Manuale d’uso / di manutenzione del prodotto USDT 2004B del fabbricante Thermo Products
Vai alla pagina of 10
USDT 2004B Installation and User’s Guide Introduction General Information 2 Installation Collector Sensor 3 Control Box 5 Power Connection 6 Display Window 6 Operation Basic Operation of Digital Dis.
2 Introduction Note: The information supplied in this manual is for guidance only - no part of this may be used for any agreement, whether express or implied, or to form any contract. Thermo Technologies reserves the right to change specifications without prior notice.
3 INSTALLATION Note: This installation procedure is for guidance only, and the installer should verify its suitability. Make sure that the solar system is physically installed, manually tested, and ready for controlled operation. he following safety precautions is strongly recommended: 1.
4 l Collector sensor (red cable with protective terminal box): Either push into a thermowell, (sensor pocket), which is soldered or riveted directly to the manifold (vacuum tubes). Alternately, strap the sensor to the collector outlet pipe or the absorber ( flat plate collectors) that projects from the collector housing.
5 Undo the screw at the top of the housing. The control elec tronics are mounted on the enclosure cover. The controller enclosure can be screwed to the wall with cable entry grommets pointed downwards. Use the supplied plastic bridges to secure power and sensor cables.
6 ower Connections: A small blade screwdriv er may be used to fasten miniaturized terminal block screws while the corresponding wire is inserted. NOTE 1: Always disconnect the controller from power supply before opening the housing. NOTE 2: The controller should be properly grounded.
7 ò Push selection key once to enter the advanc ed (Par or *Men) mode. Once in selected mode, press one more time to select the parameter in that mode. Selected parameter blinks allowing the user to modify it. You can modify the selected parameter while the middle window blinks by pressing the ï or ð ke y.
8 Par Using the navigation key ^_ allows you to select the desired parameter while you are in the program mode. Press the selection key ò once to select the parameter in the window. Selected parameter blinks allowing you to modify it. You can modify the selected parameter while the middle window blinks by pressing the ï or ð key.
9 Ma nual Operation Mode This mode allows the user to manually turn the pump on or off. AUTO The above display indicates that the unit is working in automatic mode. The pump starts at a temperature difference of 15 o F and runs as long as ? T is above 7 o F.
10 T roubleshooting In general, all of the settings in the menus Par and Men and the terminal should first be checked if there is a malfunction. Malfunction, but "realistic" temperature values: • Check program number. It should be “0” (zero) for 2004B unit.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Thermo Products USDT 2004B è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Thermo Products USDT 2004B - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Thermo Products USDT 2004B imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Thermo Products USDT 2004B ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Thermo Products USDT 2004B, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Thermo Products USDT 2004B.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Thermo Products USDT 2004B. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Thermo Products USDT 2004B insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.