Manuale d’uso / di manutenzione del prodotto VCPV30TP - 30 del fabbricante Vermont Casting
Vai alla pagina of 16
1 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater VERMONT C astings Models: VCBV30TN, VCBV30TP - 30,000 Btu/Hr Thermostat VCBV20TN, VCBV20TP - 20,000 Btu/Hr Thermostat VCBV10TN, VCBV10TP - 10,000 Btu/Hr Thermostat Blue Flame Heaters Unvented Gas-Fired Room Heater Please read this manual before installing and using appliance.
2 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater SAFETY : Accidents are always tragic, especially because so many of them could have been prevented with a little care and judgment. There are some basic good practices we hope you will follow for safe use of your gas fired room heater .
3 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater VCBVTN, VCBVTP , VCPVTN and VCPVTP Specifications NOTES: For altitudes above 2,000 feet, reduce the input ratings (Btu/Hr) 4% for each 1,000 feet above sea level. DO NOT USE THIS HEA TER A T AN ELEV A TION ABOVE 4,500 FEET .
4 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Installation Installation Requirements Fresh Air for Combustion and V entilation W ARNING: This heater must have fresh air for proper opera- tion.
5 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. *Aftermarket: Completion of sale, not for purpose of resale from manufacturer .
6 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Connect to Gas Supply Before connecting the appliance, turn of all gas appli- ances. Close the main gas valve at the gas meter or Lp tank. Make certain there is good ventilation where the installation will be made.
7 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Pressure Regulator 3/8” NPT Nipple T ee Joint Reducer Bushing to 1/8” NPT 1/8” NPT Plug T ab Heater Cabinet Ground Joint Union Manual Shutt-Off V alve From Gas Meter T est Gauge Connection T ee Joint Pipe Nipple Cap Sediment T rap Natural Gas (4” w .
8 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Lighting Instructions 1. Read the safety information. 2. Make sure manual shut-off valve is fully open. 3. Push in gas control knob slightly and turn clockwise to the OFF position. 4. W AIT 5 MINUTES TO CLEAR OUT ANY GAS.
9 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Pilot and Burner Inspection Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figures 9, 10 and 1 1. If flame patterns are incorrect, turn the heater off.
10 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Problem When control knob is pressed in and turned counterclockwise to ignition, there is no spark at ODS pilot. When control knob is pressed in and turned counterclockwise to ignition/pilot position, there is spark but no ignition.
11 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater T roubleshooting, continued Problem Possible Cause Solution Heater produces a clicking noise just after burner is lit or turned off. Gas odor even when control knob is in OFF position. Gas odor during combustion.
12 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater The V ermont Castings Majestic Products Company reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 3771 VCBVTN/ TP Unvented Room Heater 1.
13 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Item / Model Number VCBV10TN/TP VCBV20TN/TP VCBV30TN/TP VCBVTN/ TP , continued 20. Fix Nut - Nozzle Holder RBM08XX0 RBM08XX0 RBM08XX0 21a. Main Nozzle - Natural RBM07XEO RBM07XA0 RBM07XC0 21b. Main Nozzle - LP RBM07XF0 RBM07XB0 RBM07XD0 22a.
14 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater The V ermont Castings Majestic Products Company reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
15 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Contact V ermont Castings, Majestic Products with questions concerning prices and policies covering replacement parts. Parts may be ordered through you V ermont Castings distributor or dealer .
16 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater © V ermont Castings, Majestic Products W arranty Service and Limited W arranty The V ermont Castings Majestic Products Company warrants this .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Vermont Casting VCPV30TP - 30 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Vermont Casting VCPV30TP - 30 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Vermont Casting VCPV30TP - 30 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Vermont Casting VCPV30TP - 30 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Vermont Casting VCPV30TP - 30, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Vermont Casting VCPV30TP - 30.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Vermont Casting VCPV30TP - 30. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Vermont Casting VCPV30TP - 30 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.