Manuale d’uso / di manutenzione del prodotto VEGCT424F del fabbricante Verona
Vai alla pagina of 20
✓ Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. ✓ WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
2 Dear Customer , Thank you for having pur chased and given your pr efer ence to our pr oduct. The safety pr ecautions and r ecommendations r eported below are for your own safety and that of others. They will also pr ovide a means by which to make full use of the featur es offer ed by your appliance.
3 IMPORT ANT PRECAUTIONS AND RECOMMENDA TIONS ✓ After having unpacked the appliance, check to ensure that it is not damaged. If you have any doubts, do not use it and consult your supplier or a professionally qualified technician. ✓ Packing elements (i.
4 COOKING POINTS 1. Auxiliary burner (AUX) - 3.500 BTU/hr 2. Semirapid burner (SR) - 6.000 BTU/hr 3. T riple ring bur ner (TC) - 11.500 BTU/hr CONTROL P ANEL DESCRIPTION 4. Auxiliary burner (AUX) control knob (1) 5. Right semirapid burner (SR) control knob (2) 6.
5 CHOICE OF BURNER (fig. 2.3) The symbols printed on the panel beside the gas knobs indicate the correspondence between the knob and the burner . The most suitable burner is to be chosen according to the diameter and volume capac- ity of the container to be warmed.
6 Do not use steam jet cleaners because the humidity could infiltrate into the appliance making it dangerous. GENERAL RECOMANDA TION ✓ Before you begin cleaning you must ensur e that the hob is switched off. It is advisable to clean when the appliance is cold.
7 CORRECT REPLACEMENT OF THE BURNERS It is very important to check that the burner flame spreader “ F ” and the cap “ C ” have been correctly positioned (see figs. 3.1 and 3.2 ). Failure to do so can cause serious problems. In appliances with electric ignition, check that the electrode “ S ” (fig.
8 W ARNING! THIS APPLIANCE HAS TO BE INST ALLED BY A QUALIFIED INST ALLER. Improper installation, adjustment, alteration, services, or maintenance can cause injury or pr operty damage. Consult a qualified installer , service agent, or the gas supplier .
9 GENERAL INFORMA TION 1. Installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code , ANSI Z223.1-Latest Edition.
10 installation to the cabinet min 22” 7/16 (570 mm) 30” (762 mm) 18” (457 mm) min 4” (102 mm) from cut-out max 13” (330 mm) 30” (762 mm) min 20” (508 mm) from cut-out max 13” (330 m m) 18” (457 mm) min 22” 7/16 (570 mm) Fig. 4.
11 20 mm min. 40 mm max. B C A Fig. 4.3 Fig. 4.4 F ASTENING THE COOKTOP (fig. 4.3 - 4.4) ✓ Each cooker top is provided with an installation kit including brackets and screws for fastening the top to fixtur e panels from 2 to 4 cm thick.
Gas supply line Shutoff valve “open” position To cooktop Fig. 5.1 12 All gas connections must be made according to national and local codes. This gas supply (service) line must be the same size or greater than the inlet line of the appliance. Sealant on all pipe joints must be resistant to te action of LP/Pr opane gas.
13 PRESSURE REGULA TOR INST ALLA TION To cooktop UNLOCK LOCK LOCK To cooktop LOCK Arrow STEP 1 The elbow connection can be turned in the direction requir ed after the manifold female pipe fitting has been slackened by using a wrench.
14 To mains connection To cooktop Manifold test point pressure 1/8” NPT 1/2” G cylindrical (ISO 228-1) male Cooktop manifold Manifold female pipe fitting Elbow connection Connector Pressure re.
15 b) Any conversion requir ed must be performed by your dealer or a qualified licensed plumber or gas service company . Please pr ovide the service person with this manual before work is started on the cooktop. (Gas conversions ar e the r esponsibility of the dealer or end user .
16 1 2 NATURAL GAS REGULATION LP/PROPANE REGULATION A SETTING THE PRESSURE REGULA TOR (fig. 5.5) 1. Unscrew the r egulator cover; 2. Unscrew the A component, r everse and screw it according to the LP/PROP ANE r egulation. CONVERSION TO LP/PROP ANE GAS Every cooktop is provided with a set of injectors for the various types of gas.
17 REGULA TING THE BURNER MINIMUM SETTING When switching from one type of gas to another , the minimum flow rate must also be correct: the flame should not go out even when passing suddenly fr om maximum to minimum flame. The adjustment is performed with the burner lit, as follows: –T urn the knob to the minimum position.
18 If codes permit and a separate ground wir e is used, it is recommended that a qualified electrician determine that the ground path is adequate. Check with a qualified electrician if you are not sur e whether the cooktop is prop- erly grounded. Do Not ground to a gas pipe.
19 Wiring diagram key A Ignition coil PA Ignition switches group M Te r m inal block CA Igniter Fig. 6.2 A NL PA M CA CA CA CA WIRING DIAGRAM .
Cod. 1103614-ß1 The manufacturer cannot be held r esponsible for possible inaccuracies due to printing or transcription errors in the present booklet.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Verona VEGCT424F è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Verona VEGCT424F - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Verona VEGCT424F imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Verona VEGCT424F ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Verona VEGCT424F, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Verona VEGCT424F.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Verona VEGCT424F. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Verona VEGCT424F insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.