Manuale d’uso / di manutenzione del prodotto 260L77R del fabbricante Vulcan-Hart
Vai alla pagina of 20
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791 SER VICE AND P AR TS MANUAL FOR ECONOLINE SERIES GAS REST AURANT RANGES MODELS: 36L77R, 36FL77R, 60L77R, 60FL77R, 160L.
– 2 – ECONOLINE SERVICE AND PARTS IMPORT ANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
– 3 – ECONOLINE SERVICE AND PARTS SER VICE AND P AR TS MANU AL ECONOLINE SERIES GAS REST A URANT RANGE - INDEX PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE Your Vulcan Econoline Range is produced with quality workmanship and material. Proper installation, usage and maintenance of your range will result in many years of satisfactory performance.
– 4 – ECONOLINE SERVICE AND PARTS WARNING: THE RANGE AND ITS PARTS ARE HOT. BE VERY CAREFUL WHEN OPERATING, CLEANING OR SERVICING THE RANGE. CONTROLS (FIG. 1) Thermostat Dial — allows operator to regulate oven temperature from low to 500 ° F. Open Top Burner Valve Knob — regulates gas flow to top burners.
– 5 – ECONOLINE SERVICE AND PARTS Open Top Pilots 1. Remove all top section cover plates and griddles. 2. Turn main gas supply ON (all burner valve knobs should be in OFF position). 3. Begin from the left range top side. Light each indi- vidual pilot from front to rear across the entire range top section.
– 6 – ECONOLINE SERVICE AND PARTS Pilot Burner Adjustment (Grayson Safety Valve Shown) 1. Remove pilot adjusting cap. 2. Adjust pilot key to provide properly sized flame.
– 7 – ECONOLINE SERVICE AND PARTS THERMOSTAT (BJWA) To Adjust By-Pass Flame (Minimum Burner Flame): When oven reaches the temperature at which the dial is set, the oven control cuts down the flow of gas to the amount required to keep the oven at that temperature.
– 8 – ECONOLINE SERVICE AND PARTS OVEN CONTROL RECALIBRATION NOTE: Do not recalibrate oven control until the by-pass flame has been adjusted. The oven is a precision instrument. It is carefully cali- brated at the factory so that the dial settings match the actual oven temperatures.
– 9 – ECONOLINE SERVICE AND PARTS ORIFICE DATA OPEN TOP GRIDDLE BROILER OVEN GRIDDLE INPUT AT SEA LEVEL 15,000 15,000 10,000 35,000 PER BURNER (BTU'S) GAS TYPE NAT/PROP NAT/PROP NAT/PROP NAT/PROP SEA LEVEL TO 48/57 48/57 54/62 34/51 2000 FT. 2000 FT.
– 10 – ECONOLINE SERVICE AND PARTS TR OUBLESHOO TING OVEN PROBLEM PROBABLE CAUSES Too much bottom heat. 1. Insufficient heat input. 2. Overactive flue. Uneven bake. 1. Too low temperture. 2. Improper operation. Side burning. 1. Improper bypass setting.
– 11 – ECONOLINE SERVICE AND PARTS REPLA CEMENT P ARTS LIST ECONOLINE GAS RESTAURANT RANGE REPLACEMENT PARTS LIST AND PHOTOS REPLACEMENT PARTS ORDERING The following information must accompany a replacements parts order or it cannot be filled. A. Model and style or serial number.
– 12 – ECONOLINE SERVICE AND PARTS PART NO. ITEM NO. DESCRIPTION 36L77R 60L77R 160L77R 260L77R 1 PILOT BRACKET 413302-1 413302-1 413302-1 413302-1 +2 REAR BURNER ASSEMBLY (NAT) 409643-G7 409643-G7.
– 13 – ECONOLINE SERVICE AND PARTS PART NO. ITEM NO. DESCRIPTION 36L77R 60L77R 160L77R 260L77R 6 BURNER VALVE HANDLE 413157-1 413157-1 14 LIGHTER VALVE 404193-2 404193-2 +15 BROILER BURNER VALVE (.
– 14 – ECONOLINE SERVICE AND PARTS PART NO. ITEM NO. DESCRIPTION 36L77R 60L77R 160L77R 260L77R 8 BRICK SET 407065-G1 407065-G1 407065-G1 14 PILOT VALVE (NS) 404193-2 404193-2 404193-2 18 THERMO. BULB - SHIELD (NS) 411655-2 411655-2 411655-2 19 THERMO.
– 15 – ECONOLINE SERVICE AND PARTS ITEM NO. DESCRIPTION PARTS NO. 36L77R 60L77R 160L77R 260L77R 92 RIGHT DOOR POST HANDLE 413416-1 1212 92A LEFT DOOR POST HANDLE 413416-2 1212 93 BELL CRANK PIN RS.
– 16 – ECONOLINE SERVICE AND PARTS PART NO. ITEM NO. DESCRIPTION 36L77R 60L77R 160L77R 260L77R +74 PILOT (NATURAL) 412787-1 412787-1 412787-1 412787-1 PILOT (PROPANE) 412787-2 412787-2 412787-2 41.
– 17 – ECONOLINE SERVICE AND PARTS PART NO. ITEM NO. DESCRIPTION 36L77R 60L77R 160L77R 260L77R 27 BELL CRANK 403956-1 403956-1 403956-1 403956-1 31 TURNBUCKLE & HOOKS 417865-1 417865-1 417865-.
– 18 – ECONOLINE SERVICE AND PARTS PART NO. ITEM NO. DESCRIPTION 36L77R 60L77R 160L77R 260L77R 33 SPLASHER BACK ASSEMBLY 413223-G1 413223-G3 413223-G3 413223-G5 SPLASHER BACK ASSEMBLY (SS) 413223-.
THIS P AGE INTENTIONALL Y LEFT BLANK.
THIS P AGE INTENTIONALL Y LEFT BLANK.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Vulcan-Hart 260L77R è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Vulcan-Hart 260L77R - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Vulcan-Hart 260L77R imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Vulcan-Hart 260L77R ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Vulcan-Hart 260L77R, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Vulcan-Hart 260L77R.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Vulcan-Hart 260L77R. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Vulcan-Hart 260L77R insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.