Homeowner ’ s Installation and Operating Manual For use in the United States and Canada Do Not Discard This Manual: Retain for Future Use 30001693 1/07 Rev . 17 SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERL Y INST ALLED, OPERA TED AND MAINT AINED, A HOUSE FIRE MA Y RESUL T .
2 Defiant W oodbur ning Stove 30001693 This manual describes the installation, operation, and maintenance of the V ermont Castings Defiant Model 1945 cata- lytic-equipped wood burning heater . This heater meets the U.S. Environmental Protection Agency’s emission limits for wood heaters sold on or after July 1, 1990.
3 Defiant W oodbur ning Stove 30001693 T able of Contents Specifications ................................................. 4 Installation ...................................................... 5 Clearance Charts ......................................
4 Defiant W oodbur ning Stove 30001693 Specifications Defiant, Model 1945 EP A Emissions rating ....................................... .8 GPH* Range of heat output ...........10,600 to 44,400 Btu’s/hr .* Maximum heat output ......................
5 Defiant W oodbur ning Stove 30001693 Installation SAFETY NOTICE: IF YOUR DEFIANT IS NOT PROP- ERL Y INST ALLED, A HOUSE FIRE MA Y RESUL T . TO REDUCE THE RISK OF FIRE, FOLLOW THE INST ALLA TION INSTRUCTIONS. CONT ACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRIC- TIONS AND INST ALLA TION INSPECTION REQUIRE- MENTS IN YOUR AREA.
6 Defiant W oodbur ning Stove 30001693 What Kind of Chimney to Use Y ou must connect the Defiant to a code-approved masonry chimney with a flue liner , to a relined masonry chimney that meets local .
7 Defiant W oodbur ning Stove 30001693 • Fasten the chimney connector to the chimney . Instructions for various installations follow . Figure 5 illustrates the general layout of chimney connector parts. • Be sure the installed stove and chimney connector are correct distances from nearby combustible mate- rials.
8 Defiant W oodbur ning Stove 30001693 Without a thimble, a suitable length of chimney con- nector can be extended through the breech to the inner face of the flue liner , and cemented securely in place. Additional pieces of connector are then attached with sheet metal screws.
9 Defiant W oodbur ning Stove 30001693 ST245 fireplace flex connector 12/99 Flexible Connector Mantel Shield Fireplace Adapter Kit “Positive Connection” ST245 Fig. 9 Through the fireplace installation. D E F I A N ST493 Brick pass thru 1 1/00 W all Stud Chimney Connector Floor Protec- tion 12” of Noncombustible Material ST493 Fig.
10 Defiant W oodbur ning Stove 30001693 D E F I A N T ST494 steel wall pass thru 1 1/00 18” (460mm) clear- ance between pipe and sides/top/bottom of opening ST494 Fig. 1 1 An approved wall pass-through for Canada. D E A B A E C ST500 Defiant floor protection 1/31/02 djt E F E F U.
1 1 Defiant W oodbur ning Stove 30001693 For all fireplace installations, follow the floor protec- tion guidelines described above. Keep in mind that many raised hearths will extend less than the required clearance from the front of the heater .
12 Defiant W oodbur ning Stove 30001693 Fireplace and Mantel T rim Shields A fireplace installation requires special clearance between the side of the stove and the right and left walls, between the side of the stove and the decorative side trim on the fireplace face, and between the top of the stove and the mantel.
13 Defiant W oodbur ning Stove 30001693 Defiant Clearance Chart for use with either a 6” or 8” chimney connection Stove Clearance Stove Installed Parallel to W all Unprotected Surfaces Protected .
14 Defiant W oodbur ning Stove 30001693 D E F F C C J K L L I ST486a Defiant Clearance Diagrams 1 1/00 A B I G H P Q R R O O M N V W X X U S U T AA BB Y Z N/A N/A T op Exit Installations, no heat shie.
15 Defiant W oodbur ning Stove 30001693 48" (1220mm) 48" (1220mm) 48" (1220mm) ST498 Defiant Wall shield B 1 1/00 Fig. 17 Parallel installation with rear wall pass-through, two wall shields. Reduced clearances to both rear and side walls.
16 Defiant W oodbur ning Stove 30001693 Distance from the Center of the Flue Collar to the W all The information on this page is helpful in planning stove placement, particularly in those installations with chimneys that pass through the ceiling. However , this is not a clearance chart.
17 Defiant W oodbur ning Stove 30001693 Set Up Y our Stove Cast iron stoves are heavy , and it will take two to four people to move your Defiant into position. Wipe the protective coating of oil from the griddle with a clean dry rag or a paper towel.
18 Defiant W oodbur ning Stove 30001693 Install the Optional Ash Door Heat Shield 1. Remove the two Phillips pan head screws from the ash door . 2. Insert the screws through the ash door heat shield (from the painted side), place the 5/16” spacers over the screws, and carefully thread them back into the original holes.
19 Defiant W oodbur ning Stove 30001693 A Damper Directs Air Flow Within the Stove The damper handle on the left side of the stove oper- ates the damper to direct air flow within the stove. The damper is open when the handle points to the rear , enabling smoke to pass directly into the chimney .
20 Defiant W oodbur ning Stove 30001693 ST544 door open 11/00 Clockwise to Open Counter- clockwise to Close ST544 Fig. 31 T o open the front doors, turn the handle clockwise. T o reduce the risk of breaking the glass, avoid striking the glass or slamming the doors.
21 Defiant W oodbur ning Stove 30001693 Most installations do not require a large amount of combustion air , especially if adequate draft is available. Do not for any reason attempt to increase the firing of your heater by altering the air control adjustment range outlined in these directions.
22 Defiant W oodbur ning Stove 30001693 Never kindle a fire with colored paper or paper that has colored ink or a glossy surface, and never burn treated wood, garbage, solvents, or trash. All of these may poison the catalyst and prevent it from operating properly .
23 Defiant W oodbur ning Stove 30001693 ST264 good fire 12/99 ST264 Fig. 34 Add larger pieces of wood as the fire begins to burn well. ST264a add wood fire 11/00 ST264a Fig. 35 Add full size logs after the ember bed is 3” (75mm) deep. 4.
24 Defiant W oodbur ning Stove 30001693 located below and behind the throat, can glow at high temperatures. This is also normal. However , the ele- ment can be active and operate properly without glow- ing. The lack of a glow does not indicate that the cata- lyst isn’t working.
25 Defiant W oodbur ning Stove 30001693 A stove is part of a system, which includes the chimney , the operator , the fuel, and the home. The other parts of the system will affect how well the stove works. When there is a good match between all the parts, the system works well.
26 Defiant W oodbur ning Stove 30001693 There should be no more than eight feet of single-wall stove pipe between the stove and a chimney; longer runs can cool the smoke enough to cause draft and creosote problems. With prefabricated chimney , bring it down to six to eight feet from the stove.
27 Defiant W oodbur ning Stove 30001693 Negative Pressure Good draft also depends on a supply of air to the stove; a chimney can’t pull in more air than is avail- able to it.
28 Defiant W oodbur ning Stove 30001693 Keep Y our Stove Looking New and Working Its Best Let the fire in the stove go out and allow the stove to cool completely before beginning any maintenance procedure. Care of the Cast Iron Surface An occasional dusting with a dry rag will keep the painted cast iron of your Defiant looking new .
29 Defiant W oodbur ning Stove 30001693 Check the Operation of the Primary Air Shutter The primary air shutter is at the back of the ash drop and is visible from the back of the stove. (Fig. 39) The shutter must open and close freely when you move the thermostat lever .
30 Defiant W oodbur ning Stove 30001693 T he Catalytic Element This wood heater contains a catalytic combustor , which needs periodic inspection and replacement for proper operation.
31 Defiant W oodbur ning Stove 30001693 St556 inspect catalytic element 2 11/00 Alignment Notches Left Wedge Brick Guide Brick Clip Bricks ST556 Fig. 43 Remove the bricks and the brick retainer . Right Wedge St557 inspect catalytic ele 3 11/00 Lower Fireback ST557 Fig.
32 Defiant W oodbur ning Stove 30001693 6. If the element is in good condition and clean, re-in - stall it in the stove and replace the refractory access cover . 7. Replace the fireback, the five bricks and their clip, the left and right wedges, and the throat.
33 Defiant W oodbur ning Stove 30001693 7. Press the gasketed part firmly against its normal mating surface to seat the gasket evenly in its chan- nel. Close and latch the door to do this, or tap other parts with the rubber mallet (or hammer/block of wood).
34 Defiant W oodbur ning Stove 30001693 Appendix: Catalytic Combustor In any chemical reaction, including the combustion process, there are certain conditions which must be met before the reaction can take place.
35 Defiant W oodbur ning Stove 30001693 Appendix: Chimney and Fireplace Hazards General - A. Improper chimney height. The top of the chimney must be at least 3 feet higher than the spot where it passes through or past the roof, or two feet higher than everything else within ten feet horizontally , whichever is higher .
36 Defiant W oodbur ning Stove 30001693 80 13 28 1 2 3 6 4 8 15 25 16 17 5 14 44 45 47 61 7 27 32 34 35 38 39 46 26 1 1 29 30 31 79 10 62 40 42 55 56 41 66 50 80 33 60 57 58 67 76 75 78 68 70 43 64 65.
37 Defiant W oodbur ning Stove 30001693 Defiant W oodburning Stove Model 1945 (continued) 9. Refractory Assy (Body only) 1602512 10. Catalytic Combustor (Boxed) 30001 152 1 1. Refractory Access Panel 160251 1 12. Thermostat Friction Spring 1201846 13.
38 Defiant W oodbur ning Stove 30001693 Defiant W oodburning Stove Model 1945 (continued) Shell Enamel Parts - Defiant Enamel Color T op Left Side Right Side Front Ashlip Leg Classic 30001582 300015.
39 Defiant W oodbur ning Stove 30001693 W arranty Limited 3 Y ear W arranty CFM Corporation warrants that this woodburning stove will be free of defects in material and workmanship for a period of thr.
© CFM Corporation 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www .cfmcorp.com CFM Corporation.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Vermont Casting 1945 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Vermont Casting 1945 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Vermont Casting 1945 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Vermont Casting 1945 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Vermont Casting 1945, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Vermont Casting 1945.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Vermont Casting 1945. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Vermont Casting 1945 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.