Manuale d’uso / di manutenzione del prodotto SMT1000 del fabbricante TRENDnet
Vai alla pagina of 18
Oper at ion Ma nual Smart- UPS ™ Un inte rr upt i ble P o w er Sup p ly To w e r 750/1000/1 500/2200/3 000 V A 100/ 120 /23 0 V a c 500 V A 100 V a c.
.
1 Smar t- UPS 750/1 000/1500/ 220 0/3000 VA 100/120/ 230 Vac / 50 0 VA 100 Vac Tower Overv iew Produc t De scription The A PC ™ by Schneider Ele ctric Smart -UPS ™ i s a high per formance uninte rruptibl e power supply (UPS ).
Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/ 230 Vac / 500 VA 100 Vac Towe r 2 S pecifications For addi tional speci ficat ions, refer to the APC by Schnei der E lectric W eb si te a t www .
3 Smar t- UPS 750/1 000/1500/ 220 0/3000 VA 100/120/ 230 Vac / 50 0 VA 100 Vac Tower Prod uct Over view Front panel fea tures Rear p anel f eatu res 50 0 V A to 15 00 V A mod els 1 Di spla y inte rfac.
Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/ 230 Vac / 500 VA 100 Vac Towe r 4 Rear p anel f eatu res 22 00 V A and 3 000 V A mo dels Inst allat ion For UPS inst all ation inform at ion, refer to the Smart-UPS I ns tal lati on Guide 7 50/1000/ 1500/2200/ 3000 V A 100/120/ 230 V ac, 500 V A 100 V ac T ower, that i s incl uded with the UPS.
5 Smar t- UPS 750/1 000/1500/ 220 0/3000 VA 100/120/ 230 Vac / 50 0 VA 100 Vac Tower Operat ion Conn ect Eq uipm ent Note: The 2200/3000 V A 100 V ac model UPS wil l char ge to 9 0% capacity i n the fi rst four and a ha lf hours of norm al ope ra tion.
Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/ 230 Vac / 500 VA 100 Vac Towe r 6 Displa y Panel Usi ng th e dis p l ay in ter face Us e t he U P / D OWN arro w butto ns to s croll throug h the m ain men u opti ons. Pr ess ENTER to vi ew the submenus unde r each main menu optio n.
7 Smar t- UPS 750/1 000/1500/ 220 0/3000 VA 100/120/ 230 Vac / 50 0 VA 100 Vac Tower Ad van ced me nu s The Advan ce d men us provide additi onal opti ons f or the UPS and ar e availabl e only if the dis play int erfa ce i s configu red to use the Adva nced menus.
Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/ 230 Vac / 500 VA 100 Vac Towe r 8 Config uration UP S Sett ing s St a rt up Settings Configure the se se ttings at i nitia l st art up, usin g the dis play i nterface . As a n alt ernat ive, co nfigurat ion c an be perform ed using PowerChut e ™ software.
9 Smar t- UPS 750/1 000/1500/ 220 0/3000 VA 100/120/ 230 Vac / 50 0 VA 100 Vac Tower Low T ran sfer Poi nt 100 V ac: 92 V ac 86 V ac - 92 V ac Set the tr ans fe r po int lo we r if th e u tilit y vol ta ge is chr onical ly low an d the conn ect ed equipm en t can tole ra te t his c o ndi tion .
Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/ 230 Vac / 500 VA 100 Vac Towe r 10 Main Outlet Group and Controlle d Outle t Group Ov ervi ew The Main Outle t Group and the Control led Outle t Group can be configure d to inde penden tly turn of f, turn on, s hut down , and reboot conn ected equi pment.
11 Smar t-UPS 750/1000/ 1500/220 0/3000 VA 100/120/230 Vac / 500 VA 100 Vac Tower Cu stom iz e t he M a in and C ont roll ed Ou tl et G ro ups Us e t he Configuration menus to change t he Ma in Outlet Group and the Controll ed Outlet Group se tt ings.
Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/ 230 Vac / 500 VA 100 Vac Towe r 12 Emergen cy Power Of f Ov ervi ew The Emerge ncy Power Off (E P O) optio n, is a safety fe ature th at wil l immediate ly di s connect al l connecte d equipm ent f rom util ity power .
13 Smar t-UPS 750/1000/ 1500/220 0/3000 VA 100/120/230 Vac / 500 VA 100 Vac Tower T rou bleshoot ing Pr oblem and Po ssible Cause Solution The UPS w ill n o t turn on o r t here is n o ou tp ut The uni t has not b een tur ned on. Pre ss the O N key once to tur n on the UPS.
Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/ 230 Vac / 500 VA 100 Vac Towe r 14 Se rvice If th e un it re q ui re s se r vi ce , d o no t retur n it to t he d e al er . Fol lo w t he se st eps: 1. Review the T r ouble shooti ng se ction of t h e ma nual to e limin at e co m mon pr obl em s.
15 Smar t-UPS 750/1000/ 1500/220 0/3000 VA 100/120/230 Vac / 500 VA 100 Vac Tower T wo Y ear Limited Factor y W arr ant y Schneid er Electri c IT Corpora tion (SEIT ), war rants its pr oduc ts to be f.
03/20 13 EN 990- 3534 D APC by Schne ider Electric World wide Cust omer Support Customer suppor t for this or any othe r APC by Schneider Ele ctric product is avail able at no char ge in any of the fo.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il TRENDnet SMT1000 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del TRENDnet SMT1000 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso TRENDnet SMT1000 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul TRENDnet SMT1000 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il TRENDnet SMT1000, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del TRENDnet SMT1000.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il TRENDnet SMT1000. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo TRENDnet SMT1000 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.