500/800 Instruction M anual ON/OFF Operation Firing rate: CF500: 1.75 – 5.50 GPH CF800: 3.00 – 8.00 GPH Motor voltage: 120 / 60 Hz std. MODEL MODEL MODEL MODEL MODEL CF 500/ Oil Burner Thank you for purchasing a Beckett burner . With proper care and regular maintenance, it will provide years of trouble-free service.
2 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Please . . . r ead this page first Hazard definitions The following will be used throughout this manual to bring attention to hazards and their risk factors, or to special information.
3 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Contents Please . . . read this page first ................ 2 Pre-installation checklist ........................... 4 Mount the burner ........................................
4 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Pr e-installation checklist ❏ Combustion air supply • The burner requires combustion air and ventilation air for reliable operation.
5 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner ❏ V erify firing rate • Refer to appliance manufacturer’ s instructions (if avail- able) for firing rate and nozzle selection.
6 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Mount the bur ner ❏ Mount flange(s) on air tube • This section does not apply to burners with welded flanges. • Do not install air tube on burner . • For non-pressure firing flange , refer to Figure 3 : Install gasket (item a ) and flange (item d ).
7 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Figure 5 - Nozzle line assembly in burner Legend c acorn nut d fastener e Indicator adjusting plate f Secondary adjusting plate Figure 6 - Adjusting plate assembly ❏ Install nozzle line assembly • Insert the nozzle line assembly into the burner air tube.
8 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Connect fuel line(s) Install the oil lines using the following guidelines. Failure to comply could lead to equipment damage and present a risk of severe personal injury , death or substantial property damage due to leakage of oil and potential fire hazard.
9 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner T able 3 – Fuel unit gearset capacities ❏ Burner fuel flow • One-pipe systems – See Figure 7 for the fuel flow path. • Oil supply connects to one of the fuel unit inlet ports.
10 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Figure 9a – T ypical wiring Wir e the bur ner — R7184 Install the burner and all wiring in accordance with the National Electrical Code and all applicable local codes or requirements.
11 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Wir e the bur ner — R8184 (alter nate) Install the burner and all wiring in accordance with the National Electrical Code and all applicable local codes or requirements. W ire the burner in compliance with all instructions provided by the appliance manufacturer .
12 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner ❏ Z dimension • Should be set per these instructions (see page 7). The acorn nut ( Figure 6 , item c , page 7) should never be loosened once the Z dimension is initially set.
13 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Star t the bur ner Do not proceed unless all prior steps in this manual have been completed. Failure to comply could result in se vere personal injury , death or substantial property damage.
14 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Maintenance and ser vice The burner must be serviced at least annually by a qualified service technician to assure continued reliable operation. Operation and adjustment of the burner requires technical knowledge and the use of combustion test instruments.
15 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Replacement par ts Figure 10 – Adjustable mounting plates for CF500/CF800 Item Part name Description Part number 1 Air tub.
U.S.A.: P . O. Box 1289 • Elyria, Ohio 44036 • 800-645-2876 • 440-327-1060 • F AX 440-327-1064 Canada: R. W . Beckett Canada, Ltd. • 430 Lair d Road • Guelph, Ontario, N1G 3X7 • 800-665-.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Beckett CF 500/800 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Beckett CF 500/800 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Beckett CF 500/800 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Beckett CF 500/800 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Beckett CF 500/800, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Beckett CF 500/800.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Beckett CF 500/800. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Beckett CF 500/800 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.