Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner: y Please read and carefully follow all instructions provided in this manual regarding your responsibilities in caring for your heating equipment. y Contact a professional, quali fi ed service agency for installation, start-up or service work.
2 Contents Burner Application Scope and Intended Use ........... 2 Prepare Before Installing ............................................ 3 Speci fi cations ..................................................................... 3 Notice Special Requirements.
3 12 Vdc ADC Burner Manual Section: Prepare Before Installing Owner ’ s Responsibility Incorrect installation, adjustment, and use of this burner could result in severe personal injury , death, or substantial property damage from fi re, carbon monoxide poisoning, soot or explosion.
4 Figure 1. T ypical Burner Nameplate T able 1. Low Firing Rate Baf fl e Head T ype Low Firing Rate Baf fl e (if speci fi ed) F0 up to 0.65 gph F3 up to 0.85 gph F4 or F6 up to 0.90 gph T able 2. Air Tube Combination (A TC) Codes Firing Rate GPH Head Static Plate Size A TC Codes for Usable Air T ube Lengths: (‘A ’ in inches see Fig.
5 12 Vdc ADC Burner Manual 10 11 6 8 1 2 7 4 9 3 5 4 90 ° Contacts to be parallel with horizontal center line within 2°. Electrode gap to be centered with nozzle center .
6 Figure 4. ‘Z’ Dimensions Using Gauge SK9787 Section: Nozzle Assembly Maintenance B. Check/Adjust Electrodes Check the electrode tip settings. Adjust if necessary to comply with the dimensions shown in Figure 2 . T o adjust, loosen the electrode clamp screw and slide/rotate electrodes as necessary .
7 12 Vdc ADC Burner Manual For oil supply system speci fi cations for tanks not mounted on machines, carefully follow the pump manufacturer ’s literature and the latest edition of the National Fire Protection Association (NFP A) 31 standard. Pumps with automatic bypass do not require a bypass plug.
8 Section: Burner Wiring Figure 6A. T ypical Wiring For Constant Duty Ignition - With No Primary Control Figure 6B. T ypical Wiring For Interrupted Ignition - With No Primary Control 30A FUSE IGNITER .
9 12 Vdc ADC Burner Manual Figure 6C. T ypical Wiring with 7556 Primary Safety Control Section: Drive Component Maintenance Driv e Component Maintenance A.
10 Section: Drive Component Maintenance B. Pump Maintenance General Pump Information Important information - Long or oversized inlet lines may require the pump to operate dry during initial bleeding period. In such cases, the priming may be assisted by injecting fuel oil in the pump gear set.
11 12 Vdc ADC Burner Manual Section: Start Up Burner & Set Combustion Explosion and Fire Hazard Failure to follow these instructions could lead to equipment malfunction and result in heavy smoke emission, soot-up, hot gas puff-back, fi re and asphyxiation hazards.
12 Section: Maintain & Service Burner Professional Service Required Incorrect installation, adjustment, and use of this burner could result in severe personal injury , death, or substantial property damage from fi re, carbon monoxide poisoning, soot or explosion.
13 12 Vdc ADC Burner Manual T roubleshooting Oil burners that are designed for use on road maintenance equipment are built to take temperature extremes, vibration, and rough handling.
14 Section: T roubleshooting T able 4. Troubleshooting Chart Symptom Possible Cause Oil Not Igniting If the burner is not igniting, the burner motor , drive coupling, and oil pump are operating and oil is fl owing to the nozzle through the solenoid valve, check the following possibilities.
15 12 Vdc ADC Burner Manual 1 2 3 4 5 6 7 8 9 12 10 11 13 14 15 16 18 19 17 21 20 22 23 R eplacement P ar ts Illustration # Description Part# 1 DC Motor n/a 2 Blower Wheel 2999U 3 Coupling 2140501 4 A.
The R. W . BECKETT CORPORA TION (“Beckett”) warrants to persons who purchase its “Products” from Beckett for resale, or for incorporation into a product for resale (“Customers”), that its equipment is free from defects in material and workmanship.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Beckett ADC è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Beckett ADC - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Beckett ADC imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Beckett ADC ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Beckett ADC, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Beckett ADC.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Beckett ADC. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Beckett ADC insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.