RESIDENTIAL BURNERS Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner: Please read and carefully follow all instructions provided in this manual regarding your responsibilities in caring for your heating equipment.
2.
3 AFII Burner Manual T o the Owner : Thank you for purchasing a Beckett burner for use with your heating appliance. Please pay attention to the Safety W arnings contained within this instruction manual.
4 Gener al Inf or ma tion Section: General Information Hazard De fi nitions Within the boundaries of the hazard warning, there will be information presented describing consequences if the warning is not heeded and instructions on how to avoid the hazard.
5 AFII Burner Manual Inspect/Pr epar e Installa tion Site Clearances to Burner and Appliance Provide space around burner and appliance for ease of service and maintenance. Check the minimum clearances against those shown by the appliance manufacturer and by applicable building codes.
6 HB 6 slot HC 9 slot HD 6 slot HE 9 slot Any accumulation of soot or debris in chimney offsets should be removed Any obstructions such as a protruding joint or a piece of broken tile wedged in the chimney should be removed. No other appliance connection should be made to the same fl ue pipe.
7 AFII Burner Manual the burner or provide a sealed enclosure for the burner and supply it with its own combustion air supply . Direct/Sidewall V enting Application When sidewall venting appliances, carefully follow appliance and power venter instructions for installation and wiring.
8 On the outside of the home use a 90° elbow pointed downward with a 1/4 ” mesh screen over its opening. The air inlet elbow must be located above the snow line and in such a way as to prevent leaves and/or other debris from blocking the air fl ow .
9 AFII Burner Manual Figure 6. – Mounting Burner in Appliance 3 G P H 1 5 0 - 2 0 0 P S I 3 4 5 0 R P M 4 G P H GPH 1 0 0 - 1 5 0 10 0-15 0 P S I PS I 3 4 5 0 3450 R P M R P M B Y - P A S S IN L E T A 2 E A -6 5 2 0 A2EA-6520 N O.2 & L I G H T E R F U E L E x c l u s i v e l y f o r B e c k e t t N O.
10 Bur ner Controls GeniSys Model 7505 Control Wiring Figure 7 - 7505 Control Features Thermostat / Operating and Limit Control Compatible Welded Relay Protection Limited Recycle Limited Reset 3 Statu.
11 AFII Burner Manual the igniter remains on for 10 additional seconds to ensure fl ame stability . Run : The fl ame is sustained until the call for heat is satis fi ed. The burner is then sent to Motor-Off Delay , if applicable, or it is shut down and sent to Standby .
12 Figure 8a. – Interrupted ignition, valve-on delay only (no motor-off delay) Figure 8b. – Interrupted ignition, valve-on delay and motor-off delay SAFETY AND OPERA TING LIMITS LIMIT L1 L2 (VL V).
13 AFII Burner Manual RECYCLE. If the fl ame is lost while the burner is fi ring, the control shuts down the burner , enters a 60 second recycle delay , and then repeats the above ignition sequence. If fl ame is lost three times in a row , the control locks out to prevent cycling with repetitious fl ame loss due to poor combustion.
14 Star t Up Bur ner and Set Combustion Set the thermostat substantially above room temperature. Close the line voltage switch to start the burner . If the burner does not start immediately you may have to reset the safety switch of the burner primary control.
15 AFII Burner Manual P erfor m Regular Maintenenance The following guidelines are provided for routine maintenance. Replace the oil supply line fi lter . The line fi lter cartridge must be replaced to avoid contamination of the fuel unit and nozzle.
16 T able 4 - Nozzle Flow Rate by Size Nozzle fl ow rate U. S. gallons per hour of No. 2 fuel oil when pump pressure (psig) is: Nozzle size (rated at 100 psig) 125 psi 140 psi (factory std.) 150 psi 175 psi 200 psi 0.40 0.45 0.47 0.49 0.53 0.56 0.50 0.
17 AFII Burner Manual Figure 10a. HLX Air Tube SK9639 Figure 1 1a. Electrode Settings-HLX Air T ube Combinations 1-1/2” 15/32” 3/32” 5/32” 1/4” 5/32” Nozzle face to back of head S top Screw Do NOT overtighten Clamp Screw Figure 1 1b. Electrode Settings-FBX Air T ube Combinations SK9461 SK8263 Figure 12.
18 HLX Firing Rate Stop Screw AFII 85 AFII 100 AFII 150 0 0.40-0.65 0.5-0.65 0.75-1.00 1 - 0.6-0.75 0.85-1.10 2 - 0.65-0.80 0.95-1.15 3 0.60-0.75 0.65-0.90 0.95-1.20 4 - 0.75-0.95 1.10-1.25 5 0.70-0.85 0.85-1.00 1.15-1.35 6 - 0.95-1.10 1.15-1.40 7 - - 1.
19 AFII Burner Manual For best performance specify genuine Beckett replacement parts Item Description Kit No. 14 Housing ass’y: AFII 85 & 100 AFII 150 51584U 51476U 15 Motor: 1/7 hp, 3450 rpm, 1.
USA: P .O. Box 1289 ● Elyria, Ohio 44036 Canada: R.W . Beckett Canada, Ltd. ● Unit #3, 430 Laird Road ● Guelph, Ontario N1G 3X7 www .beckettcorp.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Beckett AFII è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Beckett AFII - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Beckett AFII imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Beckett AFII ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Beckett AFII, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Beckett AFII.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Beckett AFII. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Beckett AFII insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.