Manuale d’uso / di manutenzione del prodotto 56K del fabbricante Viking InterWorks
Vai alla pagina of 37
VIKING 56K USB MODEM (WINDOWS 95 (OSR2) & 98) USER’S GUIDE Manual No. 1005282 Release 03/99, Rev A SPEED • POWER • PERFORMANCE ®.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE Table of Contents 1 Introduction 56K External F eatures & Specifications 1 2 Before Y ou Install System Requir ements 2 Phone Requirements 3 Communi.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE 1 Introduction Congratulations on pur chasing your V iking Components 56K USB (Universal Serial Bus) fax/modem for your c omputer . T o turn y our computer into a commu- nications center , all you need is your Vik ing fax/modem and a standard analog phone line.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE 2 Before You Install It is recommended to read an y additional information in your system ’ s “ O wner ’ s Guide ” regarding external modems before continuing . S ystem Requiremen ts Computer: • Any comput er with a free USB por t.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE Phone Line Requirements The phone line required b y the Vik ing Components USB fax/modem is an analog RJ-11. This is a standard r esidential phone line. W arning: Do not use a PBX or digital phone line. These phone lines ma y damage the Vik ing C omponents USB fax/modem or phone equipment.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE 3 Installation This chapter contains instructions on installing your Vik ing 56K USB fax/modem. V erifying Y our S ystem is USB Ready Before installing the software f or your new V iking USB fax/modem, you will need to verify y our system is USB ready .
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE Hardwar e Installation W arning: The phone jack you use must be f or an analog phone line. If you ar e in an office building , it ma y use digital phone lines. If you are not sure of the type of phone lines your offic e building has, contact your phone system administr ator .
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE Hardwar e Installation (C ontinued) 2. Return the modem right side up and feed the phone cables through the back of its base. 3. Po wer on your comput er . 4. Locate an a vailable USB por t on your computer and c onnect it with the USB cable on the back of the modem.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE Sof tware Installa tion Once the V iking USB fax/modem is installed , you will need to install the software necessary to communicate with the fax/modem. This section will cover the steps necessary to configure your comput er ’ s operating system.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE Windo ws 95 (OSR2) Software (C ontinued) 4. Y ou will be asked to inser t the “ Viking USB Modem Installation Disk .” In the “ Copy F iles Fr om ” field , type: A: and then click on the “ OK ” button.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE Windo ws 98 Software 1. Y ou will be prompted with the “ New Hardware F ound ” message. Then “ Add New Hardware Wizard ” window will appear . A message in the window will r ead “ This wizard searches for new driv ers for : V .
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE Windo ws 98 Software (C ontinued) 3. The next message that should appear in the “ Add New Hard ware Wizard ”i s “ Windows will search for new drivers in its driv er database on your hard drive , and in any of the following selected locations .
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE Windo ws 98 Software (C ontinued) 5. The final message in the “ Add New Hardw are Wizar d ” should show your new Vik ing modem “ Viking USB Modem Board ” at the top . A message “ Windows has fin- ished installing the software that your new hardware devic e requires ” should also appear .
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE Using Da ta and F ax C ommunication Software Most communication software installation programs will automatically det ect your Vik ing fax/modem and preform the appropriate c onfigurations.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE 4 Technical Notes This chapter co vers the definitions of the status lights on the front of y our exter- nal modem, the COM port and IRQ settings, and information necessary when the system does not automatically configur e the fax/modem properly .
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE IRQ Settings and DOS Applications The Interrupt Resourc e (IRQ) assigned to the V iking 56K USB modem may not match the interrupt that DOS applications should be configur ed to use. They can be corrected by completing the f ollowing steps: 1.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE IRQ Settings and DOS Applications (C ontinued) 6. Selec t the “ DOS Support ” tab . 7. With your mouse , click on the checkbox “ Enable DOS Support . ” Then click on the “ OK ” button. Y ou will be asked to restart your system to activat e the changes.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE 5 Troubleshooting This chapter will co ver some solutions to some common pr oblems you may expe- rience when installing your Vik ing USB modem. Some solutions may not apply to your operating syst em or may not be listed .
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE General T roubleshooting Chapter 5 17 Problem The power light on the modem is not on. Modem does not respond , modem communication error or modem not found . Solution • Ensure the modem is plugged into your syst em’ s USB port.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE General (C ontinued) Chapter 5 18 Problem How can I change the speak er vol- ume on the modem? Modem does not dial or dials incor- rectly .
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE General (C ontinued) Chapter 5 19 Problem Modem does not fax No Dial T one message Solution • Did you select the correct fax class? Check your soft- ware , select another fax class and tr y again. • Do you hav e another communications program open? If so , close it.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE 6 Basic AT Commands F rom terminal mode or command line , A T commands allow you to c ontrol your modem. I f you are using y our communications software to operate y our modem, the software menus configure the A T commands.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE Basic A T Command Set (C ontinued) C ommand Function I3 Report firmware revision, model, and inter face type. I4 Report response programmed by an OEM. I5 Report the countr y code parameter . I6 Report modem data pump model and code revision.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE Basic A T Command Set (C ontinued) C ommand Function X1 Repor t basic call progress result codes and c onnections speeds (OK, CON NECT , RING, NO CARRIER (also, for busy , if enabled, and dial tone detected), NO ANSWER, C ONNECT XXXX, and ERROR.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE Basic A T Command Set (C ontinued) C ommand Function &G0 Disable guard tone. &G1 Disable guard tone. &G2 Enable 1800 Hz tone. &J0 Set S-Register r esponse only for compatibility . &J1 Set S-Register r esponse only for compatibility .
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE Basic A T Command Set (C ontinued) C ommand Function &T1 Initiate local analog loopback. &T2 Returns ERROR result code . &T3 Initiate local digital loopback. &T4 Allow remot e digital loopback.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE Basic A T Command Set (C ontinued) C ommand Function When modem receives br eak from the remote modem: K0,1 Clear data buffers and send break to DTE. K2,3 Send a break immediately to DTE. K4,5 Send a break with received data t o the DTE.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE EC C C ommands C ommand Function %C0 Disable data compression. %C1 Enable MNP 5 data compression. %C2 Enable V .42 bis data compression. %C3 Enable both V .42 and MNP 5 compression. A0 Set maximum block size in MNP to 64.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE MNP 10 C ommands (Continued) C ommand Function @M0 Select initial transmit level of -26 dBm. @M1 Select initial transmit level of -30 dBm. @M2 Select initial transmit level of -10 dBm. @M3 - @M10 Select initial transmit level of -10 dBm.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE F ax Class 1 C ommand Function +FCLASS=n Ser vice class. +F AE=n Data/fax auto answer . +FRH=n Receive data with HDL C framing. +FRM=n Receive data. +FRS=n Receive silence. +FTH=n T ransmit data with HDL C framing.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE F ax Class 2 (C ontinued) C ommand Function +FET=N T ransmit page punctuation. +FHNG Call termination with status. +FK Session termination. +FLID= Local ID string . +FLPL Document for polling. +FMDL? Identify model.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE 7 Modem Driver & Firmware Upgrades Y our Viking Ex ternal modem can be upgraded b y updating its drivers and through firmware upgrades . These upgrades can be downloaded from Vik ing Components W eb page at: http://www .
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE 8 Contacting Technical Support If your questions hav e not been answered or if y ou are unable to solve a problem with your modem by using this guide , Vik ing Components has T echnical Support av ailable 7 days a week and 24 hours a da y .
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE 9 Communication Regulations INDUSTR Y CANADA (IC) NO TICE “NO TICE: The Industry Canada (IC) label identifies certified equipment.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE P ART 68 REQUIREMENT S This equipment complies with P ar t 68 of the FCC Rules. On this equipment there is a label that contains, among other information, the FCC Registration Number and Ringer Equivalence Number (REN) f or this equipment.
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE P ART 68 REQUIREMENT S (C ontinued) This equipment may not be used on c oin ser vice provided by the t elephone com- pany .
VIKING C OMPONENTS 56K USB MODEM USER’S GUIDE 10 Warranty & Disclaimers 5 YEAR W ARR ANT Y All Vik ing C omponents products hav e been thoroughly tested free of defects in material and workmanship .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Viking InterWorks 56K è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Viking InterWorks 56K - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Viking InterWorks 56K imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Viking InterWorks 56K ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Viking InterWorks 56K, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Viking InterWorks 56K.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Viking InterWorks 56K. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Viking InterWorks 56K insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.