Manuale d’uso / di manutenzione del prodotto WLP 4170 CCD del fabbricante Wasp
Vai alla pagina of 40
Wasp WLP 4170 CCD Programming Guide Please Read Note: The W asp WLP 4170 CCD Scanner is ready to scan the most popular bar codes out of the box. This manual should only be used to make changes in the configuration of the scanner for specific applications.
© Copyright W asp T echnologies 2002. All rights reser v ed. V ersion 1.0 No part of this publication may be reproduced or transmitted in any for m or by any means without the written permission of W asp T echnologies . The information contained in this document is subject to change without notice .
T able of Contents Chapter 1. Introduction.............................................................................. 1 Chapter 2. Installation................................................................................ 2 Chapter 3. Quick Star t .
1 Chapter 1 Introduction Bar coding is the most common Automated Data Collection (ADC) technology providing timely, error-free information that can be used to increase productivity , accuracy, and efficiency in the workplace . Virtually ev ery type of industry is using bar codes to replace k eyboard data entr y .
2 1. T urn off your computer . 2. Unplug your PC k e yboard cable and plug the male end (Din 5) of the Wasp WLP 4170 CCD Scanner directly into your PC k e yboard port. Plug your k e yboard cable into the other end (female Din 5) of the the W asp WLP 4170 CCD Scanner.
3 Y our W asp WLP 4170 CCD Scanner is ready to go . The default settings of the W asp WLP 4170 CCD Scanner ha v e been pre-prog r ammed for the most common bar code configurations . Use the "Setup & Configuration" sections only to customize the Wasp settings.
4 Bar codes are symbols consisting of a series of bars and spaces which can be applied to packages, cartons, bottles, and other commercial products . The bars and spaces in each symbol are grouped in such a w a y to represent a specific ASCII character or function.
5 In order to configure W asp WLP 4170 CCD Scanner, you must familiariz e y ourself with the setup procedures on the following pages . The default settings of W asp WLP 4170 CCD Scanner are identified on each page and clearly mar k ed using an asterisk (*).
NOTE: Scanning these bar codes returns the scanner to the factory default settings 1. Scan “Begin ” 2. Scan “Default” to restore scanner to default settings 6 Tip: Use this configuration to restore the factory default settings if you are unsure how your scanner has been configured.
7 Setup & Configuration —Beep and Dela y Beep V olume Settings 00 None 01 Lowest 02 Low 03 Medium (Default) 04 Medium-High 05 High 06 High-Medium 07 Highest The 'Beep V olume' configuration changes the volume of the audible indicator of the WLP 4170 CCD Scanner .
8 Setup & Configuration —Interc haracter Dela y Inter character Delay Settings 00 Slo w est 01 Slo w 02 Default 50 Medium 75 F ast 99 F astest The 'Intercharacter Delay' configuration sets the speed at which the WLP 4170 CCD Scanner sends data.
9 Setup & Configuration —Ke yboard W edg e 00 K eyboard Present* 01 Laptop/No k e yboard The 'Ke yboard W edge' configuration supports options related to managing ke yboard operations . The 'Function Code' option enables/disables support for your ke yboard function k eys.
*Default 00 Default* 04 Continuous 10 Setup & Configuration —Scanning Modes Begin Set Scanning Mode Exit The 'Scanning Mode' option controls the trigger and LED settings for the WLP 4170 CCD Scanner. NOTE: For help in configuring these settings, consult the programming steps on pa ge 5.
Preamble Data P ostamble 11 Setup & Configuration —Preamble and Postamble *Default The 'Preamble' and 'Postamble' options are used to add prefix and suffix characters to the bar code value . Up to 22 characters may be added for each option separately .
12 Setup & Configuration —Code 39 Co de 39 i s v a ri a b le leng t h a n d i s th e most fr equ e n tly use d s ymb olog y in indus t r i a l ba r co d e sys tem s toda y and is e x t e n s i v el y use d wit hi n t he Dep ar tme nt o f D ef e n s e ( D O D ) .
13 Setup & Configuration —Code 39 (cont.) St andar d Co d e 3 9 co n t a i n s o nly 4 3 cha ra ct ers (0- 9 , A-Z , $, / , % , +, - , . , SP A C E ) a nd ca n b e e xtend ed to a 12 8 c ha r a .
14 (continued on next page) *Default Setup & Configuration —Code128 On/Off V erify Check Digit Begin T ransmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable 01* Disable 00* Enable 01 NOTE: For help in configuring these settings, consult the programming steps on pa g e 5.
15 Setup & Configuration —Code128 (cont.) Set Maximum Length Set Minimum Length Begin Format Exit Option Alpha/Numeric Entr y (Back Flap) 64 - Minimum 00 - 64 00* 64 - Maximum 00 - 64 00* Standard 00* UCC/EAN-128 01 NOTE: For help in configuring these settings, consult the programming steps on pa ge 5.
16 Setup & Configuration —UPC-A On/Off V erify Check Digit Begin T r ansmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable (two digits) 01* Disable 00 Enable 01* NOTE: For help in configuring these settings, consult the programming steps on pa g e 5.
17 Setup & Configuration —UPC-A (cont.) Begin Supplement Digits T r uncate Leading Zero Exit NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. The first six digits of the UPC-A bar code are assigned from the Uniform Code Council (UCC).
18 (continued on next page) *Default Setup & Configuration —UPC-E On/Off V erify Check Digit Begin T ransmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable 01* Disable 00 Enable 01* NOTE: For help in configuring these settings, consult the programming steps on pa ge 5.
19 *Default Setup & Configuration —UPC-E (cont.) Supplement Digits T runcate Leading Zero Begin Expansion Exit NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. The printed value of the UPC-E code is a twelve digit code .
20 (continued on next page) *Default Setup & Configuration —EAN-13 On/Off V erify Check Digit Begin T ransmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable 01* Disable 00 Enable 01* NOTE: For help in configuring these settings, consult the programming steps on pa ge 5.
21 Setup & Configuration —EAN-13 (cont.) NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. The EAN/JAN-13 (European Article Number/Japanese Article Number) is fixed length and is similar to the UPC-A symbology, but encodes a 13th digit.
22 (continued on next page) *Default Setup & Configuration —EAN-8 On/Off V erify Check Digit Begin T ransmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable 01* Disable 00 Enable 01* NOTE: For help in configuring these settings, consult the programming steps on pa g e 5.
23 *Default Setup & Configuration —EAN-8 (cont.) Supplement Digits T r uncate Leading Zero Begin Expansion Exit Option Alpha/Numeric Entr y (Back Flap) None 00* 2 digits 01 5 digits 02 2 / 5 digits 03 or None Disable 00* Enable 01 Disable 00* Enable 01 NOTE: For help in configuring these settings, consult the programming steps on pa g e 5.
24 Setup & Configuration —Code 93 On/Off V erify Check Digit Begin T ransmit Check Digit Set Maximum Length Set Minimum Length Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00* Enable 01 .
25 Setup & Configuration —Interleaved 2 of 5 *Default Begin On/Off V erify Check Digit T ransmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable 01* Disable 00* Enable 01 NOTE: For help in configuring these settings, consult the programming steps on pa g e 5.
26 Setup & Configuration —Codabar *Default On/Off V erify Check Digit Begin T ransmit Check Digit Set Maximum Length Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00* Enable 01 Disable 00* Enable 01 64 - minimum 64 - 00 00* NOTE: For help in configuring these settings, consult the programming steps on pa ge 5.
27 *Default Setup & Configuration —Codabar (cont.) Set Minimum Length Start/Stop T ype Begin Start/Stop T ransmission Exit Option Alpha/Numeric Entr y (Back Flap) 00 - Maximum 00 - 64 00* ABCD/A.
28 Setup & Configuration —MSI Plesse y On/Off V erify Check Digit Begin T ransmit Check Digit Set Maximum Length Set Minimum Length Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00* Enabl.
29 Setup & Configuration —PDF417 On/Off Begin Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00* Enable 01 NOTE: For help in configuring these settings, consult the programming steps on pa g e 5. PDF417 is a 2D variable length symbology that can encode virtually any letter, number, or character .
30 Code 39* Interleav ed 2 of 5 Codabar* Code 128* MSI/Plesse y Code 93* Setup & Configuration —Bar Code T est Symbols—Appendix A Note: Make sure that the appropriate bar code symbology is configured properly and enabled before trying to scan.
31 UPC-A* UPC-E* UPC-E w/5 digit supplement UPC-E w/2 digit supplement UPC-A w/2 digit supplement UPC-A w/5 digit supplement Setup & Configuration —Bar Code T est Symbols—Appendix A (cont.
EAN/J AN 13* EAN/J AN 13 w/2 digit supplement EAN/J AN 13 w/5 digit supplement 3 Setup & Configuration —Bar Code T est Symbols—Appendix A (cont.
EAN/JAN 8* EAN/JAN 8+5 w/5 digit supplement EAN/JAN 8 w/2 digit supplement PDF417 33 Setup & Configuration —Bar Code T est Symbols—Appendix A (cont.
34 Setup & Configuration —WLP 4170 CCD Specifications MODEL WLP 4170 OPTICAL Scanning Width 3.2 in (120 mil) Depth of Field 0 to 3 in (0 to 200 mil) Scan Rate 200 scans / second ELECTRICAL Light Source 660 nm red visible LED Sensor 2,048 pixel CCD arr a y Operating V oltage +5 VDC ± 0.
35 W asp Bar Code products are warranted against defects in workmanship and materials for a period of one year from the date of shipment, provided that the product remains unmodified and is operated under normal and proper conditions.
43 C 44 D 45 E 46 F 47 G 48 H 49 I 4A J 4B K 4C L 4D M 4E N 4F O 50 P 51 Q 52 R 53 S 54 T 55 U 56 V 57 W 58 X 59 Y 5A Z 5B [ 5C 5D ] 5E ^ 5F _ 60 ` 61 a 62 b 23 # 24 $ 25 % 26 & 27 ‘ 28 ( 29 ) 2A ★ 2B + 2C 2D - 2E .
0 1 2 3 4 5 6 7 8 9 A B C D E F FINISH BACK COVER BAR CODES.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Wasp WLP 4170 CCD è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Wasp WLP 4170 CCD - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Wasp WLP 4170 CCD imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Wasp WLP 4170 CCD ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Wasp WLP 4170 CCD, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Wasp WLP 4170 CCD.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Wasp WLP 4170 CCD. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Wasp WLP 4170 CCD insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.