Upflo w/Horizontal T w o-sta ge Condensing Gas-Fired Furnace XV 90 TUY060,080,100,120R9V V ariable Speed Blo wer V ariable Speed Inducer PUB. NO . 22-1682-05-0802 (EN) TDD-D-1.
2 Pub. No. 22-1682-05-0802 (EN) General Features © 2002 American Standard Inc. All Rights Reserved NA TURAL GAS MODELS Central heating furnace designs are cer tified b y the Inter national Approv al Services (IAS) for both natural and L.
3 Pub. No. 22-1682-05-0802 (EN) Contents Feature Summary Features and Benefits Standard Equipment Optional Equipment General Data TUY060R9V3V TUY080R9V3V TUY100R9V4V TUY120R9V5V P erformance Data Elec.
4 Pub. No. 22-1682-05-0802 (EN) XV 90 ST AND ARD EQUIPMENT Features and Benefits • Variable speed indoor blower • Silicon Nitride Igniter with adaptive heat up • Variable speed induced draft blo.
5 Pub. No. 22-1682-05-0802 (EN) Features and Benefits OPTIONAL EQUIPMENT Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling .......................................................................................... T A YS T A T241 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) .
6 Pub. No. 22-1682-05-0802 (EN) TUY-R9V PRODUCT SPECIFICA TIONS 1 MODEL RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE (ICS) T emp. Rise (Min.-Max.) °F . BLO WER DRIVE Dia.-Width (In.
7 Pub. No. 22-1682-05-0802 (EN) P erf ormance Data *UY060 R9V3V FUR NA CE COOLING AIRFL O W (CFM) AND PO WE R (W A TT S) VS. EX TERNAL ST A TIC PRESSUR E WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFL OW SETTI NG DIP SWITC H SETTING EXTERN AL ST A TIC PR ESSURE SW 1 SW 2 SW 3 SW 4 0.
8 Pub. No. 22-1682-05-0802 (EN) P erf ormance Data TUY080 R9V3V FUR NACE COOLING AIR FLOW (CFM) AND PO WE R (W A TTS) VS. EX TERNAL ST A TIC PR ESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS ) AIR FLOW SETT ING (See Notes) DIP SWI TCH SETTI NG EX TERNAL ST A TI C PRESSURE SW 1 SW 2 SW 3 SW 4 0.
9 Pub. No. 22-1682-05-0802 (EN) P erf ormance Data TUY100 R9V4V FUR NACE COOLING AIR FLOW (CFM) AND PO WE R (W A TTS) VS. EX TERNAL ST A TIC PR ESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS ) AIR FLOW SETT ING (See Notes) DIP SWI TCH SETTI NG EX TERNAL ST A TI C PRESSURE SW 1 SW 2 SW 3 SW 4 0.
10 Pub. No. 22-1682-05-0802 (EN) P erf ormance Data TUY120 R9V5V FUR NACE COOLING AIR FLOW (CFM) AND PO WE R (W A TTS) VS. EX TERNAL ST A TIC PR ESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS ) AIR FLOW SETT ING (See Notes) DIP SWI TCH SETTI NG EX TERNAL ST A TI C PRESSURE SW 1 SW 2 SW 3 SW 4 0.
11 Pub. No. 22-1682-05-0802 (EN) SCHEMA TIC DIAGRAMS FOR GAS FURNA CES TUY060,080,100,120R9V -V LEGEND Electrical Data From Dwg. 21D341111 P03.
12 Pub. No. 22-1682-05-0802 (EN) TO 115 V 1 PH., 60 HZ., POWER SUPPL Y PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 Field Wiring FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING F rom Dwg. 21B341127 Rev . 0 F rom Dwg. 21B341126 Rev . 0 FIELD WIRING DIA GRAM FOR 2 ST A GE HEA TING THERMOST A T TO 115 V 1 PH.
13 Pub. No. 22-1682-05-0802 (EN) Field Wiring FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) F rom Dwg.
14 Pub. No. 22-1682-05-0802 (EN) Field Wiring FIELD WIRING DIA GRAM FOR 2 ST A GE HEA TING TWO ST A GE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) F rom Dwg.
15 Pub. No. 22-1682-05-0802 (EN) Dimensions TUY-R9V -V OUTLINE DRA WING (ALL DIMENSIONS ARE IN INCHES).
Since T rane has a policy of continuous product improv ement, it reserves the right to change design and specifications without notice. T rane A business of American Standard Companies www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Trane XV 90 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Trane XV 90 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Trane XV 90 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Trane XV 90 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Trane XV 90, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Trane XV 90.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Trane XV 90. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Trane XV 90 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.