Service and Parts Manual Supplement For Model CLRCO2075 U-Line Cor poration U-Line Cor poration 8900 Nor th 55th Street PO Bo x 245040 Milwauk ee, WI 53223 Milwauk ee, WI 53224-9540 www .
INTRODUCTION 2 Design ■ Features ■ Performance INTRODUCTION Three generations of pride and quality manufacturing and design improvements are built into all U-Line products. The result: U-Line leads the market with innovative technology and superior craftsmanship.
INTRODUCTION 3 Design ■ Features ■ Performance SERIAL NUMBER FORMA T The serial number is divided into four segments. A typical serial number is 035497-03-0004. The first two digits of the first segment, 03, represents the year the unit was made. The next four digits of the first segment, 5497, represents the shop order number .
INTRODUCTION 4 Design ■ Features ■ Performance NOTES.
INTRODUCTION 5 Design ■ Features ■ Performance T ABLE OF CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Serial Number Format . . . . .
GENERAL INFORMA TION 6 Design ■ Features ■ Performance LIMITED W ARRANTY U-Line Corporation warrants each U-Line product to be free from defects in materials and workmanship for a period of one ye.
GENERAL INFORMA TION 7 Design ■ Features ■ Performance W ARRANTY CLAIMS PROCEDURE When submitting claims for warranty payment, please follow these guidelines. Y ou can use any form you would normally use to bill your customer (your own computer generated form, Narda, USA, etc.
8 Design ■ Features ■ Performance SAFETY PRECAUTIONS Do not attempt to service or repair the unit until you have read the entire procedure. Safety items through- out this manual are labeled with W arning or Caution.
9 Design ■ Features ■ Performance SER VICING ELECTRICAL SPECIFICA TIONS Compressor Pins To measure start winding resistance, measure across the C-S pins. To measure run winding resistance, measure across the C-R pins. These pins should never measure any resistance to ground.
10 Design ■ Features ■ Performance LEVELING AND INST ALLA TION REQUIREMENTS It is extremely important that the unit is level. If it is not level, the ice mold will not fill evenly . This can cause a reduction in ice rate, uneven sized cubes or water spilling into the storage area which will cause the ice in the bin to melt prematurely .
11 Design ■ Features ■ Performance GRA VITY DRAIN INST ALLA TION These guidelines must be followed when installing drain lines to prevent water from flowing back into the ice maker storage bin and potentially flowing onto the floor causing water damage: • Drain lines and fittings must have a 5/8" inside diameter .
12 Design ■ Features ■ Performance CONNECTING A DRAIN PUMP If a gravity drain connection is not available, U-Line strongly recommends the use of the U-Line P60 drain pump. If your CLRCO2075 is not equipped with a factory installed pump, a P60 drain pump is available through your Dealer , or direct from U-Line.
13 Design ■ Features ■ Performance SER VICING SELF-CLEANING CYCLE INSTRUCTIONS To maintain operational efficiency , clean unit every six months (depending on water conditions more or less frequent cleaning may be necessary).
14 Design ■ Features ■ Performance INTERIOR ST ORAGE BIN CLEANING 1. Disconnect power from the ice maker . 2. Remove any ice from the storage bin. 3. W ipe down the storage bin with a solution of non-abrasive mild soap or detergent and warm water .
15 Design ■ Features ■ Performance 6. When the initial three-minute fill cycle is complete, the unit will enter ice making and refrigeration mode (1) if the bin is empty or below the sensor .
16 Design ■ Features ■ Performance SEQUENCE OF OPERA TION Mode 1: Ice Making and Refrigeration ICE MAKER EVAPORATOR COMP - COMPRESSOR CONDENSER BYPASS VALVE (UPPER) VALVE (LOWER) REFRIGERATION REF.
17 Design ■ Features ■ Performance SER VICING Mode 2: Ice Making and No Refrigeration ICE MAKER EVAPORATOR COMP - COMPRESSOR CONDENSER BYPASS VALVE (UPPER) VALVE (LOWER) REFRIGERATION REFRIGERATOR.
18 Design ■ Features ■ Performance SER VICING Mode 3: Refrigeration and No Ice Making ICE MAKER EVAPORATOR COMP - COMPRESSOR CONDENSER BYPASS VALVE (UPPER) VALVE (LOWER) REFRIGERATION REFRIGERATOR.
19 Design ■ Features ■ Performance SER VICING Mode 4: Ice Harvest (No Refrigeration Possible) ICE MAKER EVAPORATOR COMP - COMPRESSOR CONDENSER BYPASS VALVE (UPPER) VALVE (LOWER) REFRIGERATION REFR.
20 Design ■ Features ■ Performance Mode 5: All Satisfied ICE MAKER EVAPORATOR COMP - COMPRESSOR CONDENSER BYPASS VALVE (UPPER) VALVE (LOWER) REFRIGERATION REFRIGERATOR EVAPORATOR CAPILLARY TUBE HO.
21 Design ■ Features ■ Performance Mode 6: Water Fill - No Refrigeration Required ICE MAKER EVAPORATOR COMP - COMPRESSOR CONDENSER BYPASS VALVE (UPPER) VALVE (LOWER) REFRIGERATION REFRIGERATOR EVA.
Design ■ Features ■ Performance Mode 7: Cleaning (No Refrigerator Possible) ICE MAKER EVAPORATOR COMP - COMPRESSOR CONDENSER BYPASS VALVE (UPPER) VALVE (LOWER) REFRIGERATION REFRIGERATOR EVAPORATO.
23 Design ■ Features ■ Performance SER VICING Mode 8: Water Fill with Refrigeration Required (Note: Normal Start-up with a warm refrigerator) ICE MAKER EVAPORATOR COMP - COMPRESSOR CONDENSER BYPAS.
24 Design ■ Features ■ Performance THERMIST ORS Condenser Thermistor The condenser thermistor senses the refrigeration system “high side” temperature. This is used in conjunc- tion with the control board to determine the length of the freeze and harvest cycles.
25 Design ■ Features ■ Performance CONTROLLER The temperature controller is located below the clear ice maker . It consists of an LED display , three LED status indicator lights and three touchpad buttons. The LED display shows the refrigerator temperature set point and is calibrated in degrees Fahrenheit.
26 Design ■ Features ■ Performance LED Status Meaning 1 Solid Refrigerator T emperature displayed Flashing Not Applicable 2 Solid Service Menu – wait 10 seconds and it will exit automatically Flashing Open thermistor – Refer to Thermistors.
Check Lights on Control Board The lights on the control board indicate power to the labeled component. The exception is the “REF VA L VE” (refrigeration valve). When this light is off, the refrigeration bypass valve is powered. 1. PWR 5. HOT GAS 2.
28 Design ■ Features ■ Performance Compressor COMP To ener gize the compressor touch the previously disconnected pink lead back to the board. Y ou should hear the compressor start up and the green COMP light will illuminate. If it does not start check voltage at the compressor and at the output from the board.
REFRIGERA TION SYSTEM DIAGNOSIS GUIDE System Suction Suction Compressor Condenser Capillary Evaporator W attage Condition Pressure Line Discharge T ube Normal Normal Slightly below V ery hot V ery hot.
30 Design ■ Features ■ Performance ICE THICKNESS ADJUSTMENT Y our U-Line Clear Ice Maker uses advanced technology to make ice that is crystal clear . This technology cascades a flow of water over a chilled ice mold that is mounted vertically so no water sits in it.
31 Design ■ Features ■ Performance 1. Disconnect power to the unit. Access Cover 2. Remove the screws securing the front access panel. Ice Thickness Adjustment Dial CLRCO031 0 1 2 -2 3 4 5 -5 -4 -.
32 Design ■ Features ■ Performance 3. Locate the ice cube thickness adjustment dial on the control board. T urn the dial clockwise (+ number) to thicken or counterclockwise (- number) to thin the ice bridge. Ice Cube Mold 4. Reinstall front access cover .
33 Design ■ Features ■ Performance SER VICING TROUBLESHOOTING 1 Not refrigerating (compressor and fan are operating) CAUSE REMEDY a. Little or no frost pattern on evaporator a. Check for sealed system leak or restriction 2 Not refrigerating (compressor not operating, fan operating) CAUSE REMEDY a.
34 Design ■ Features ■ Performance SER VICING 8 No ice production CAUSE REMEDY a. No water supplied to unit a. Check that water is connected and turned on b. Stand pipe not inserted in water trough b. Insert stand pipe securely into water trough 9 Low ice production CAUSE REMEDY a.
35 Design ■ Features ■ Performance SER VICING CLR2075 W iring Diagram CLRCO028 -1 -2 -3 -4 -5 5 4 3 2 1 0 WHITE GREEN RED BLACK RED BLACK WHITE GREEN THIS SIDE TO DISPLAY 10 9 8 7 6 5 4 3 2 1 Ther.
36 Design ■ Features ■ Performance SER VICING PA R TS LISTING How to Order Replacement Parts 1. Locate the illustration(s) for the model you are servicing. 2. Refer to the area where the desired part would be installed, locate the part and note the item number assigned to it.
37 Design ■ Features ■ Performance CLRCO2075 MODEL NOTES.
MODEL CLRCO2075 (1 OF 3) CLRCO032 2 3 4 5 6 10 11 12 13 14 15 16 17 18 22 23 24 25 26 27 7 1 8 21 20 19 9 38 Design ■ Features ■ Performance CLRCO2075 MODEL P ARTS.
39 Design ■ Features ■ Performance MODEL CLRCO2075 (1 OF 3) CLRCO2075 MODEL P ARTS Parts Not Shown Item Description White Black Stainless Steel 1 Door Assembly 80-17019-02 80-17019-01 See Parts No.
40 Design ■ Features ■ Performance CLRCO2075 MODEL P ARTS MODEL CLRCO2075 (2 OF 3) CLRCO033 16 1 15 17 18 19 20 21 22 23 2 3 4 5 6 7 8 9 10 11 12 13 14.
MODEL CLRCO2075 (2 OF 3) 41 Design ■ Features ■ Performance CLRCO2075 MODEL P ARTS Item Description White Black Stainless Steel 1 Cover - Front 12070-01 12070-01 12070-01 2 Evaporator Assembly 227.
42 Design ■ Features ■ Performance CLRCO2075 MODEL P ARTS MODEL CLRCO2075 (3 OF 3) CLRCO034 5 4 9 10 13 2 1 6 7 8 3 14 11 12.
43 Design ■ Features ■ Performance CLRCO2075 MODEL P ARTS Item Description White Black Stainless Steel 1 Heat Exchanger Assembly 72006-S 72006-S 72006-S 2 Back Panel 1 1969-02 1 1969-02 1 1969-02 .
44 Design ■ Features ■ Performance NOTES.
45 Design ■ Features ■ Performance NOTES.
46 Design ■ Features ■ Performance NOTES.
47 F AX P ARTS ORDER FORM F AX # 414-354-7905 Account# ____________________________________ Bill to: ______________________________________ ____________________________________________ _______________.
P .O. Box 245040 Milwaukee, WI 53224-9540 Phone 414.354.0300 F AX 414.354.7905 Printed in U.S .A. – A ugust 2003 ULIN 9332 P/N 30018.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il U-Line CLRCO2075 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del U-Line CLRCO2075 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso U-Line CLRCO2075 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul U-Line CLRCO2075 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il U-Line CLRCO2075, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del U-Line CLRCO2075.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il U-Line CLRCO2075. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo U-Line CLRCO2075 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.