PER Series 3 Electric-Hydronic Boilers Installation Instructions T roubleshooting Symptom—No heat 1 . Check fuses. Po wer for the contr ol circuit is supplied thr ough the fuses for the heating element, and the circulato r .
Part number 550-141-396/0801 8 PER Series 3 Electric-Hydronic Boilers Installation Instructions Operating instructions W ater tr eatment Do not use pet roleum-based c leaning or sealing compounds in boiler system. Sever e damage to boiler will result, causing substantial property damage.
Part number 550-141-396/0801 9 PER Series 3 Electric-Hydronic Boilers Installation Instructions Check out procedure After filling and purging, start the boiler as follows: ❏ T urn the thermostat to its lowest setting so that there is no call for heat.
Part number 550-141-396/0801 10 PER Series 3 Electric-Hydronic Boilers Installation Instructions Maintenance Draining and cleaning Do not drain the boiler during periods of shutdown unless the heating system is expose d to freezing temperatur es.
Part number 550-141-396/0801 11 PER Series 3 Electric-Hydronic Boilers Installation Instructions Handling fiberglass materials REMO V AL OF FIBERGLASS WOOL — OR — INST ALLA TION OF FIBERGLASS WOOL.
Part number 550-141-396/0801 12 PER Series 3 Electric-Hydronic Boilers Installation Instructions Dimensions 39603 Incoming power 1 ¼ " conduit 6 ½ " 2 ¼ " 19 " 5 8 / 31 " 3.
Part number 550-141-396/0801 13 PER Series 3 Electric-Hydronic Boilers Installation Instructions 60% 70% 80% 90% 100% 200 210 220 230 240 In p u t V o lta g e P ercen t o f Rated C a p acity 39601 Rat.
Part number 550-141-396/0801 14 PER Series 3 Electric-Hydronic Boilers Installation Instructions P arts This boiler co ntains fiberg lass materials. U se care when handling these materials per instructions on page 11 of this manual. Failure to c omply c ould result in sever e personal injur y .
Part number 550-141-396/0801 15 PER Series 3 Electric-Hydronic Boilers Installation Instructions P arts continued The following items ar e available but ar e not sho wn in the Parts drawing Descriptio.
16 Part number 550-141-396/0801 W eil-McLain Limited W arranty for Residential & Commercial Cast Iron Boilers ◆ ◆ ◆ ◆ ◆ RESIDENTIAL W A TER W ARRANTY—Limited Lifetime ◆ ◆ ◆ ◆ .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Weil-McLain 550-141-396/0801 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Weil-McLain 550-141-396/0801 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Weil-McLain 550-141-396/0801 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Weil-McLain 550-141-396/0801 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Weil-McLain 550-141-396/0801, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Weil-McLain 550-141-396/0801.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Weil-McLain 550-141-396/0801. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Weil-McLain 550-141-396/0801 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.