Manuale d’uso / di manutenzione del prodotto LASER-FUTURA- EXPO series AT STD/TOP - AT BASE del fabbricante Unigreen
Vai alla pagina of 40
USE AND MAINTENANCE MANU AL MISTBLO WERS T O WED MISTBLO WERS LASER - FUTURA - EXPO series A T STD/T OP - A T BASE Read this manual carefully bef ore use.
2 unigreen Summary 1 USING AND KEEPING THE USE AND MAINTENANCE MANU AL .................... 4 1. 1 COMPOSITION OF THE MANU AL ....................................................................................... 4 1.2 GU ARANTEE ....................
unigreen 3 6.2.3 ANTI-DRIFT NOZZLES ....................................................................................................... 2 0 6. 3 CALIBRA TING AXIAL F AN A TOMI SERS ..................................................................
4 unigreen Thank you for having chosen UNIGREEN. The product you purchased has been designed and built with the greatest attention to the safety of the oper ator and the environment, ne ver theless there are still some residual risks due to the nature of the product used.
unigreen 5 2 SAFETY REGULA TIONS AND RESIDU AL RISKS In relation to saf ety , the f ollowing ter ms will be used: Dangerous zones: any zone inside and/or near the machine where the presence of a person exposed constitutes a risk for the safety and health of the same person.
6 unigreen 2. 1 INTENDED USE The spra yer in this series is b uilt for agricultural use. The mater ials used are resistant to normal chemical products used in agricultural spraying (or herbicides) at the time of construction.
unigreen 7 Refer to the enclosed handbooks for the use and maintenance of the pump and pressure regulator and any accessories or motors. b) Please contact the agent in your zone, the nearest authorised workshop or UNIGREEN S.p.A. directly for any repairs the user feels they aren’t capable of performing alone.
8 unigreen 3. 2 NOISE LEVEL OF THE MA CHINE Use earmuffs to protect your ears when using the machine, below you will find the data on the maximum noise levels during work. Atomisers with axial fan rotor A COUSTIC PO WER LEVEL emitted by the machine with axial f an rotor : 113.
unigreen 9 4.2 PRELIMINAR Y CHECKS When you receiv e the machine, chec k that it is complete and no par ts are missing. If there are any damaged parts, info r m your local reseller or UNIGREEN directly in good time.
10 unigreen 4.4 TRA CT OR COUPLING = The tractor must be equipped with a 1”3/8 ASAE DIN 9611/A at 550 rpm power-takeoff capable of supplying the power necessary for operating the machine.
unigreen 11 4.5 CARD AN SHAFT In some models this is supplied on request. The cardan shaft must bear the CE mark. It must always have its own instructions that must be followed scrupulously and it should come with a cov er bearing the mar k, integrated in e very par t.
12 unigreen Before remo ving the cov er of the filter , make sure that the same is isolated from the tubing by unscrewing the relevant rear valve (FIG.
unigreen 13 Pressure regulators without a v olumetric valve (GCP3-w ay - GRH-R V A) Adjusting the maximum pressure valve = put main control A in the drain position (“OFF”). = loosen the hand wheel of maximum pressure valve B completely (anticlockwise).
14 unigreen 4. 10 FILLING THE T ANK The machines for defensive crop treatments, in consideration of the safety of persons, animals and the protection of the environment, must only be filled indirectly from open water courses and only by free-falling water from the waterworks.
unigreen 15 4. 12 MIXING The active principle can be mixed using the relevant stirrers before and during the treatment. Correct mixing and stirring is the basis of the correct distribution on the crops. W e recommend some useful accessor ies such as the premixer for powders and liquids (see the following paragraph).
16 unigreen 4. 13 W ASHING THE A T OMISER After every treatment, thoroughly clean the equipment, washing it with water inside and out. Dir ty equipment is v er y dangerous for people and in particular for children. Discharging the residues of washing in the environment without taking precautions is forbidden as this pollutes water courses.
unigreen 17 5 BLO WER GROUP All the mistblower s have a high speed fan r otor . Y ou must take great care and beware of the effects that this can provoke: such as the aspiration and projection of foreign bodies which, although of a small size, can be very dangerous especially for the eyes and face.
18 unigreen 5.4 AXIAL RO T OR Generally the new models of rotors are fitted with 7 vanes made of aluminium or nylon + fibreglass and the vanes have a variable inclination from 20° to 40° with step adjustment by 5° (in some cases there are drilled reference discs) FIG.
unigreen 19 5.6.4 OIL FEED FROM TRA CTOR (for hydraulic systems) Connect the delivery and discharge quick-fit coupling to the respective connections, respecting the direction of flow . The distributor inlet pipe is connected to the aluminium flow separator valve ne xt to the distr ib utor .
20 unigreen 6.2.2 LO W V OLUME CONICAL NOZZLES (150-500L/HA) Made of two ceramic pieces with colour-coded plastic inser ts, the y are available in various sizes identified by the colour (see table 3 page 34). They have been specifically designed to obtain a large number of small drops with strong turbulence e ven at low pressures (2-3 bar).
unigreen 21 6.4 CALIBRA TING CANNON A TOMISERS ( T ab les on pages 31-33 ) Atomisers with a cannon blower group are mainly intended for treating forest trees or other tall plants that it is impossible to drive into with the sprayer (for e xample tobacco or similar cultivations).
22 unigreen 8 MAINTENANCE All of the maintenance operations and repairs must be carried out with the machine and cardan shaft stopped and the tank and circuit clean of any residues of chemical products. The maintenance of the mistblower is essential for maintaining a high level of safety .
unigreen 23 from our reseller perform any repairs or contact a specialised workshop. During all of the repairs, in particular when welding, the machine and the circuit must be clean of any residues of chemical product. If the machine has to be lifted (for example to change a wheel) follow the instructions in point 4.
24 unigreen part description code single Ø18 non-drip jet for mistblower with diaphragm (1/4" mount) without nozzles 1224/0194F double Ø18 non-drip jet for mistblower with diaphragm (1/4" .
unigreen 25 T ABLES FOR CALIBRA TING MISTBLO WERS Ø500-600 CALIBRA TING T ABLE uni gr een s pa T a be lla e r og azio ne in L it ri/e t t a r o G r .Ve nt ola Ø5 0 0 - Ø6 0 0 8 ge t t i Lt .
26 unigreen T ABLES FOR CALIBRA TING MISTBLO WERS Ø600-650 CALIBRA TING T ABLE uni gr een s pa T a be lla e r og azio ne in L it ri/e t t ar o G r .Ve nt ola Ø 6 0 0 - Ø 6 5 0 10 ge t t i L t.
unigreen 27 T ABLES FOR CALIBRA TING MISTBLO WERS Ø700-750 CALIBRA TING T ABLE uni gr een s pa T ab el l a ero gaz i o ne i n L i tri / ettaro Gr. V ento l a Ø700-Ø750 12 getti Lt .
28 unigreen T ABLES FOR CALIBRA TING MISTBLO WERS Ø800 CALIBRA TING T ABLE unigreen s pa Ta be lla e ro ga zion e in L it r i/e t t a ro G r.Ve n t ola Ø 8 0 0 1 4 ge t t i Lt .
unigreen 29 T ABLES FOR CALIBRA TING MISTBLO WERS Ø900 CALIBRA TING T ABLE uni g reen s pa Tab el l a ero gaz i on e i n L i tri / ettaro Gr. V en tol a Ø900 16 getti Lt .
30 unigreen T ABLES FOR CALIBRA TING MISTBLOWERS Ø650 TGZ CALIBRA TING T ABLE T ABLES FOR CALIBRA TING MISTBLOWERS Ø800 TGZ uni gr een s pa Tabe l l a ero g a zion e in L it r i/et t a ro G r.
unigreen 31 T ABLES FOR CALIBRA TING CANNONS Ø450 CALIBRA TING T ABLE f or CANNONS Tabe ll a er ogaz i one i n Li t ri / e tt aro C a nnone Ø 450 2 g etti uni gr een s pa L t.
32 unigreen T ABLES FOR CALIBRA TING CANNONS Ø400 - 440 - 480 CALIBRA TING T ABLE for CANNONS Tabe l l a eroga z i one in Li tr i / et t aro C annone Ø4 40 - 480 6 getti + 2 l ateral i unigreen s pa Lt .
unigreen 33 T ABLES FOR CALIBRA TING CANNONS Ø400 - 440 - 480 CALIBRA TING T ABLE for CANNONS Tabe l l a eroga z i one in Li tr i / et t aro C a nnone Ø4 00 6 ge tt i Tes ta S nodat a unigreen s pa L t.
34 unigreen T ABLE OF DELIVER Y IN LITRES / MIN. MEDIUM AND HIGH V OLUME Ø18 CONICAL NOZZLES FOR A T OMISER Ø NOZZLE 0, 8 1, 0 1,2 1,5 1 ,8 2,0 Ø SLINGER 1, 0 1, 0 1 ,2 1, 5 1, 8 1,8 PRESSURE 10 ba.
unigreen 35 T ABLE OF DELIVER Y IN LITRES / MIN. OF THE CONICAL NOZZLES FOR MITRA SPRA Y GUN note: standard Ø2,5 nozzle DIAMETER NOZZLE Ø 1,0 Ø 1,2 Ø 1,5 Ø 1,8 Ø 2,0 Ø 2,3 Ø 2,5 Ø 3,0 PRESSUR.
36 unigreen T ABLE 7 T ABLE OF PROGRAMMED MAINTENANCE OPERA TION 8 h 50 h 300 h END OF SEASON Check the le vel and state of the oil 0 Check the accum ulator pressure 0 Check the suction (hoses , pipes.
unigreen 37 T AB.14B ALLO WED FITTINGS 20 04 T O WED AT O M ISER S EXPO T Y PE O F Pol y ethy le ne T ank MA CHINE EXPO T - AT BASE T ABL E 14 b 1100 T FI TTIN G AT 1 0 BASE Nomi nal c apac i ty ( L.
38 unigreen T AB.15B ALLO WED FITTINGS 2004 T O WED AT O MISERS PL T T YPE O F P oly et h y len e T a n k MA CHIN E LASER - F U T U R A - AT ST D /T O P TA BLE 15 b P1 1 P16 FITTIN G A T 11 ST D AT 1 6 ST D C apac ità nominale ( lt.) 60 0 600 8 00 8 00 1000 10 00 1000 1500 150 0 1 500 200 0 20 00 2000 FA N FA N Ø60 0 NY .
unigreen 39 T AB.16B ALLO WED FITTINGS 20 04 CA NNO N T O W ED A T OMIS . T Y PE O F Pol y ethy le ne T ank MA CHINE LA S ER-F UTURA "C" T ABL E 16 b AT C P6 P11 A T C6 A T C11 FI TTIN G Nominal c ap ac ity ( L.
Descriptions, indicative illustr ations, UNIGREEN S.P .A. reser v es the r ight to make v ariations or modifications without pr ior wa rning. via Rinaldi, 105 - Loc. Cavazzoli (Reggio Emilia) - ITALY Tel. +39 0522 369811 Fax. +39 0522 369898 e-mail: info@unigreen-spa.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Unigreen LASER-FUTURA- EXPO series AT STD/TOP - AT BASE è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Unigreen LASER-FUTURA- EXPO series AT STD/TOP - AT BASE - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Unigreen LASER-FUTURA- EXPO series AT STD/TOP - AT BASE imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Unigreen LASER-FUTURA- EXPO series AT STD/TOP - AT BASE ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Unigreen LASER-FUTURA- EXPO series AT STD/TOP - AT BASE, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Unigreen LASER-FUTURA- EXPO series AT STD/TOP - AT BASE.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Unigreen LASER-FUTURA- EXPO series AT STD/TOP - AT BASE. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Unigreen LASER-FUTURA- EXPO series AT STD/TOP - AT BASE insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.