ENGLISH EN AIR CONDITIONER (SPLIT TYPE) O WNER’S MANU AL For general pu blic use Indoor Unit Outdoor Unit RAS-07PKVP-E RAS-10PKVP-E RAS-13PKVP-E RAS-16PKVP-E RAS-18PKVP-E RAS-07PKVP-ND RAS-10PKVP-ND.
i ACCESSORIES ........... ................. ..................... ..................... ........ 1 PRECAUTION FOR SAFETY .............. .... ..... .... ................. .... ........ 1 NAMES OF PARTS ...................... ..................... .....
1 EN Store this owner’s manual in a location where it can be easily a ccessed when needed. Be sure to read this owne r’ s ma nual care f ully bef ore oper ating. The supplied CD- ROM co ntains the o wner’ s manual tran slated into man y langu ages.
2 EN Do not select a location f or in stallation wher e flammab le gas ma y l eak. If there is any gas lea kage or accu mulation around the unit, it ca n be a cause o f f ire. Do not select a location f or in stallation wher e there ma y be e xce ssiv e water or humidity , suc h as a bathroo m.
3 EN Stand on a st urdy ladder when a ttaching/detach ing the front pan el/air filter/air cle aning filter . F ailure to do so may cause a fall or injury . Do not stand on the outdoor unit or place anything on the unit. It may be the cause of injur y due to fallin g or ov er-turning.
4 EN Outdoor unit a Refrigerant co nnecting pipe, electr ic wires an d drain hose b Air inlet c Air outlet Indoor unit d Humidity senso r/temperature sens or e F ront panel f Moving panel g Air filter.
5 EN REMO TE CONTROLLER AND ITS FUNCTIONS a Infrared si gnal tran smitter T ransmits signal s to the indoor un it. b but to n Press the button to star t operation. (A receivin g beep is heard.) Press the button again to stop operation. (A receiving beep is heard.
6 EN Display All indicators, except f or the clock time indicator, are display ed by pressing the button. a T ran smission mar k This tran smission mark ( ) indicates when th e r emote controlle r transmits signals to the indoor unit. b Mode indic at or Indicates the current o peratio n mo de.
7 EN Loading the remote co ntrolle r ba tte ries a Remove the co ver , and insert the batteries. b Reattac h the co ver . Removing the batteri es a Remove the cover , and take out the batteries. b Reattac h the co ver . * Please dispose of the batter ies accord ing to the local regulation.
8 EN Adjusting the cloc k a CLOCK button Press the CLOCK button. The clock time indicator flashes. b ON button (o r OFF b utto n) Press the ON button (or OFF button) to set the current tim e. Each press of th e ON button (or OFF button) changes the time in one minute incremen ts.
9 EN Location of the remote controller • Keep the remote controller wh ere its signals can reach t he receiver of the indo or unit (a distance of up to 7 m is allo wed). • When yo u select timer operati on, the remot e controller au tomatically t ransmit s a signal to the in door unit a t the specified tim e.
10 EN When you set the air conditioner to A UT O mode, it auto matically se lects cooling, he ating, or fan only operation depending on th e room temperature. ( ) see pa ge 19.) The fan speed and louver are also au tomatically contr olled. Start a but to n Press this button to star t th e air conditione r .
11 EN Start a but to n Press this button to star t th e air conditione r . b Mode select button (MODE) Select COOL or HEA T . c T emperature button ( ) Set the desired temperature. d Fan sp eed but ton (F AN) Select one of “AUT O” LO W , LOW+ , MED , MED+ , HIGH .
12 EN This function is usable f or prev ention of freeze of an uninhabited room . Press this b utton to start the 8°C set temper ature heat ing opera tion.
13 EN Press this b utton to start the electrical air purifying o peration . During air condition er operation a PURE button PURE operation star ts by pressin g this button. • The PURE indica tor (blue) on the display panel of the indo or unit tur ns on.
14 EN ON timer and OFF timer Setting the ON Timer a ON button Press the ON button. Set the timer to the desire d time. Each time the ON button is pressed, th e time changes in ten minute increm ents. Holding down the ON bu t ton changes the t ime in one hour inc rements .
15 EN Combined timer (Setting the ON and OFF timer s sim ultan eously ) OFF timer —> ON timer (Operation —> Stop —> Ope ra t io n) This feature is useful when you want to stop the air conditioner aft er you go to sleep, and star t it again in the morn ing when yo u wak e up or y ou return home .
16 EN Use the MEMO b utton t o store a freq uently used op eration se tting f or con v enience . Start the air conditioner in th e operat ion mode that y ou w ant the rem ote controlle r to store. Press the button as shown be low while the air condit ioner is operating.
17 EN • Adjust the a ir flow direction proper ly . Failure to do so could cause dis comfort and make an uneven room temperature distr ibution. • Adjust the ver tical ai r flow using the remote co ntroller . • Adjust th e horizontal air flow using the remo te controller.
18 EN This air condit ioner is equipped with an automatic r estar ting fun ction which allows the air cond itioner to re sume without the u se of the remote contr oller under the operating settings in the ev ent of a power shutdown. Operation resumes without warn ing 3 minutes af ter pow e r is restored .
19 EN A utomatic Operation As shown in Figure 1, Automatic Operation mode selects the operation b ased on the r oom temperature da ta when operation begins. The oper ation mode is se lected again af ter the compr essor has re mained stopp ed f or 15 minu tes.
20 EN Maintain r oom temperature at a co mf ortable le vel Clean the air filter s Clogged air filte rs impair the perfor mance of the ai r conditioner. Clean them every two weeks. Never open doo rs and windows mo re than ne cessar y T o keep cool or warm air in the room, ne v er open doors and windo ws more than necessar y .
21 EN Cleaning of indoor unit and remote contr oller When not us ing the uni t for at least 1 mont h (1) P erf orm fan operation for 3 to 4 hours to dr y the inside of the un it. • If a high temperature sett ing is used with cooling operation, fan operation is performed.
22 EN Preparation: 1 Open the moving pa nel. Pull the handles on the bottom of the r ight and left sides, and open the m oving panel until it is hor izontal. 2 Be sure to alw a ys gr asp the han dles when open ing the mo v ing panel. (The mo ving panel ca nnot be remo v ed.
23 EN Three-minute pr otection f e ature A protection feature is provided that prevents the air conditioner from being ac tivated f or approximately 3 minutes when it is restarted immediately afte r operation or wh en the power supply switch is set to on.
24 EN TR OUBLESHOO TING CA UTION If any of the following conditions occur, stop the air conditione r immediately , turn off the ma in power switch and contact the dealer . • The indicators f lash at shor t inter vals (5 Hz). Reset the circu it breaker 2 to 3 minutes after the power main switch is tur ned off.
25 EN Before asking for servicing or repairs, check the follo wing points. These are n ot defects. Condensatio n for ms on the bac k of the ind oor unit. • Condensat ion on the b ack of the indoor un it is automati cally collected and drained out. Indoor unit o r outdoor unit ma kes a strange nois e.
26 EN Before asking for servicing or repairs, check the follo wing points. These a re not d efects. The PURE indica tor (Oran ge) turns on. • The indicator may turn on if th e moving panel is not fir mly close d.
27 EN Before asking for servicing or r epairs, check the follo wing points. TR OUBLESHOO TING (Remote Controller) The remote cont roll er does not oper ate correctl y . Symptoms Causes P ossible Solution The operating mo de switches. • Check whethe r the MODE ind icated on the displa y is A UTO .
28 EN • These specifica tions are subjec t to change without notice for the pur pose of inco rp orating technical improvements. SPECIFICA TIONS Ty p e Reverse cycle, Split typ e Model Indoor Unit Ou.
29 EN The specified a ir-conditioning p erformance is based on the data deter mined under the following conditions. For cool i ng For heat i ng Air inlet te mpe rature °C Indoor coil assembly Outdoor.
EG44550301 Info rma tion according to EMC Directive 200 4/108/EC (Name of the man uf acturer) T OSHIB A CARRIER CORPORA TION (Address, city , countr y) 336 T adehara, Fuji-shi, Shizuok a-k en, 416-8521 J apan (Name of the Impor ter / Distributor in EU) T oshiba Carrier UK Ltd.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Toshiba RAS-07PKVP-E è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Toshiba RAS-07PKVP-E - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Toshiba RAS-07PKVP-E imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Toshiba RAS-07PKVP-E ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Toshiba RAS-07PKVP-E, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Toshiba RAS-07PKVP-E.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Toshiba RAS-07PKVP-E. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Toshiba RAS-07PKVP-E insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.