Subject to technical changes OPERA TING INSTRUCTIONS BECKER AR 4201 - ( O) (GK 415) portable VHF Transceiver B e c k e r F l u g f u n k w e r k G m b H B a d e n A i r p a r k , B 1 0 8 D - 7 7 8 3 6 R h e i n m ü n s t e r ( G e r m a n y ) T e l .
© Copyright by Becker Flugfunkwerk Issue 05/00 Article No. 890.375-071.
Blank Operating Instructions Page 40 Issue 05/2000 Table of contents Important 3 Introduction 3 Safety information 4 Additional information 5 General information 6 Controls and indicators 7 p Switchin.
p Setting the IC level 24 p Calibrating the temperature sensor 24 p Setting addressable storage locations 1 to 99 24 p Setting the temperature display in °C or °F 25 p Switching on the scan function.
Operating Instructions Page 38 Issue 05/2000 Important Carefully read these operating instructions right through before attemp - ting to operate the portable VHF station. Keep these operating instructions carefully. They contain important sa - fety and operating instructions for the portable VHF station.
The CAUTION, WARNING and NOTE highlights have the following meanings: Failure to comply, or incorrect compliance, with these instructions or procedures can lead to in - juries or fatal accidents. Failure to comply, or incorrect compliance, with these instructions or procedures can lead to damage to equipment.
Operating Instructions Page 36 Issue 05/2000 Additional information l A speech test is to be performed before startup and it should be no - ted that if the speech test is carried out close to the portable VHF sta - tion the results may be positive even if the antenna cable is broken or short-circuited.
General information Carrying case and transceiver together form a portable VHF station. The easily-portable VHF station can be used, for example, for mobile and fi - xed operations on airfields or landing strips. It an also be used in hot air balloons, for ferrying aircraft or or recovery of gliders.
Servicing and operation of lead-acid batteries Lead-acid batteries are to be charged immediately after use. Disch - arged lead-acid batteries are to be charged for approximately 16 hours at 1/10 of the rated capacity. A few basic rules need to be observed in the handling of lead-acid batte - ries, to maintain their service life over several years.
Operating instructions Connect the antenna and the mike to the corresponding connection jacks. o Switching on the unit Switch on the portable VHF station using the ON/OFF switch (rotate vo - lume control clockwise).
T echnical data Supply voltage range 10 V . . . 32 V DC Normal power supply voltage 13.75 V DC Power consumption at 13.75 V - “Standby” reception mode typ. 70mA - Reception mode typ. 500mA - T ransmission mode typ. 2,5 A T emperature range - 20° C .
CH 99 (bottom line) Indicates the storage channel CH indication flashes If the initiated storage operation (bottom line) is not completed by pressing the store key F (bottom line) Indication that the selected storage channel is not occupied V 1 1.7 (bottom line) Indication of supply voltage All indicating segment Supply voltage £ 10.
o Channel priority ON/OFF switch (option upwarts serial no.: 46) Call up function SF 18 using the MDE key . The following displays appe - ars : T op line SF 18 Bottom line CS channel number Using the kHz (steps of 1) or MHz (steps of 10) switch, select the de - sired channel.
o T ransmit/receive mode Set the frequency in the preset display and press the exchange key . Ro - tate the VOL control to the centre position. Operate the transmit button and call the other station. Hold the micro - phone close to the lips for optimum speech transmission.
o Setting the “channel end” scanning range (if funtion SF8 ac - tivated) Call up function SF 14 using the MDE key . The following displays appe - ar : T op line SF 14 Bottom line CS channel number Using the kHz (steps of 1) or MHz (steps of 10) switch, select the end channel at which the scan function is to stop.
o Flashing of the LCD If the power supply for the portable VHF station drops below 10.5 V , the display begins to flash. This flashing indicates, when operating on batte - ries for example, that the batteries require recharging. In prac-tice the display begins to flash in the transmit mode because this is when the po - wer consumption is greatest.
o Inhibiting the frequency setting (channel selection only) Call up function SF 10 using the MDE key . The following displays appe - ar : T op line SF 10 Bottom line 0 or 1 Select the required function using the kHz key and store the function by pressing the STO key .
o Mode 1 (standard mode) The last displayed active and preset frequencies appear in the LCD dis - play . The preset frequency (bottom line) is set using the MHz and kHz fre - quency selector switches. When the exchange key is pressed, a change from the active to the pre - set frequency occurs.
o Setting the IC level Call up the SF4 function using the MDE key . The following displays ap - pear : T op line SF 4 Bottom line 00 to 63 The IC level can be changed upwards or downwards using the kHz switch. The set value is stored by pressing the STO key .
o Scan function If the scan function is activated in the equipment configuration, pressing the STO key changes from the channel selection mode to the scan function. In the scan function, the frequency appears in the top line of the display and the associated channel with the preset CS is shown in the bottom line.
l In the service mode the portable VHF station operates indepen - dent-ly of the settings on the control panel, on the frequency which was last set as the active frequency .
Service mode (equipment configurations) The service mode is meant to enable to set the equipment configuration. The following settings can be changed or set : SF 1 Setting the switch-on threshold of t.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Becker Designed AR 4201 - ( O) (GK 415) è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Becker Designed AR 4201 - ( O) (GK 415) - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Becker Designed AR 4201 - ( O) (GK 415) imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Becker Designed AR 4201 - ( O) (GK 415) ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Becker Designed AR 4201 - ( O) (GK 415), ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Becker Designed AR 4201 - ( O) (GK 415).
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Becker Designed AR 4201 - ( O) (GK 415). Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Becker Designed AR 4201 - ( O) (GK 415) insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.