Manuale d’uso / di manutenzione del prodotto DynaGST/1602G del fabbricante UNICOM Electric
Vai alla pagina of 17
16 Port 10/100/1000Base-T Gigabit Ethernet Switch with two SFP (mini) GBIC Slots DynaGST/1602G U SER’S M ANU AL PN: GEP-33216T.
Content 1. Introduction .............................................................. 1 Features ..................................................................... 2 Package Contents ...................................................... 3 2. Hardware Description .
.
1 1. Introduction Gigabit Ethernet over copper technology is a proven cost-effective way for network equipment to be upgraded from Fast Ethernet to Gigabit speeds. The need of expensive fiber optic cabling for Gigabit speeds is eliminated by using standard 4-pair Category 5e copper cabling.
2 Features Compatible with IEEE802.3 10Base-T, IEEE802.3u 100Base-TX, IEEE802.3z Gigabit fiber and IEEE802.3ab 1000Base-T 16 Port Gigabit switch with two Mini SFP GBIC ports Automatic MDIX for all ports 4K entry MAC address table 2Mbit Memory buffer IEEE802.
3 Package Contents DynaGST/1602G Gigabit Ethernet switch Power Cord Four Rubber Feet User Manual DynaGST/1602G Gigabit Ethernet switch Power Cord User Guide Rubber Feet Figure 1-1. Package Contents Compare the contents of your DynaGST/1602G Gigabit Ethernet switch package with the standard checklist above.
4 2. Hardware Description This Section describes the hardware of the DynaGST/1602G Gigabit Ethernet switch. The physical dimensions of the DynaGST/1602G Gigabit Ethernet switch is: 440 x 224 x 44 mm (.
5 [Note] When the Mini GBIC module is installed, the Mini GBIC (Gigabit fiber) ports ha ve higher priority than the Gigabit copper ports and supercede them. It doesn’t matter if the Gigabit copper port is connected before or after the Mini GBIC port is connected.
6 Figure 2-3. LED Indicators LED Status Description Green Power On Power Off Power is not connected Green Port is operating at 1000Mbps. 1000 Off No device attached or in 10/100Mbps mode Green Port is connecting with the device. Blinking Port is receiving or transmitting data.
7 Mini GBIC LED The two Mini GBIC ports have two LED indicators each – LNK and ACT. The following table provides descriptions of LED status. Figure 2-4. Mini GBIC Port LED Indicators LED Status Description Green Port is connecting with device. LNK Off No device attached.
8 3. Installation Set the Switch on a sufficiently large flat space with a power outlet nearby. The surface should be clean, smooth, level, and sturdy. Ensure there is enough clearance around the Switch to allow air circulation and the attachment of the power cord and cables.
9 4. Network Application This section provides you a sample of network topology in which the DynaGST/1602G is used. In general, the DynaGST/1602G Gigabit Ethernet switch is designed as a high-bandwidth backbone switch.
10 5. Troubleshooting The Switch can be easily monitored through panel indicators to assist in identifying problems. This section describes common problems you may encounter and where you can find possible solutions. Diagnosing LED Indicator If the Link indicator does not light up after connection, check whether the network interface (e.
11 Cabling RJ-45 ports: Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45 connections: 100m. of Category 3,4 or 5 cable for 10Mbps connections, 100m. of Category 5e cable for 100Mbps connections, or 100m. of 4-pair Category 5e copper cabling for 1000Mbps connection.
12 6. Technical Specification The following table provides the technical specification of the DynaGST/1602G Gigabit Ethernet switch. Standard IEEE802.3 10Base-T IEEE802.
13 LED System: Power Per RJ-45 port: 1000Mbps, Link/Activity, Full duplex/ collision Mini GBIC port: Link and Activity Power Supply Internal power supply, AC 100~240VAC, 50/60 Hz Power Consumption 60W.
908 Canada Court City of Industry , C A 91748 U.S.A. Phone: 626.964.7873 or 800.346.6668 F ax: 626.964.7880 www .unicomlink.com e-mail: info@unicomlink.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il UNICOM Electric DynaGST/1602G è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del UNICOM Electric DynaGST/1602G - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso UNICOM Electric DynaGST/1602G imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul UNICOM Electric DynaGST/1602G ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il UNICOM Electric DynaGST/1602G, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del UNICOM Electric DynaGST/1602G.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il UNICOM Electric DynaGST/1602G. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo UNICOM Electric DynaGST/1602G insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.