ALL phases of this installation must comply with NA TIONAL, ST A TE AND LOCAL CODES IMPOR T ANT — This Document is customer proper ty and is to remain with this unit. These instructions do not cover all v ar iations in systems or provide f or ev er y possible contingency to be met in connection with the installation.
2 18-HD64D1-1 2.1 Overview 2.2 Contents in Bo x 2.3 Specifications Specification Description Product Model: TZONE950AC52ZA Product: ComfortLink II Thermostat Size: 7.
18-HD64D1-1 3 2.4 ComfortLink II System Connections Thermostat TZONE950AC52ZA Thermostat TZONE950AC52ZA Outdoor Unit Indoor Unit Relay Panel BA Y24VRP AC52DA Relay Panel Outdoor Unit Indoor Unit Commu.
4 18-HD64D1-1 Thermostat TZONE950AC52ZA Thermostat TZONE950AC52ZA Outdoor Unit Indoor Unit Relay Panel BA Y24VRP AC52DA Relay Panel Outdoor Unit Indoor Unit Communicating System 24V System Wired Remot.
18-HD64D1-1 5 T emperature Sensing Considerations Wireless Reception Considerations Removing Sub-Base W all Plate The thermostat sensor is designed for installation in climate controlled living spaces. It is recom- mended to place the sensor in central locations with good circulation.
6 18-HD64D1-1 Mounting Sub-Base to Wall Be sure wires are routed through the center of the base plate and are long enough to connect to ter- minals. Select and mark three holes. NO TE: The three hole locations indicated at right are recommended. The top location is an optional mounting screw location.
18-HD64D1-1 7 CA UTION: EQUIPMENT D AMAGE HAZARD - Improper wiring can lead to equipment damage. F ollow the ter minal connection information care- fully to ensure the control is wired properly . After wires are secure, bare wires MUST NO T touch each other.
8 18-HD64D1-1 Red Brown Blue Red Brown Blue B D R 24V Single Stage Cooling B D R W1 W2 W3 G Y2 B O BK D Y1 R W1 W2 W3 G Y2 B O BK D Y1 R Ye llow Ye llow Blue Blue Brown Brown Blue Blue Thermostat Rela.
18-HD64D1-1 9 Communicating Equipment Discov er y mode begins when the ther mostat is first installed and power is connected. F or communicating equip- ment, the ther mostat automatically configures standard equipment parameters .
10 18-HD64D1-1 Enter the Installer’ s Setup screen by na vigating to: Home screen --> Menu --> Service --> T echnician Access --> Proceed* --> Installer Setup *NO TE: Press and hold the “T echnician Access” button f or 5 seconds to enter the Installer Setup screen.
18-HD64D1-1 11 Adv anced Equipment settings ma y be adjusted to alter the def ault settings to fine-tune a system’ s operation. Installed accessories and comfort options may be configured in the Adv anced screen. NO TE: Icons a vailable in this men u will v ar y based on equipment configuration.
12 18-HD64D1-1 CA UTION : “Restore Equipment Def aults” returns the thermostat to factory settings. ALL settings and data will be lost. “Reset Adv anced Settings” resets the Adv anced Settings which were configured in the Installer Menu (settings such as system lock outs, accessories, air flow and comf or t options).
18-HD64D1-1 13 Feature Description 1-T ouch Presets The 1-T ouch Presets allows for an immediate change to the setpoint status . Set the desired temper- ature f or the three status modes (Home, A wa y & Sleep). The ther mostat will remain in the selected mode until another mode is selected or the program reaches a ne w schedule per iod.
14 18-HD64D1-1 Feature Description Cycle Rate The cycle rate aff ects the cycle time of the system. With a 50% load value, a cycle rate of 3 will allow the system to run f or 10 minutes and be off f or 10 minutes; completing 3 cycles in one hour . A cycle rate of 5 would allo w the system to cycle on and off at 6 minute intervals.
18-HD64D1-1 15 Feature Description Histor y Screen The Histor y Screen provides system cycle inf or mation. Cycle counts and r un time can be view ed f or first stage and second stage compressor operation, W1 & W2 heating and defrost cycles . This inf or mation can be view ed in a 24 hour , 1 week or 2 week period.
16 18-HD64D1-1 Feature Description Runtime Histor y The Histor y Runtime screen provides inf or mation on system run time in compar ison to the indoor and outdoor temperatures (a ver age indoor along with the high & low outdoor temps). This histor y can be view ed on a weekly or monthly basis.
18-HD64D1-1 17 Section 7. T roub leshooting Symptom P ossible Causes Action Thermostat displays an aler t code on the screen. Aler t Code is present. Ref er to the Aler t Code Addendum. Check the Aler t icons in the diagnostic screen. Displa y will not come on Loss of 24V A C between R & B at the thermo- stat.
18 18-HD64D1-1 Standard Outdoor Unit T ype None Cooling Only Heat Pump Outdoor Unit Stages 1 2 Compressor T ype Single Compressor T wo Stage T wo Compressor T wo Stage Indoor Unit T ype Electric Gas/O.
18-HD64D1-1 19 W ar m Air Discharge Disab le Enable Airflow VS Blower On Dela y - Cooling No Delay 1 Minute @ 50%, 7.5 Minutes @ 80% 1 Minute @ 50%, 4 Minutes @ 80% 7.5 Minutes @ 80% 4 Minutes @ 80% 1 Minute @ 50% 30 Seconds @ 35% VS Blower Off Dela y - Cooling No Delay 1.
The manufacturer has a policy of contin uous product and product data improve- ment and it reserves the right to change design and specifications without notice.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Trane 18-HD64D1-1 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Trane 18-HD64D1-1 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Trane 18-HD64D1-1 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Trane 18-HD64D1-1 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Trane 18-HD64D1-1, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Trane 18-HD64D1-1.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Trane 18-HD64D1-1. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Trane 18-HD64D1-1 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.