Manuale d’uso / di manutenzione del prodotto ML-135342-00060 del fabbricante Vulcan-Hart
Vai alla pagina of 22
ITW Food Equipment Group, LLC 3600 North Point Blvd. Baltimore, MD 21222 FORM F-36986 (Rev . 11-0 8) SERVICE MANUAL Heavy Duty Gas Griddles MODEL MLS 24RRG ML-135339-00024 36RRG ML-135340-00036 48RRG ML-135341-00048 60RRG ML-135342-00060 www.vulcanhart.
- 2 - TABLE OF CONTENTS INSTALLATION………………… …………………………… ………….. OPERATION……………………… ………………………… …………... CLEANING……………………… …………………………… ………….
- 3 - BURNER…………………………… …………………………………….. BURNER TROUBLESHOOTING …………… …………………………. BURNER REMOVAL ………………………… …………………………. BURNER ADJUSTMENT …………………………………… ………….
- 4 - GENERAL INTRODUCTION This manual is prepared for the use of trained service technicians and should only be used by those who are properly qualified.
- 5 - COMPONENT LOCATION TEMPERATURE CONTROLLER 498438 SAFETY IGNITION MODULE 498443 DUAL SOLENOID VA LVE 713656 GAS MANIFOLD 720122 PILOT SPARK ASSEMBLY 713930 INDICATOR LIGHT 720017 POWER SWITCH 810.
- 6 - EXTERIOR PANELS CONTROL PANEL Disconnect the electrical power and follow lockout / tagout procedures The Control Panel holds the thermostats, indicator lights and power switch. REMOVAL 1. Remove the four screws securing the front of the control panel.
- 7 - THERMOSTAT The thermostat is a solid state control. The thermostat supplies power to the burner solenoid valves and indicator lights when turned on or until the temperature setpoint is r eached. Disconnect the electrical power and follow lockout / tagout procedures THERMOSTAT TROUBLESHOOTING SYMPTOM – BURNER WILL NOT COME ON 1.
- 8 - Disconnect the electrical power and follow lockout/tagout procedures THERMOSTAT REMOVAL 1. Remove the control panel 2. Remove the knob 3. Label and disconnect the wires 4. Remove the thermostat retaining nut on the knob shaft. 5. Reverse procedure to install while being careful to install the thermostat in the same orientation.
- 9 - ADJUSTMENTS CALIBRATION 1. Each temperature controller c ontrols a 12” zone of the gri ddle. Using a Surface Probe temperature measurement device, observe the temperatur es at the cente r points of t he cooking zone s.
- 10 - POWER ON/OFF SWITCH The Power Switch controls the power supply to all other electronic com ponents. Disconnect the electrical power and follow lockout / tagout procedures POWER SWITCH TROUBL ESHOOTING SYMPTOM – NO POWER BEING SUPPLIE D TO THE UNIT 1.
- 11 - INDICATOR LIGHT The indicator light illuminates fully to indicate that the corresponding ther mostat and burner have turned on and gas is flowing through the corresponding solenoid valve.
- 12 - Disconnect the electrical power and follow lockout / tagout procedures SAFETY IGNITION MODULE TROUBLES HOOTING SYMPTOM – NO SPARK BETWEEN PILOT HEAD AND EL ECTRODE 1. Check for loose or greasy/dirty connections at all terminals (including electrode wire) 2.
- 13 - Disconnect the electrical power and follow lockout / tagout procedures SOLENOID VALVE TROUBLESHOOTI NG SYMPTOM – NO GAS FLOW TO BURNER 1. Check terminals for loose or greasy/dirty connections 2. Check gas pressure – check for orifice obstructio ns.
- 14 - PILOT The RRG Series Griddles utilize a solenoid valve with a brass pilot valve to control gas flow to pilot burners. One to three pilot flames can be fed by one valve – one leg of which may be branched. PILOT TROUBLESHOOTING SYMPTOM – PILOT WILL NOT LIGHT 1.
- 15 - HELPFUL HINT – If the unit is attached to a flexible gas line, you can extend the bullet feet out t o their fullest extension to raise the griddle and allow yourself more clearance while reaching under the unit. Remember to relevel the unit if you chose to do this.
- 16 - 2. Reach through the back of the unit. Squeeze the burner retaining clip and slide off burner retaining pin. 3. Lift the burner up so the retaining pin clears the corresponding hole in th e chassis, then pull the burner out through the back of the unit.
- 17 - GAS REGULATOR REGULATOR INSTALLED IN A HORI ZONTAL, UPRIGHT POSITION The RRG series units must have an exterior machine gas regulator installed. The units are shipped with a regulator that has a vent limiter. These regulators must be installed as close as possible to the unit in a horizontal, upright position for optimal performance.
- 18 - 12. Turn power switch and gas supply back on. All gas joints disturbed during ser vicing must be checked for leaks. Check with a soap and w ater soluti on. Do not use an open flame. PRESSURE TAP AT #1 BURNER SEQUENCE OF OPERATION Operation is the same for all size griddles.
- 19 - WIRING DIAGRAMS WIRING DIAGRAM – 24-INCH GRIDDLE.
- 20 - WIRING DIAGRAM – 36-INCH GRIDDLE.
- 21 - WIRING DIAGRAM – 48-INCH GRIDDLE.
- 22 - WIRING DIAGRAM – 60-INCH GRIDDLE.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Vulcan-Hart ML-135342-00060 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Vulcan-Hart ML-135342-00060 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Vulcan-Hart ML-135342-00060 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Vulcan-Hart ML-135342-00060 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Vulcan-Hart ML-135342-00060, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Vulcan-Hart ML-135342-00060.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Vulcan-Hart ML-135342-00060. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Vulcan-Hart ML-135342-00060 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.